Hunter 28568 User Manual

Page 1
Dual Function
Dual Function
Dual Function
Bowl Light Kit
Bowl Light Kit
Bowl Light Kit
Owner’s Guide and Installation Manual
Manual De Propietario
English Español
Form# 43550-01 20100610 ©2010 Hunter Fan Co.
Page 2
Table Of Contents
1 • Installing the Light Kit on a Ceiling. . 4
2 • Installing the Light Kit on a Removable
Switch Housing . . . . . . . . . . . . . . . . . . . 6
3 • Installing the Light Kit on a Non-
Removable Switch Housing. . . . . . . . 8
4 • Installing the Light Kit on the Hunter
Original . . . . . . . . . . . . . . . . . . . . . . . . . 10
5 • Installing Bulbs, Chain, and Globe. . . 11
6 • Troubleshooting. . . . . . . . . . . . . . . . . . . . 12
Welcome
Your new Hunter® light kit is an addition to your home or office that will provide comfort and performance for many years. is installation and operation manual gives you complete instructions for installing and operating your light kit.
We are proud of our work. We appreciate the opportunity to supply you with the best products available anywhere in the world.
Before installing your light kit, for your records and warranty assistance, record information from the carton and Hunter nameplate label.
Cautions and Warnings
READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, install this light fixture only on Hunter® fan types A through Z. Note: e fan type can be found on the ceiling fan package or on the nameplate label located on top of the motor housing of the ceiling fan.
• To avoid possible electrical shock, before installing light fixtures, disconnect the power by turning off the circuit breakers both to the outlet box and to its associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
• Connect house wiring to the fan before attaching the light fixture to the fan.
• All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.
© 2010 Hunter Fan Company
43550-01 • 06/10/10 • Hunter Fan Company
Page 3
Installation Methods of Hunter® Ceiling Fans Type A-Z
Removable Switch Housing
Your ® light kit can be installed in one of four ways. e steps in this manual include instructions for all four installation methods: Installation directly on the ceiling, installation on fans with a removeable switch housing, fans with a non-removeable switch housing, and e Hunter Original.
Preparing the Light Kit:
1. Disconnect power by turning off the circuit breakers both to the outlet box and to its associated wall switch location.
2. e shade cover plate comes in a choice of decorative finishes. In addition, the cover plate for the ceiling­mounted light has no hole in the side; the cover plate for the fan-mounted light has a hole in the side. Choose the cover plate that applies to your decorating preference and your mounting preference.
Non-removable Switch Housing
e Hunter Original
43550-01 • 06/10/10 • Hunter Fan Company
Directly onto ceiling
Page 4
1 • Installing the Light Kit on the Ceiling
1. If you are replacing an existing light fixture, disconnect and remove the old fixture and mounting bracket. Leave the wires coming from the outlet box exposed.
2. Pre-install the two #8-32 screws, two corresponding washers, and two #8-32 nuts on the hanger bracket. Tighten nuts securely. Note: e hanger bracket should be positioned so that the two #8-32 screws are coming down and the green grounding screw is going up towards the ceiling.
3. Using the screw holes located on the electrical box, secure the hanger bracket to the electrical box by threading the screws through the slotted holes in the hanger bracket. Tighten screws. Note: e screws for installing the hanger bracket to the electrical box should be installed in the opposite direction as the screws for installing the ceiling plate cover to the hanger bracket.
4. Locate the metal (uncoated) ground wire from the light fixture and the supply ground wire coming out of the electrical box. Connect the metal ground wire and the supply ground wire underneath the green ground screw on the hanger bracket. Tighten the green ground screw as needed.
5. Connect the white wire from the light fixture to the white supply wire coming out of the ceiling. Connect the black wire from the light fixture to the black supply wire coming out of the ceiling. Secure all wire connections using approved wire connectors. To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist the wire connector clockwise until tight.
6. Spread the electrical splices so that the black wires are on one side of the outlet box and the white wires are on the other side.
#8-32 Screws
Nuts
Step 2
Ground
Screw
#8-32 Scews
Steps 3-4
CAUTION: Be sure no bare metal wires or wire strands are visible after making
the connections.
7. Align the holes in the cover plate with the #8-32 screws that were pre-installed on the hanger bracket. Raise the light fixture and insert the screws through the two holes in the cover plate.
8. Install the decorative nuts on the end of each of the #8-32 screws. Tighten securely.
WARNING: Improper installation could cause the light fixture to fall, or result in
electrical shock or personal injury.
43550-01 • 06/10/10 • Hunter Fan Company
Decorative
Nut
Steps 5-8
Page 5
1 • Installing the Light Kit on the Ceiling (contintued)
9. Install the included CFL light bulbs into the lamp sockets.
10. Remove the lower chain extension from the light fixture by unhooking it from the breakaway connector. Leave the breakaway connector in place on the upper chain.
11. read the light pull chain through the hole in the center of the glass bowl. Place the glass bowl on the threaded rod until flush against the metal disc.
12. Place a cover plate (with no side hole) up against the glass bowl. read the light pull chain through the center opening of the cover plate.
13. read the light pull chain through the finial and screw the finial onto the threaded rod until tight.
14. e installation is complete and you can restore power to the light fixture.
Steps 11-14
Finial
43550-01 • 06/10/10 • Hunter Fan Company
Cover
Plate
Light Pull
Chain
Page 6
2 • Installing the Light Kit on a Removable Switch Housing
1. Unscrew the three screws from the upper switch housing. Disconnect the 9-pin plug connectors. Remove the lower switch housing.
2. Push the plug button from inside the lower switch housing to remove the plug button and switch housing cap.
NOTE: Save the plug button and switch housing cap should you
choose to remove the light fixture in the future.
3. Unscrew the nut and washer from the threaded rod at the top of the light kit to remove the mounting plate and replace it with the smaller switch housing cover included with the light fixture.
4. Feed the two wires from the light fixture through the center hole in the lower switch housing.
5. Screw the threaded rod of the light fixture into the center of the lower switch housing until you feel resistance. Unscrew the light fixture slightly until the holes of the light fixture are aligned with the holes in the lower switch housing.
6. Finish attaching the light fixture to the lower switch housing using the two attachment screws included. Securely tighten the two screws.
7. Install the nut and washer inside the upper switch housing onto the threaded rod from the upper light housing.
Removable Switch Housing
9-Pin Plug
Connector
Screw
Threaded Rod
Switch Housing Cover (included with the light fixture)
Light Fixture
Nut
Washer
Lower
Switch
Housing
Attachment
Screws
Steps 3-6
WARNING: Improper installation could cause the light fixture to fall.
43550-01 • 06/10/10 • Hunter Fan Company
Steps 1-2
Lower Switch
Housing
Plug Button
Page 7
2 • Installing the Light Kit on a Removable Switch Housing (Continued)
7. Remove the wire connectors from the two wires in the switch housing labeled “Connect Light Here” or “For Light Use.”
To connect the wires, hold the bare metal leads together and place a
wire connector over them, then twist the wire connector clockwise until tight.
Connect the black wire with a white stripe from the switch housing
to the black wire from the light kit. Connect the white wire from the switch housing to the white wire from the light kit. Secure all wire connections using wire connectors.
CAUTION: Be sure no bare metal wires or wire strands are visible after
making the connections.
8. Reconnect the 9-pin plug connector.
9. Reinstall screws to reattach the lower switch housing to the upper switch housing.
10. Go to the instructions for Installing the Bulbs, Chains, and Globe.
Plug Connector
Step 8
Lower Switch Housing
Wires
and Wire
connectors
Step 7
Housing Assembly Screw
Plug Connector Detail
43550-01 • 06/10/10 • Hunter Fan Company
Page 8
3 • Installing the Light Kit on Fans With Non-Removable Switch Housing
1. Uninstall the two attachment screws from the switch housing cover.
2. Remove the plug or screw from the center of the switch housing cover.
3. read the switch housing cover onto the upper light housing. Align the screw holes in the upper light housing with the screw holes in the switch housing cover. Install the nut and washer onto the threaded rod from the light kit to secure the switch housing cover.
4. Remove the wire connectors from the two wires in the switch housing labeled “Connect Light Here” or “For Light Use.” One wire is white and the other wire is black with a white stripe.
5. Feed the two wires from the switch housing through the threaded rod in the upper light housing.
6. To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist the wire connector clockwise until tight.
Connect the black wire with a white stripe from the switch housing to
the black wire from the light kit. Connect the white wire from the switch housing to the white wire from the light kit. Secure all wire connections using wire connectors.
7. Align the threaded screw holes in the switch housing cover with the threaded holes in the switch housing. Attach the switch housing cover and light fixture to the switch housing using the included attachment screws.
CAUTION: Be sure no bare metal
wires or wire strands are visible after making the connections.
Steps 1-2
Switch
Housing
Cover
Non-Removable Switch
Housing
Attachment
Plug
Switch
Housing
Cover
Screw
Nut
Washer
Screw
Hole
WARNING: Improper installation
could cause the light fixture to fall.
Wires
and Wire
Step 7
connectors
43550-01 • 06/10/10 • Hunter Fan Company
Attachment
Screw
Light Fixture
Steps 3-6
Page 9
3 • Installing the Light Kit on a Non-Removable Switch Housing (cont.)
8. Attach the light fixture to the switch housing with the two screws included with the light fixture, aligning the holes in the light fixture, switch housing cover, and switch housing.
9. Securely tighten the two screws.
10. Go to the instructions for Installing the Bulbs, Chains, and Globe.
Wires
and Wire
connectors
Step 8
43550-01 • 06/10/10 • Hunter Fan Company
Page 10
4 • Installing the Light Kit on the Hunter Original
1. Uninstall the two screws from the switch housing plate. NOTE: Save the switch housing cap should you choose to remove the light
fixture in the future.
2. Remove the wire connectors from the two wires in the switch housing labeled “Connect Light Here” or “For Light Use.” One wire is white and the other wire is black wire with a white stripe. read the two wires through the hole in the center of the light fixture.
3. Unscrew the nut and washer from the threaded rod at the top of the light kit to remove the mounting plate and replace it with the smaller switch housing cover included with the light fixture.
4. To connect the wires, hold the bare metal leads together and place a wire connector over them, then twist the wire connector clockwise until tight.
Connect the black wire with a white stripe from the switch housing to
the black wire from the light kit. Connect the white wire from the switch housing to the white wire from the light kit. Secure all wire connections using wire connectors.
CAUTION: Be sure no bare metal wires or wire strands are visible after
making the connections.
5. Attach the light fixture to the switch housing with the two screws, included with the light fixture, aligning the holes in the fixture, switch housing cover, and switch housing.
6. Securely tighten the two screws.
7. Go to the instructions for Installing the
Bulbs, Chains, and Globe.
Screw
Step 1
Hunter Original
Switch
Housing
Plate
WARNING: Improper installation
could cause the light fixture to fall, or result in electrical shock or personal injury.
Switch
Housng
Cover
(included
with the
light
fixture)
Light
Fixture
Step 5
10
43550-01 • 06/10/10 • Hunter Fan Company
Step 4
Page 11
5 • Installing Bulbs, Chain, and Globe
1. First install included CFL medium base bulbs.
2. read the fan pull chain through the hole in the metal disc. en,
thread the fan pull chain through the hole in the center of the glass bowl.
3. read the light pull chain through the hole in the center of the glass
bowl.
4. Place the cover plate up against the glass bowl. Align the holes in the
cover plate and metal disc.
5. read the fan pull chain and light pull chain through the appropriate
holes.
6. read the light pull chain through the finial and screw the finial onto
the threaded rod end until tight.
CFL Bulb
(included)
For Light Bulbs
Pull Chain
Breakaway
Connector
Metal Rod
Metal Disc
Glass Bowl
Cover Plate
Finial
11
43550-01 • 06/10/10 • Hunter Fan Company
Page 12
6 • Troubleshooting
Troubleshooting
Light does not come on.
1. Make sure bulbs are installed properly.
2. Make sure breakers or fuses are on.
3. Verify that the light power lead is connected at the ceiling. Refer to your ceiling fan manual for locating assembly and wiring.
Glass rattles.
1. Make sure the glass globe is secure.
If you need parts or service assistance, please call 888-830-1326 or visit us at our Web site at http://www.hunterfan.com.