Hunter 27208 User Manual

Universal Fan and
Universal Fan and
Universal Fan and
Light Remote Control
Light Remote Control
Light Remote Control
Form# 44092-01 20101215 ©2010 Hunter Fan Co.
Owner’s Guide and Installation Manual
English
1 • Welc ome
Table of Contents
1 • Welcome ..............................................................2
2 • Installation Preparation ............................... 3
3 • Receiver Installation ......................................4
4 • Transmitter Installation ............................... 7
5 • Programming the Remote .........................8
6 • Operation ............................................................ 8
7 • Troubleshooting ...........................................10
8 • Warranty ........................................................... 11
© 2010 Hunter Fan Company
44092-01 • 12/15/10 • Hunter Fan Company
Read and Save these Instructions
Caution: Risk of Electrical Shock!
All wiring must be performed in accordance with national and local electrical codes. If you are unfamiliar with the
wiring codes, you should use a qualied electrician.
To avoid overheating and possible damage to other equipment, do not install to control a receptacle, motor operated appliance, or transformer-supplied appliance. Use only to control one ceiling fan with or without a light
xture.
Ratings: 120 VAC, 60 Hz,1.0 Amp Fan Receiver Weight: 6 oz. 300 Watts incandescent light
2
2 • Installation Prep aration
Notes:
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
2. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from the one the
receiver is connected to.
• Consult the dealer or an experienced radio/TV technician for help.
3. For use only with electrically reversible ceiling fans rated at 1.0 amp or less,
44092-01 • 12/15/10 • Hunter Fan Company
and fan incandescent light kits rated at 300 watts or less.
4. Not for use with shaded-pole motors, Hunter 42” Low Prole fans, and
Hunter Baseball fans. Not recommended for use with the Hunter Original®. For Hunter Original® series fans, use Hunter control model numbers 27187, 22691, or 27189.
5. Medium and Low fan speeds are determined by the control and thus may vary from the factory settings due to normal motor variations.
6. For use with Hunter Hanging Systems (excludes Hunter Original) on at
ceilings or angled ceilings with a pitch up to 34°.
7. Not for use in applications where the fan does not have a wall switch.
Any changes or modications to this equipment not expressly approved by Hunter Fan Company will void the user’s authority to operate the equipment.
USE THE PULL CHAIN SWITCH TO SET THE FAN SPEED TO THE HIGH POSITION BEFORE INSTALLATION. DO NOT USE THE PULL CHAIN TO CHANGE THE FAN SPEED AFTER INSTALLATION, AS DAMAGE TO YOUR FAN OR REMOTE MAY RESULT. THE SPEED OF THE FAN SHOULD ONLY BE CHANGED BY THE HUNTER CONTROL!!
BEFORE YOU INSTALL THIS CONTROL:
3
3 • R eceiver Installation
1. USE THE PULL CHAIN SWITCH TO SET THE FAN SPEED TO THE HIGH POSITION BEFORE INSTALLATION. DO NOT USE THE PULL CHAIN TO CHANGE THE FAN SPEED AFTER
INSTALLATION, AS DAMAGE TO YOUR CEILING FAN OR UNIVERSAL CONTROL MAY RESULT.
THE SPEED OF THE FAN SHOULD ONLY BE CHANGED BY THE HUNTER CONTROL!!
2. Set the ceiling fan light kit to the ON position before installation.
Installation Instructions:
1. Install the ceiling fan according to its instructions, up to the point of making the electrical connections. Connect receiver to
ceiling fan according to the mounting types shown on the next page. Determine your ceiling fan mounting type from the images on Pages 4-5. Most installations will be one of these ve types.
2. If the fan is already installed, turn the power OFF at the main electrical panel. Reverse the installation procedure according to the fan instructions, to the point of disconnecting the fan wiring. Connect the receiver to the ceiling fan according to the mounting type as shown on Pages 4-5.
IMPORTANT! If your ceiling fan light kit is using incandescent bulbs, then slide the CFL / INC switch to the INC position. (Fig. 2) If your ceiling fan light kit is using compact uorescent light bulbs (CFL), then slide the CFL / INC switch to the CFL
position. NOTE: When the switch is in the CFL position, the dimming feature is disabled, and you will not be able to dim the light bulbs. This feature is to protect both your bulbs and your receiver as CFL bulbs are not able to dim and will malfunction if dimming is attempted.
Low Prole Style I (Figure 1): Secure receiver to the fan plate above the motor with UL-listed cable ties (not included).
Connect wiring as shown in Figure 6. Extend antenna through one of the ceiling plate openings (approximately 3–6˝).
NOTE: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire leaving a minimum of 6 inches remaining. Restrip the fan lead wires 1/2 inch. Place remaining excess wire into the ceiling electrical box
as needed.
BEFORE INSTALLING THE CONTROL:
4
44092-01 • 12/15/10 • Hunter Fan Company
Cable Tie Routing for Low Prole
Fans (Figs.1 & 3): Insert cable tie through
openings as shown. DO NOT insert the cable
tie through the inside of the receiver. The cable tie can be placed across the length or width of the receiver to best match your fan installation type.
Figure 1
INC CFL
Low
Prole
Style 1
CFL Toggle
Switch
Figure 2
3 • R eceiver Installation
Hands
Antenna
Low
Prole
Figure 3
Low Prole Style II (Figure
3): Secure receiver to the ceiling
mounting bracket with UL-listed cable ties (not included). Connect wiring as shown in Figure 6.
Extend antenna above the ceiling mounting bracket (approximately 3–6˝).
NOTE: Some fans may have considerable excess lead wire. For easier canopy installation, cut the excess wire leaving a minimum of 6 inches remaining. Restrip the fan lead wires 1/2 inch. Place remaining excess wire into the ceiling electrical box as needed.
Style 2
Canopy Hanger (Fig. 4):
Place receiver in canopy. Connect wiring as shown in Figure 6.
Extend antenna through one
of the ceiling plate openings
(approximately 3–6˝).
Fig.
Canopy
44092-01 • 12/15/10 • Hunter Fan Company
Free
4
Hunter Hands-Free™
Canopy: Connect wiring as shown in Figure 6. Place receiver
inside mounting bracket. Extend
antenna above the ceiling
mounting bracket (approximately 3–6˝).
5
Figure 5
Bracket Hanger
Bracket Hanger: Starting
with the antenna wire, slide receiver inside mounting bracket. If a ground wire mounting screw prevents the receiver from sliding into the bracket, move ground wire and screw to an unused hole at the top of the bracket or secure with a canopy mounting screw. The bracket must remain properly grounded. Connect wiring as
shown in Figure 6. Extend antenna above the receiver (approximately 3 – 6˝).
Figure 6
3 • R eceiver Installation
1. Use the 2 large (orange) wire connectors supplied to connect the receiver and house wiring, then use the 3 small (blue) wire connectors supplied to connect
the receiver and ceiling fan wiring. Refer to the Wiring Diagram in Figure 6.
If you are installing the remote with a Hunter Fan, the wire colors in the fan will be as follows:
Light Power = Black with a White Stripe Fan Power = Black Common = White
*These are only the Hunter fan wire colors. Other
brands may use different colors.
2. Be sure the antenna is positioned securely, so it does not interfere with the
ceiling fan motor. Do not modify or damage the antenna wire, as control
performance may be reduced. After securing the receiver, antenna, and
wiring, nish hanging the ceiling fan according to its instructions.
3. Restore power at main electrical panel.
Figure 6
AC
Power
In
Black/Hot (marked “LIVE IN” on red label)
White/Neutral (marked “NEUTRAL IN” on red label)
White (marked “COMMON OUT” on white label)
White*
Black
(“FAN
OUT”)
Black*
Antenna
Red (“LIGHT OUT”)
Black
&
White*
Wiring Diagram
*Hunter fan wire colors. Other brands may use different colors.
6
44092-01 • 12/15/10 • Hunter Fan Company
Common
Fan
Light
4 • Transmitter Install ation
1. Install the included 12-Volt alkaline battery (A23 or equivalent) inside the handheld transmitter.
2. Mount the remote holder over the ceiling fan’s wall switch using the existing wall plate screws. Refer to Figure 8.
3. The transmitter can be placed on the remote holder for convenience or safekeeping.
Figure 8
7
44092-01 • 12/15/10 • Hunter Fan Company
Figure 7
5 • Prog ramming th e Remote
Programming the Remote:
The remote transmitter and remote receiver should already be programmed to work together.
If you want the remote to control a second fan, or you want to re-progam remote:
1. Turn the power to the second fan (or the fan you want to re-program) OFF at the wall switch. Then, turn it back ON.
2. Within 30 seconds, press the 1 (Fan Low) and 3 (Fan High) buttons on the transmitter
together and hold them down for 5 seconds. The LED light on the transmitter will blink 3 times to conrm.
3. The fan’s light will turn OFF and the fan will turn ON at low speed to further conrm the programming has taken effect.
4. Repeat this process to correct interference with other devices, or to program additional fans to this remote.
• If there is any fan in your home you do NOT want programmed to this remote, make sure the power
to that fan is turned OFF at its wall switch while programming the remote.
Fan Operation:
For best fan operation: Start the fan on High (3), and then select the desired speed.
• Press the High (3), Medium (2), or Low (1) speed buttons to turn the ceiling fan ON at the desired
speed.
• Press the fan “0” key to turn the ceiling fan OFF.
8
44092-01 • 12/15/10 • Hunter Fan Company
Fan Low
Fan Off
*Hold down fan speed buttons 1 & 3 together for 5 seconds to program the
remote control
Fan
Medium
Fan High
Figure 9
6 • Operation
Light Operation:
• Turn ON wall switch. The light will turn ON at maximum brightness.
• Press and quickly release either light button on the hand held remote to turn the light OFF or ON.
• After a power outage, the light will turn ON when power is restored. Press and quickly release one of
the light buttons once to turn the light back OFF after a power outage.
• Press and hold either light button for more than 1 second to activate the dimming cycle.
Press to turn the light ON at the maximum level and continue holding down to dim the
light.
Press to turn the light ON at a low level and continue holding down to brighten the light.
Continue to hold the light button to repeat the cycle.
Release the light button when the desired light level is reached.
To turn the light OFF:
Press both of the light buttons & together to begin “Safe Exit Mode.” The LED light on
the transmitter will blink 4 times to let you know it’s starting to turn the light off. The light will
slowly dim down until it’s completely off within 30 seconds. This “Safe Exit” feature provides
you with enough light to leave the room safely.
To turn the light off instantly, press and quickly release either light button or once.
• When the light is turned on again, it will “remember” the brightness level it was at before it
was turned off and resume at that level again.
9
44092-01 • 12/15/10 • Hunter Fan Company
Down Dimmer
*Press both of
the light buttons
& together
to begin “Safe
Exit Mode.” The
LED light on
the transmitter
will blink 4
times to let you
know it’s start-
ing to turn the
light off. The light will slowly dim down until
it’s completely
Up
Dimmer
off.
7 • Tro ubl eshooting
Symptom Possible Causes Solution
1.No functions operate. Main Power not restored. Replace fuse. Turn ON circuit breaker. Turn ON wall switch.
2.Fan clicks when remote buttons pushed, but blades do not move.
3.Fan clicks when remote buttons pushed, but light does not work.
4.Operates only at close range. Signal blocked from reaching
5.Inconsistent operation. Signal partially blocked from
Fan pull chain not set to High. Set fan pull chain to High speed.
Light pull chain not set to ON. Set light kit to ON.
Receiver wiring incorrect. Verify wiring connections.
Transmitter not programmed to receiver in fan.
Battery too weak. Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.
Fan pull chain not set to High. Set fan pull chain to High speed.
Light pull chain not set to ON. Pull light chain to turn ON.
receiver.
Battery too weak. Replace with new, 12-Volt alkaline battery. Refer to “Transmitter Installation”, Section 5.
Interference Re-program the remote to a different frequency by pressing and holding fan speed
reaching receiver.
RF interference. Turn OFF wall switch for 5 seconds, then turn back ON.
Continuing RF interference. Re-program the remote. Refer to “Programming the Remote,” Page 8.
Re-program the remote. Refer to “Programming the Remote,” Page 8.
Extend antenna into ceiling box, or move it for better reception.
buttons 1 & 3 together for 5 seconds. Light on transmitter will blink 3 times. Light will
come on and fan will turn on at low speed to conrm programming is complete.
Extend antenna into ceiling box, or move it for better reception.
10
44092-01 • 12/15/10 • Hunter Fan Company
8 • Warranty
HUNTER FAN COMPANY CONTROL LIMITED WARRANTY
The Hunter Fan Company makes the following limited warranty to the original purchaser of the Control (“Control”): Your
Control is warranted to be free from defects in material and workmanship for a period of one year from the date of sale. If the Control malfunctions or fails within the warranty period due to a defect in material or workmanship we will replace it free
of charge. IF THE ORIGINAL PURCHASER CEASES TO OWN THE CONTROL, THIS WARRANTY AND ANY IMPLIED WARRANTY, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE VOIDED. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE DURATION OF ANY IMPLIED WARRANTY, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IN RESPECT TO ANY CONTROL, IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH CONTROL. This warranty excludes malfunctions or failures which were caused by repairs by persons not authorized by us, mishandling, improper installation, modications, or damage to the Control while in your possession, or unreasonable use. This warranty does
not apply to batteries or to deterioration or damage to the product caused by the use of faulty batteries. To obtain a
replacement, return your Control postage prepaid along with proof of purchase to Hunter Fan Company Service Department at 7130 Goodlett Farms Pkwy. #400, Memphis, Tennessee 38016. IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
11
44092-01 • 12/15/10 • Hunter Fan Company
If you need parts or service assistance, please call 888-830-1326 or visit us at our Web site at http://www.hunterfan.com. Hunter Fan Company 7130 Goodlett Farms Parkway #400 Memphis, Tennessee 38016
Printed in China
Loading...