Your new Hunter® light kit is an addition to your home or oce that
will provide comfort and performance for many years. is installation
and operation manual gives you complete instructions for installing
and operating your light kit.
We are proud of our work. We appreciate the opportunity to supply
you with the best products available anywhere in the world.
Before installing your light kit, for your records and warranty assistance,
record information from the carton and Hunter nameplate label.
Cautions and Warnings
• READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING
INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, install this light xture only on
Hunter® fan types A through Z. Note: e fan type can be found on
the ceiling fan package or on the nameplate label located on top of
the motor housing of the ceiling fan.
• To avoid possible electrical shock, before installing light xtures,
disconnect the power by turning o the circuit breakers both to
the outlet box and to its associated wall switch location. If you
cannot lock the circuit breakers in the o position, securely fasten a
prominent warning device, such as a tag, to the service panel.
• Connect house wiring to the fan before attaching the light xture to
the fan.
• All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualied electrician.
Installation Methods of Hunter® Ceiling Fans Type A-Z
Removable Switch Housing
Your ® light kit can be installed in one of three
ways. e steps in this manual include instructions for
all three installation methods: Installation on fans with
removeable switch housings, fans with non-removeable
switch housings, and e Hunter Original.
Preparing the Light Kit:
1. Disconnect power by turning o the circuit breakers
both to the outlet box and to its associated wall switch
location.
Non-removable Switch Housing
e Hunter Original
43526-01 • 12/30/09 • Hunter Fan Company
3
Page 4
1 • Installing the Light Kit on Fans With Removable Switch Housings
1. Unscrew the three screws from the upper switch housing. Disconnect
the 9-pin plug connectors. Remove the lower switch housing.
2. Push the plug button from inside the lower switch housing to remove
the plug button and switch housing cap.
NOTE: Save the plug button and switch housing cap should you
choose to remove the light xture in the future.
3. Remove the nut and washer from the threaded rod on the top of the
light kit.
4. Ensure the gasket is in place on top of the light kit. Feed the two wires
from the light kit up through the center hole in the gasket and the
lower switch housing.
5. Screw the lower switch housing onto the threaded rod on the light
kit until you feel resistance. en, unscrew the lower switch housing
slightly to align the holes in the light kit and the gasket with the screw
holes of the lower switch housing.
6. Install the nut and washer onto the threaded rod from the light kit to
secure the lower switch housing onto the light kit.
7. Finish attaching the light kit to the lower switch housing using the
included screws and the lock washers on the red tag. e gasket
should now be sandwiched securely between the light kit assembly
and the switch housing assembly.
WARNING: Improper installation could cause the light xture to fall.
Screw
Steps 1-2
Removable Switch Housing
9-Pin Plug
Connector
Lower Switch
Housing
Plug Button
Step 6
4
43526-01 • 12/30/09 • Hunter Fan Company
Threaded
Rod
Gasket
Wires
Nut
Washer
Page 5
1 • Installing the Light Kit on Fans With Removable Switch Housings (Continued)
8. Remove the wire connectors from the two wires in the switch housing
labeled “Connect Light Here” or “For Light Use.”
To connect the wires, hold the bare metal leads together and place a
wire connector over them, then twist the wire connector clockwise until
tight.
Connect the black wire with a white stripe from the switch housing to
the black wire from the light kit. Connect the white wire from the switch
housing to the white wire from the light kit. Secure all wire connections
using wire connectors.
9. Reconnect the 9-pin plug connector.
and Wire
connectors
Wires
CAUTION: Be sure no bare metal wires or wire strands are visible after
making the connections.
10. Reinstall the screws removed in Step 1 to reattach the lower switch
housing to the upper switch housing.
11. Go to the instructions for Installing the Bulb and Globe.
Step 8
5
43526-01 • 12/30/09 • Hunter Fan Company
Page 6
2 • Installing the Light Kit on Fans With Non-Removable Switch Housing
1. Uninstall the two attachment screws from the switch housing cover.
2. Remove the plug or screw from the center of the switch housing cover.
3. Ensure the gasket is in place on the light kit mounting plate. Remove the
nut and washer from the threaded rod on the top of the light kit.
4. read the switch housing cover onto the threaded rod from the light kit
until you feel resistance. e gasket should now be sandwiched securely
between the light kit and the switch housing cover. en, unscrew the
switch housing cover slightly until the holes in the switch housing, gasket,
and switch housing cover are all aligned.
5. Install the nut and washer onto the threaded rod from the light kit to
secure the switch housing cover onto the light kit.
6. Remove the wire connectors from the two wires in the switch housing
labeled “Connect Light Here” or “For Light Use.” One wire is white and the
other wire is black with a white stripe.
To connect the wires, hold the bare metal leads together and place a wire
connector over them, then twist the wire connector clockwise until tight.
Connect the black wire with a white stripe from the switch housing to
the black wire from the light kit. Connect the white wire from the switch
housing to the white wire from the light kit. Secure all wire connections
using wire connectors previously removed.
7. Attach the light kit and switch housing cover to the switch housing using
the included screws and the lock washers on the red tag.
8. Go to the instructions for Installing the
Bulb and Globe.
Steps 1-2
Non-Removable Switch
Housing
Switch
Housing
Cover
Plug
CAUTION: Be sure no bare metal
wires or wire strands are visible
after making the connections.
WARNING: Improper installation
could cause the light xture to fall.
43526-01 • 12/30/09 • Hunter Fan Company
Switch
Housing
Cover and
Gasket
Switch
Housing
Cover
Wires
and Wire
connectors
Attachment
Screw
Step 6
Nut
Washer
Steps 3-5
6
Page 7
3 • Installing the Light Kit on the Hunter Original
1. Uninstall the two screws from the switch housing plate.
NOTE: Save the switch housing cap should you choose to remove the light
xture in the future.
2. Remove the wire connectors from the two wires in the switch housing
labeled “Connect Light Here” or “For Light Use.” One wire is white and the
other wire is black wire with a white stripe.
To connect the wires, hold the bare metal leads together and place a wire
connector over them, then twist the wire connector clockwise until tight.
Connect the black wire with a white stripe from the switch housing to
the black wire from the light kit. Connect the white wire from the switch
housing to the white wire from the light kit. Secure all wire connections
using wire connectors.
CAUTION: Be sure no bare metal wires or wire strands are visible after
making the connections.
3. Ensure that the gasket is resting on the light kit mounting plate. Attach the
light kit and to the switch housing using the included screws and the lock
washers on the red tag.
4. Go to the instructions for Installing the Bulb and Globe.
Screw
Step 1
Hunter Original
Switch
Housing
Plate
WARNING: Improper installation
could cause the light xture to
fall, or result in electrical shock or
personal injury.
Screw and
Washer
Steps 2-3
7
43526-01 • 12/30/09 • Hunter Fan Company
Page 8
4 • Installing the Bulb and Globe
1. First, install the included CFL medium-based bulb.
2. Attach the globe and grill to the light kit using the three screws
included.
3. e installation is complete and you can restore power to the ceiling
fan.
Bulb
8
43526-01 • 12/30/09 • Hunter Fan Company
Globe
and Grill
Screw
CFL Bulb
(included)
Page 9
5 • Troubleshooting
Light does not come on.
1. Make sure bulbs are installed properly.
2. Make sure breakers or fuses are on.
3. Verify that the light power lead is connected at the ceiling. Refer to
your ceiling fan manual for locating assembly and wiring.
Globe rattles.
1. Make sure the globe is secure.
If you need parts or service assistance, please call
888-830-1326 or visit us at our Web site at
http://www.hunterfan.com.
Hunter Fan Company
7130 Goodlett Farms Pkwy. # 400
Memphis, Tennessee 38016
is Light Fixture Weighs 4 lbs. Printed in China
9
43526-01 • 12/30/09 • Hunter Fan Company
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.