erly on an uneven surface. ALWAYS
place this humidifi er on a fi rm, level,
and water resistant surface. ALWAYS
place the humidifi er at least six (6) inches
away from walls and heat sources such
as stoves, radiators, or heaters.
2. ALWAYS place the humidifier in an
area that is out of the reach of children.
3. Before using the humidifier, extend
the cord and inspect for any signs of
damage. DO NOT use the product if
the cord has been damaged.
4. This product has a polarized plug
(one blade is wider than the other) as
a safety feature. This plug will fi t into a
polarized outlet only one way. If the plug
does not fi t fully into the outlet, reverse
the plug. If it still does not fi t, contact a
qualifi ed electrician. DO NOT attempt to
defeat or override this safety feature.
5. ALWAYS UNPLUG AND EMPTY
the humidifi er when it is not in operation or while it is being cleaned.
6. DO NOT tilt or move the humidifi er
while it is in operation. Never move the
humidifi er while there is water in the
tank. Empty the water tank, turn off,
and unplug the unit before moving.
7. In addition to routine maintenance
which may be required, this humidifi er
requires seasonal cleaning. Refer to and
follow CLEANING THE HUMIDIFIER AND THE WATER TANK instructions.
8. This unit is designed to be used with
distilled and/or tap water. DO NOT add
scented oils, perfumes, or fragrance additives to the water.
Thank you for purchasing The Care Free
Humidifi er Evaporative Humidifi er by
Hunter Fan Company. Please read and
save these instructions to receive the
maximum benefit and performance
from your humidifi er.
®
How the Care Free® Humidifi er
Evaporative Humidifi er Works
The Care Free® Humidifi er Evaporative Humidifi er
has a unique patented design with several
innovative features:
• Exclusive EnduraWickter – The patented self-pumping paper wick
has an outer layer which disperses water to
the upper and outer areas of the wick to
ensure consistent moisture distribution. This
helps to reduce buildup of mineral residue
on the lower part of the wick and retain
performance for signifi cantly longer than
traditional paper wicks.
plastic parts and the fi lter have built-in antimicrobial properties to inhibit the growth
of bacteria, mold and fungi that may affect
these parts.
NOTE: This product contains antimicrobial
properties which are built-in to inhibit the
growth of bacteria which may affect the
plastic and fi lter in the humidifi er. These
properties do not extend to the water,
humidifi ed air or users. Conduct routine
cleaning and maintenance based upon use
and individual conditions.
• No White Dust – The Care Free® Humidifi er Evaporative Humidifi er produces
no white dust that can settle on furniture
or be inhaled.
NOTE: You may notice mineral deposits
accumulating in the tank base or on the
Humidifi er Parts
fi lter. This is normal and does not affect
performance. If you would like to clean
these deposits away, please see CLEANING
THE HUMIDIFIER AND WATER TANK.
Power/Speed Control: Tu rns the humidifi er
‘ON’ and ‘OFF’. The power should always be
off before unplugging the humidifi er, moving
the humidifi er, or refi lling the water tank.
Refi ll Light: The red light will be illuminated to
signal you that the humidifi er has automatically
turned off and the water tank needs to be
refi lled.
Adjustable Humidistat: Enables you to set
a desired maximum humidity level. Once this
level is reached, the unit will shut off until the
humidity level drops.
NOTE: The humidifier may not be running
because the humidistat setting may need to
be adjusted.
Desired Humidity Light: The green light will
be illuminated when the humidity in the room
has reached the level that you selected with the
adjustable humidistat knob.
NiteGlo™ Night Light Control: Tu r n s t h e
night light ‘ON’ and ‘OFF’. The night light
can be turned on even if the humidifi er fan is
turned off.
1. Remove The Care Free® Humidifier
Evaporative Humidifi er from its packaging.
Read and Save the Instructions.
2. Place the humidifier on a hard, flat,
water resistant surface. Always place the
humidifi er at least six (6) inches away from
walls and sources of heat.
3. Lift the main housing to confirm that
the fi lters are placed upright in the slots.
Replace the main housing. (See Figure 1.)
4. Remove the water tank and take it
to the sink or tub to fi ll.
5. Turn the tank upside down and
unscrew the tank cap by turning it counterclockwise. Fill the water tank with cool
water and replace the tank cap (Never use
hot water). Be sure not to overfi ll the tank
as water damage may occur to furniture
or fl ooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBIL-
ITY FOR DAMAGE TO PROPERTY CAUSED
BY WATER SPILLAGE.
6. Carry the tank back to the humidifi er. Turn the tank upright and place it on
the humidifi er. Be sure that the tank is
seated properly in the base. If the tank is
properly located on the base, you will see
air bubbles fl owing up into the tank.
7. With the power control knob in the
‘OFF’ position, plug the humidifi er into the
wall.
CAUTION: Never plug in the Humidifi er
while your hands are wet as Electric
Shock could occur.
8. Place the full tank on the unit and
allow the water to fi ll the bottom tray. The
water is at the proper level in the bottom
tray when the tank stops bubbling. Set the
unit to the desired speed.
9. Use the power/speed control knob
to turn the humidifi er ‘ON’ by selecting a
speed setting.
10. You can choose the desired humidity out put by adjusting the Adjustable Hu mi dis tat
knob. In a very dry room, the “HI” setting
should be used to quickly achieve a comfortable level of humidity. Once the room
is comfortable, you can turn the Adjustable Humidistat down. Selection of your
desired humidity level is a per son al choice
and you may have to adjust the dial to fi nd
the level where you feel most comfortable. To begin with, we sug gest you try a
middle location between the lowest and
the maximum setting. Then, adjust the
level to suit your needs.
11. When the humidity reaches the level you
have set, the “Desired Humidity” light will
be illuminated. The humidifi er will not
output humidity while the humidity in the
room is at the selected humidity level. The
“Desired Humidity” light will stay on un til
the humidity changes. When the hu mid i ty
in the room drops below the se lect ed level,
the humidifi er will cy cle on again and the
“Desired Humidity” light will go off.
Only for models with Automatic Shut-off
12. When the water tank is empty, the humidifi er will automatically shut itself off. The
red light will be illuminated, indicating that
the water tank needs to be refi lled.
13. Follow REFILLING THE WATER TANK
directions. Once the water tank is refi lled,
the Refi ll Light will not be illuminated.
Only for models with a
NiteGlo™ Night Light
14. Use the control to turn the night light off
and on. The night light can be operated
even if the humidifi er fan is turned ‘OFF’.
1. When the water tank level is low, turn
the humidifi er ‘OFF’, and unplug.
2. Remove the tank and take it to the sink
or tub to refi ll.
3. Turn the tank upside down and unscrew the tank cap by turning it counterclockwise. Empty the tank, refi ll with fresh
cool water (never use hot water), and replace
the tank cap. Be sure not to overfi ll the tank
as water damage may occur to furniture or
fl ooring due to spillage.
HUNTER WILL NOT ACCEPT RESPONSIBILITY
FOR DAMAGE TO PROPERTY CAUSED BY
WATER SPILLAGE.
Cleaning the Humidifi er and the Water Tank
Many regions have hard water with high
concentrations of minerals. When water
evaporates from The Care Free
Evaporative Humidifi er, minerals may be left
behind. These minerals can form a hard white
scale which can be removed by following the
cleaning instructions. The frequency of cleaning
due to mineral build up can vary depending upon
the quality of water you may have.
Refer to Figure 1 for part names.
1. Turn the humidifier ‘OFF’ and unplug
the unit.
2. Lift the main housing and remove
the fi lters. The motor is attached to the
main housing. Do not place the motor
near water. Do not use a wet towel on
the motor or motor housing as electrical
shock may occur.
3. At the end of the season, discard the
paper wick and order Hunter replacement
wicks. Call customer service at 1-800313-3326 or see our Web page at http:
//www.hunterfan.com.
®
Humidifier
4. Carry the tank back to the humidifier.
Turn the tank upright and place it on the
humidifi er. Be sure that the tank is seated
properly in the base. If the tank is properly
located on the base, you will see air bubbles
fl owing up into the tank.
5. Place the full tank on the unit and allow
the water to fi ll the bottom tray. The water is
at the proper level in the bottom tray when
the tank stops bubbling. Set the unit to the
desired speed.
4. Remove the water tank from the base
and empty any water that is left in the tank.
Soak the base in a mixture of one (1) gallon
of water and eight (8) ounces of vinegar for
20 minutes.
5. After soaking, wipe the base with a soft
cloth or sponge to remove any mineral build
up. Rinse with clean water several times. If
you are planning on storing the humidifi er,
be sure the base is completely dry.
6. Fill the water tank with one (1) gallon of water and eight ounces of undiluted
white vinegar. Replace the tank cap and
shake the tank vigorously until all interior
surfaces of the tank have been exposed to
the water/vinegar mixture.
7. Empty the tank of the water/vinegar
mixture. Rinse it several times with clean
water and then replace the tank cap. If you
are planning on storing the humidifi er, dry it
inside and out, leaving the cap off to allow
the tank to completely dry. Continue to clean
the other parts of your humidifi er.