Hunter 23949 48 User Manual

For Your Records and Warranty Assistance
For reference, also attach your receipt or a copy of your receipt to the manual.
Type 2 ModelsType 2 ModelsType 2 Models
Owner’s Guide and Installation Manual
English Español
Form# 42693-01 20100514 ©2010 Hunter Fan Co.
Welcome
Your new Hunter® ceiling fan is an addition to your home or office that will provide comfort and performance for many years. is installation and operation manual gives you complete instructions for installing and operating your fan.
We are proud of our work. We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world.
Before installing your fan, for your records and warranty assistance, record information from the carton and Hunter nameplate label (located on the top of the fan motor housing).
Table Of Contents
Preparing the Fan Site . . . . . . . . . . . . . . . . . 3
1 • Getting Ready. . . . . . . . . . . . . . . . . . . . . . 6
2 • Installing the Ceiling Plate . . . . . . . . . . 7
3 • Assembling and Hanging the Fan . . . 8
4 • Wiring the Fan . . . . . . . . . . . . . . . . . . . . . 9
5 • Setting the Remote Transmitter
and Receiver . . . . . . . . . . . . . . . . . . . . . . 10
6 • Installing the Canopy and Canopy
Trim Ring . . . . . . . . . . . . . . . . . . . . . . . . . 11
7 • Assembling the Blades. . . . . . . . . . . . . . 12
8 • Completing Your Installation With or
Without a Bowl Light Fixture . . . . . . 13
9 • Operating and Cleaning Your
Ceiling Fan . . . . . . . . . . . . . . . . . . . . . . . . 17
10 • Operating the Remote Control . . . . 18
11 • Troubleshooting . . . . . . . . . . . . . . . . . . 19
Cautions and Warnings
READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION. SAVE THESE INSTRUCTIONS.
• Use only Hunter replacement parts.
• To reduce the risk of personal injury, attach the fan directly to the support structure of the building according to these instructions, and use only the hardware supplied.
• To avoid possible electrical shock, before installing your fan, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
• All wiring must be in accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualified electrician.
• To reduce the risk of personal injury, do not bend the blade attachment system when installing, balancing, or cleaning the fan. Never insert foreign objects between rotating fan blades.
• To reduce the risk of fire, electrical shock, or motor damage, do not use a solid-state speed control with this fan. Use only Hunter speed controls.
© 2010 Hunter Fan Company
2
42693-01 • 05/14/10 • Hunter Fan Company
Preparing the Fan Site
Step 1 - Choose the Fan Site
Proper ceiling fan location and attachment to the building structure are essential for safety, reliable operation, maximum efficiency, and energy savings.
Choose a fan site where:
• No object can come in contact with the rotating fan blades during normal operation.
• e fan blades are at least 7 feet above the floor and the ceiling is at least 8 feet high.
• e fan blades have no obstructions to airflow, such as walls or posts, within 30 inches of the fan blade tips.
• e fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan.
30” From Wall or Nearest Obstruction
7’ Minimum Blades to Floor
8’ Minimum
Ceiling Height
Checklist for Existing Fan Site
If you want to use an existing fan site, complete the following checklist to determine if the site is acceptable and safe for your new Hunter fan. If you cannot check off every item, prepare a new fan site as described on this page.
Fan Support System
Fan attaches directly to building structure.
• Fan support system will hold full weight of the fan and light kit.
Ceiling Hole
• e outlet box clearance hole is directly below the joist or support brace.
Outlet Box
• e outlet box is an UL-approved octagonal 4” x 1-1/2” outlet box (or as
specified by the support brace manufacturer).
• e outlet box is secured to the joist or support brace by wood screws
and washers through the inner holes of outlet box.
• e outer holes of the outlet box are aligned with joist or support brace.
• e bottom of the outlet box is recessed a minimum of 1/16” into
ceiling.
Wiring
• e electrical cable is secured to outlet box by an approved connector.
• Six inches of lead wires extend from outlet box. If your existing fan site is suitable, skip ahead to Section 2 • Installing the
Ceiling Plate.
3
Fan Support System
Fan Support System
Suitable Existing Fan Site
Outlet Box
Wiring
42693-01 • 05/14/10 • Hunter Fan Company
Preparing the Fan Site (continued)
Step 2 - Cut the Ceiling Hole
2-1. Locate the site for the ceiling hole directly below the joist or support brace that
will hold the outlet box and fan.
2-2. Cut a 4” diameter hole through the drywall or plaster of the ceiling. You will use
the hole to install the support brace and outlet box.
Step 3 - Install a Support Brace, If Necessary
Determine if there is a ceiling joist directly above the ceiling hole. If the joist is there,
determine if it is positioned to allow you to recess the outlet box a minimum of 1/16” into the ceiling. If NOT, install a support brace as follows:
3-1. Attach a 2” x 4” support brace between two joists. Position it to allow you to
recess the bottom of the outlet box a minimum of 1/16” into the ceiling.
3-2. Check the support brace to ensure it will support the full weight of the fan and
light kit.
Step 4 - Install the Outlet Box
4-1. Obtain a UL-approved octagonal 4” x 1-1/2” outlet box, plus two #8 x 1-1/2”
wood screws and washers, available from any hardware store or electrical supply house.
4-2. Orient the outlet box so that both the inner and outer holes in the box align
with the joist or support brace.
4-3. Drill pilot holes no larger than the minor diameter of the wood screws (5/64”)
through the inner holes of the outlet box.
4-4. Attach the outlet box directly to the support brace or joist with two #8 x 1-1/2”
wood screws and washers.  e bottom of the outlet box must be recessed a minimum of 1/16” into the ceiling.
Step 5 - Prepare the Wiring
5-1. Make sure the circuit breakers to the fan supply line leads and associated wall
switch location are turned off . If you cannot lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a tag, to the service panel.
5-2. read the fan supply line through the outlet box so that the fan supply line
extends at least 6” beyond the box.
5-3. Attach the fan supply line to the outlet box with an approved connector,
available at any hardware store or electrical supply house.
5-4. Make certain the wiring meets all national and local standards and ANSI/NFPA
70.
You have now successfully prepared your ceiling fan site. For instructions to install your ceiling fan, go to your fan manual and continue with Section 2 • Installing the
Ceiling Plate.
Steps 2 – 3
Step 4
Step 5
CAUTION: All wiring must be in
accordance with national and local electrical codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
4
42693-01 • 05/14/10 • Hunter Fan Company
Installer’s Choice and Optional Accessories
Support Brace
Standard Mounting Style
Standard Mounting hangs from the ceiling by a downrod (included).
Support Brace
Ceiling Outlet Box
Angled Mounting Style
Ceiling Outlet Box
12
Understanding Mounting and Installer’s Choice®
Hunter’s patented 3-position mounting system provides you maximum installation flexibility and ease. You can install your Hunter fan in one of three ways, depending on ceiling height and your preference: Low Profile, Standard, or Angled mounting. e steps in this manual include instructions for all three Installer’s Choice mounting methods.
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted or remote speed control. To install and use the accessories, follow the instructions included with each product. For quiet and optimum performance of your Hunter fan, use only Hunter speed controls.
For ceilings higher than 8 feet, you can purchase Hunter extension downrods. All Hunter fans use sturdy 3/4” diameter pipe to assure stability and wobble-free performance.
8
Low Profile Mounting Style
Support Brace
Ceiling Outlet Box
CAUTION: To
reduce the risk of personal injury, attach the fan directly to the support structure of the building according to these instructions, and use only the hardware supplied.
Angled Mounting recommended for a vaulted or angled ceiling
42693-01 • 05/14/10 • Hunter Fan Company
Low Profile Mounting fits close to the ceiling, recommended for ceilings less than 8 feet high
5
1 • Getting Ready
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to the included Parts Guide. Check for any shipping damage to the motor or fan blades. If any parts are missing or damaged, contact your Hunter dealer or call Hunter Technical Support Department at 888-830-1326 (In Canada, call 1-866-268-1936).
Installing Multiple Fans?
If you are installing more than one fan, keep the fan blades and blade irons (if applicable) in sets, as they were shipped.
Preparing the Fan Site
Before you begin installing the fan, follow all the instructions in “Preparing the Fan Site.” Proper ceiling fan location and attachment to the building structure are essential for safety, reliable operation, maximum efficiency, and energy savings.
6
42693-01 • 05/14/10 • Hunter Fan Company
Loading...
+ 13 hidden pages