Hunter 30750 Owner's Manual

Model 30750
Replacement Filter Information
Model 30750
Pre-Filter
30901
www.hunterfan.com
42995-01 05/08/2006 © 2006 Hunter Fan Company
41782-01.pmd 6/7/05, 2:33 PM1
Table of Contents
Safety Instructions ..................................................................................................3
Introduction ............................................................................................................3
Description of Air Filtration System
How the Air Purifier Works............................................................................4
Air Purifier Components ................................................................................4
Display and Control Keys ..............................................................................5
Operation
Initial Operation .............................................................................................6
Filter Life Counters ........................................................................................8
Locking/Unlocking the Keypad .....................................................................8
Resetting the Air Purifier ............................................................................... 9
Using the Ionizer ............................................................................................ 9
Controlling the Backlight ...............................................................................9
Air Purifier Maintenance
Cleaning Your Air Purifier............................................................................ 10
Changing the Pre-Filter ................................................................................10
Cleaning the Filter ........................................................................................11
Obtaining Replacement Filters..................................................................... 13
Troubleshooting
Problem and Solutions .................................................................................14
Technical Support .........................................................................................14
Warranty Information ......................................................................................... 15
41782-01.pmd 6/7/05, 2:33 PM2
SAFETY INSTRUCTIONS
IMPORTANT!
READ ALL INSTRUCTIONS BEFORE USING THIS AIR PURIFIER.
1. This air purifier is designed for use on a flat level floor and may not work properly on
an uneven floor. ALWAYS place the air purifier on a firm level floor. ALWAYS place the air purifier at least six (6) inches away from walls and heat sources such as stoves, radiators, or heaters.
2. Place the air purifier in an area that is out of the reach of children.
3. Before using the air purifier, extend the cord and inspect for any signs of damage. DO NOT
use the product if the cord has been damaged.
4. This product has a polarized plug (one blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If the plug still does not fit, contact a qualified electrician. DO NOT attempt to defeat or override this safety feature.
5. ALWAYS UNPLUG the air purifier while it is being cleaned.
6. DO NOT move or tilt the air purifier while it is in operation. Turn off and unplug before moving.
7. DO NOT immerse the air purifier in water at any time because permanent damage will occur. To properly clean your air purifier, follow the instructions in the Maintenance section of this manual (pg. 10).
READ AND SAVE ALL INSTRUCTIONS.
Introduction
Thank you for purchasing the PermaLife™ Air Purifier from Hunter Fan Company. You have purchased our latest development in portable air purification which has been designed to im­prove the quality of the air that you breathe. The following innovative features are included in your Hunter Air Purifier.
High Particulate Efficiency: The cleanable filter will remove 99.5% of 0.5 micron particles
from the air that passes through the filter.
• Odor Removal: The activated carbon pre-filter helps remove odors such as cooking, smoke,
and pet smells from the air. It also traps lint, hair, and other large particles to help extend the life and performance of the cleanable filter.
• Ionizer: The ionizer improves the quality of air in the room by releasing negative ions into
the air that attract positively charged dust, smoke, and pollen particles.
• Quiet: The air purifier has been designed to operate quietly and efficiently. You can choose
among three speeds to best meet your needs at different times.
•Filter Counters: Filter maintenance is critical to the performance of the air purifier. To help
you determine when to change or clean the pre-filter and cleanable filter, the unit has built in life counters that keep track of the life remaining of each filter.
• NiteGlo™ Light: Your air purifier display has a backlight that is continuously lit as long as
there is power to the unit. You can choose to turn the backlight off or on.
3 42995-01
41782-01.pmd 6/7/05, 2:33 PM3
Description of Air Filtration System
How the PermaLife™ Air Purifier System Works
As the air is pulled into the purifier, the activated carbon pre-filter absorbs odors and catches large particles. Then, the air travels through the PermaLife™ Cleanable Filtration System where the smaller particles are collected. Then, the ionizer releases negative ions into the air that attract positively charged dust, smoke, and pollen particles. Finally, the clean purified air is released back into the room.
Dust & Irritants
Pollen & Allergens Odors Bacteria Pet Hair & Dander
Fig. 1 - Illustration of the Air Filtration System
Air Purifier Components
BASE
Fig. 2 - Air Purifier Components
Carbon
Pre-filter
PermaLife™
Cleanable
Filtration System
99.5% – .5 Microns
CLEANABLE FILTER
Ionizer
PRE-FILTER
FRONT GRILL
41782-01.pmd 6/7/05, 2:33 PM4
Description of Air Filtration System
Display and Control Keys
The display and control keys allow for easy operation of the air purifier.
UP/DOWN KEYS: Adjusts the blower speed and turns the unit on and off.
PRE-FILTER RESET: Resets the Carbon Pre-Filter Life Counter.
FILTER RESET: Resets the Cleanable Filter Life Counter.
IONIZER KEY: Turns the ionizer on and off.
CLEANABLE
PRE-FILTER RESET KEY
FILTER RESET KEY
FILTER LIFE COUNTER
BLOWER SPEED
IONIZER INDICATOR
UP/DOWN KEYS
IONIZER KEY
CLEANABLE FILTER INDICATOR
CARBON PRE-FILTER INDICATOR
Fig. 3 - Air Purifier Control Area and Alpha-numeric Display
41782-01.pmd 6/7/05, 2:33 PM5
PRE-FILTER LIFE COUNTER
5 42995-01
ANIMATED BLOWER
KEYPAD LOCKED INDICATOR
Operation
Initial Operation
This section provides basic instructions on the use of your air purifier. After following these initial directions, please continue reading this booklet to learn how to operate the more advanced features of your air purifier.
Basic Operation of the Air Purifier:
1. Take the air purifier out of the box and remove the clear plastic protective bag. Place the unit on a firm level floor.
2. Before turning on the air purifier, you need to confirm that the filters are firmly in place and have not become loose during shipping. To check the filters, first open the front grill. Release the front grill by placing your fingers under the handle on the grill and pull forward, then up. Refer to Figs. 4 and 5.
HANDLE
Fig. 4
3. Next, check the cleanable filter by pressing firmly on all four corners of the filter to ensure that it is fully inserted into the filter opening.
4. The carbon pre-filter is mounted inside the front grill with hook tape. Confirm that it properly covers the grill vents. You may notice a few black particles com­ing off the pre-filter. Those particles are part of the odor-removing activated car­bon and will be collected on the filter during use.
41782-01.pmd 6/7/05, 2:33 PM6
PULL FORWARD, THEN UP
Fig. 5
Operation
5. Place the front grill back onto the unit. First, line up the tab on the bottom of the grill with the recess on the purifier base and then push the top of the grill forward until it is closed. Refer to Figs. 6 and 7. NOTE: This unit will not operate unless the grill is in the correct position.
LINE UP TAB WITH RECESS IN BASE
TA B
RECESS
Fig. 6
Fig. 7
6. Plug the unit into a 120V electrical outlet and press the UP key. The air puri­fier will start with a low blower speed.
7. Use the UP/DOWN keys to adjust the blower speed to the desired level (0 = Off, 1 = Sleep, 2 = Active, 3 = Turbo Clean). Refer to Fig. 8.
Fig. 8
7 42995-01
41782-01.pmd 6/7/05, 2:33 PM7
Operation
Filter Life Counters
The pre-filter and filter are critical to the proper operation of the air purifier. To help you know when to clean or change the filters, your Hunter Air Purifier has Filter Life Counters that will monitor the percentage of life your filter has left. Although the exact life of the filters depends on the environment, the table below gives typical usage times of the filters.
Table 2: Typical Usage Times of the Filters
Filter Type Typical Usage
Activated Carbon Pre-Filter 1400 hours
Cleanable Filter 2800 hours
The display shows the percentage of life left since the counter was reset. NOTE: The per- centage level drops in 5% increments.
The values of the Pre-Filter and Filter Life Counters are stored in the air purifier’s memory. The unit may be unplugged and moved or stored without losing the Pre-
Filter and Filter Counter values.
To properly track filter usage, the Pre-Filter and Filter Life Counters should be reset each time the filters are changed or cleaned. Refer to Changing the Pre-Filter (pg. 10) or Clean­ing the Filter (pg. 11) for instructions on how to reset the counters.
Locking/Unlocking the Keypad
Once you enter the desired speed, you may want to lock the keypad to prevent accidental changing of the speed. When the keypad is locked, all keys will be disabled. If you press a key, the Keypad Locked Indicator will be displayed on the screen for 1-2 seconds.
To Lock or Unlock the Keypad:
1. To lock the keypad, press and hold the UP/DOWN keys simultaneously for 2-3 seconds. The Keypad Locked In­dicator will appear on the display. Refer to Fig. 9. After releasing the keys, the Keypad Locked Indicator will dis­appear.
2. To unlock the key pad, press and hold the UP/DOWN keys simultaneously for 2-3 seconds. The Keypad Indi­cator will disappear and the keypad will be functional.
41782-01.pmd 6/7/05, 2:33 PM8
Fig. 9
Operation
Resetting the Air Purifier
In the unusual situation that the unit or the display is exhibiting erratic behavior, you may want to reset the air purifier. If you still have problems after resetting the air purifier, please contact Hunter for additional assistance (refer to Technical Assistance, pg. 14).
To Reset the Air Purifier:
1. Unplug the unit for at least 30 seconds.
2. Plug the unit back in.
Using the Ionizer
Using the ionizer improves the quality of air in the room. Negative ions are released into the air and positively charged dust, smoke, and pollen particles are attracted to the negative ions. These particles settle out of the air and can be vacuumed up during normal cleaning. These particles are also more easily captured by the cleanable filter as they pass through the PermaLife™ Cleanable Filtration System. To ensure the best air circulation in the room, we recommend that you place your air purifier six (6) inches away from any walls.
To turn the ionizer on or off:
1. To turn the ionizer on, press the IONIZER key. The Ion­izer Indicator will appear on the display. Refer to Fig 10.
2. To turn the ionizer off, press the IONIZER key. The Ion­izer Indicator will disappear.
Fig. 10
Controlling the Backlight
Your air purifier display has a backlight that is continuously lit as long as there is power to the unit. The backlight may be turned off.
To turn the backlight off or on:
Press the PRE-FILTER RESET and FILTER RESET keys at the same time. NOTE: Do not hold down the keys for longer than 2 seconds. This may reset a
and
41782-01.pmd 6/7/05, 2:33 PM9
filter counter.
9 42995-01
Air Purifier Maintenance
Cleaning Your Air Purifier
Proper maintenance of your Hunter Air Purifier will help ensure years of trouble free service.
Follow these steps to properly maintain your air purifier:
1. Approximately every 90 days, the outside of the unit should be cleaned with a soft, damp cloth.
2. If needed, the front grill can be removed from the unit and cleaned with soapy water. Simply remove the pre-filter before exposing the grill to water.
3. Follow the instructions in Changing the Pre-Filter and Cleaning the Filter (pgs. 10 and
11) to determine when and how to replace or clean the filters.
NOTES:
•The air purifier must be unplugged during the cleaning process.
• Be sure the unit is completely dry before plugging in and using.
•Never immerse unit in water.
Changing the Pre-Filter
When the Pre-Filter exceeds 1400 hours (refer to Filter Life Counters for additional infor­mation, pg. 8), the Pre-Filter Life Counter will display 0% life remaining and the Pre-Filter indicator will flash as a reminder that you should replace the pre-filter. To maintain proper odor-removing capability and overall filtration performance, the pre-filter should be changed every 1400 hours (approximately 3 months of use). If necessary, the pre-filter can be changed more often. Proper maintenance of the pre-filter will help extend the life of the cleanable filter. Refer to Obtaining Replacement Filters (pg. 13) if you need help find­ing replacement filters.
To change the pre-filter and reset the Pre-Filter Life Counter:
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill. Place your fingers under the handle on the grill and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).
3. The pre-filter is attached to the inside of the grill with hook tape. Pull gently on the pre-filter to remove it. Refer to Fig. 11 (pg. 11).
4. If needed, use a soft damp cloth to wipe off the grill.
5. Install the new pre-filter by placing it in the grill and pressing gently on the pre­filter so that it adheres to the hook tape. You may notice a few black particles coming off the pre-filter. Those particles are part of the odor-removing activated carbon and will be collected on the filter during regular use.
42995-01 10
41782-01.pmd 6/7/05, 2:33 PM10
Air Purifier Maintenance
PRE-FILTER
HOOK TAPE
Fig. 11
HOOK TAPE
6. Place the front grill back onto the unit. First, line up the tab on the bottom of the grill with the recess on the purifier base and then push the top of the grill forward until it is closed. Refer to Figs. 6 and 7 (pg. 7). NOTE: This unit will not operate unless the grill is in the correct position.
7. Plug in the air purifier.
8. Finally, reset the Pre-Filter Counter by pressing the PRE-FILTER RESET key for 2 seconds. The Pre-Filter Counter will return to 100% and the Pre­Filter indicator will stop flashing.
Cleaning the Filter
The PermaLife™ Filtration System uses a cleanable filter that never has to be changed, only cleaned. When the filter exceeds 2800 hours (approximately 4 to 6 months of use), the Filter Life Counter will display 0% life remaining and the Filter indicator will flash (refer to Filter Life Counters for additional information, pg. 8). This is a reminder that you should check the filter and clean if necessary. The proper time to clean the filter depends on usage and the environment. Use the following list to help determine if the filter should be cleaned:
• Compare the color of the filter to the color coded chart on the inside of the housing. If the filter color matches the darkest color on the chart, you should clean the filter.
• If you notice a decrease in air output or an increase in noise at any time during normal operation, the filter may be clogged. Clean the filter to return to normal operation.
To clean the filter and reset the Filter Life Counter:
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill. Place your fingers under the handle on the grill and pull forward, then up. Refer to Figs. 4 and 5 (pg. 6).
11 42995-01
41782-01.pmd 6/7/05, 2:33 PM11
Continued
Loading...
+ 23 hidden pages