Must be able to
secure the fan to
building structure or
fan-rated outlet box
You may need a
friend to help you.
Check box to see
fan weight
If you are unfamiliar
with wiring, use a
qualied electrician.
Know your wiring
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Assess ceiling angle
30 inches
from blade tip
to nearest wall
or obstruction
Assess location
Standard Downrod
1
for ceilings 8-10 feet high
Shorter Downrod
2
for fans installed close to ceiling
Longer Downrod
3
for ceilings 10 feet or higher
Select a downrod length
7 feet
from bottom
edge of blade
to the oor
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
w.1 - To reduce the risk of re, electrical shock, or
personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for
fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent
warning device, such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects
in between rotating fan blades.
CAUTIONS
c.1 - All wiring must be in accordance with national and
local electrical codes ANSI/NFPA 70. If you are unfamiliar
with wiring, use a qualied electrician.
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
(Ungrounded)
Black
Blue
Using the orange wire
connectors from
the hardware bag, connect
the black wire (ungrounded)
from the ceiling to the black
and the blue wires from the
fan. Connect the white wire
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
• Push the motor reversing switch
rmly left or right to ensure that
it is engaged.
• Check the circuit breaker to
ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 7.
• Check the plug connection in
the switch housing.
Excessive wobbling
• Tighten all of the blade and
blade iron screws until they
are snug.
• Use the provided balancing
kit and instructions to balance
the fan.
Noisy Operation
• Tighten the blade and blade
iron screws until they are snug.
• Check to see if any of the
blades are cracked. If so, replace
all of the blades.
2-Year Energy Star Light Kit Warranty
The Hunter Fan Company, Inc. makes the following
warranty to the original user or consumer purchaser of
each Hunter Energy Efcient Light Kit:
If your Hunter Energy Efcient Light Kit fails at any time
within two years after the date of sale due to a defect in
material or workmanship, labor to repair the defect will
be provided free of charge at our nearest service center
or our service department in Memphis, TN. You will be
responsible for all labor costs after this two-year period.
This warranty is voided if this product is not purchased in
the U.S.A. or Canada.
This warranty excludes and does not cover defects,
malfunctions or failures of any product which were
caused by repairs by persons not authorized by us, use of
parts or accessories not authorized by us, mishandling,
improper installation, modications or damage to the
light xture while in your possession, or unreasonable
use, including failure to provide reasonable and
necessary maintenance. IN NO EVENT SHALL HUNTER
FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR
INCIDENTAL DAMAGES.
SOME STATES DO NOT ALLOW LIMITATION ON HOW
LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION
OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS
MAY NOT APPLY TO YOU.
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,
AND YOU MAY ALSO HAVE OTHER RIGHTS THAT VARY
FROM STATE TO STATE.