Human Touch IU10067 Specifications

Page 1
1.0 Reference and Address
Listing Constructional Data Report (CDR)
Report Number
Standard(s)
Address Address
Country Country Contact Contact
Phone Phone
FAX FAX
Email Email
181001126SHA-001
Motor-Operated Massage And Exercise Machines [UL 1647:2015 Ed.6+R:28Jan2020]
Motor-Operated Appliances (Household and Commercial) (R2019) [CSA C22.2#68:2018 Ed.8+U1]
Shanghai Rongtai Health Technology Corporation Limited
No. 1226, Zhufeng Road, Qingpu, Shanghai
China China Mr. Xu Haiqing Mr. Xu Haiqing 86 13636676285
Original Issued: 5-Nov-2018 Revised: 7-Jun-2021
Shanghai Rongtai Health Technology Corporation Limited
No. 1226, Zhufeng Road, Qingpu, Shanghai
86 13636676285
Page 1 of 43
Page 2
Report No. 181001126SHA-001
2.0 Product Description
Page 2 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Product Brand name
Description
Models
Model Similarity
Ratings
Other Ratings
Massage chair NA The product covered in the report is single phase, stationary, detachable cord-
connected massage chair intended for household indoor use only RT5861
NA
110-120V~, 60Hz, 1.2A
NA
ED 16.3.15 (5-Jun-2021) Mandatory
Page 3
Report No. 181001126SHA-001
Photo 1 - Front view
Photo 2 - Back view
3.0 Product Photographs
Page 3 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
14
1
2
ED 16.3.15 (5-Jun-2021) Mandatory
Page 4
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 3 - Side view
Photo 4 - Side view
Page 4 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
36
ED 16.3.15 (5-Jun-2021) Mandatory
Page 5
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 5 - Bottom view
Photo 6 -Main enclosure
Page 5 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
13
ED 16.3.15 (5-Jun-2021) Mandatory
Page 6
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 7 - Cord connector and appliance inlet
Photo 8 - Internal view
Page 6 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
4
7
3
ED 16.3.15 (5-Jun-2021) Mandatory
Page 7
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 9 - Internal view
Photo 10 - Internal view
Shanghai Rongtai Health Technology Corporation Limited
Page 7 of 43
Issued: 5-Nov-2018
Revised: 7-Jun-2021
15
16
17
5
8
19
25
18
32
27
26
6
20
ED 16.3.15 (5-Jun-2021) Mandatory
Page 8
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 11 - Power PCB
Photo 12 - Power PCB
Shanghai Rongtai Health Technology Corporation Limited
Page 8 of 43
Issued: 5-Nov-2018
Revised: 7-Jun-2021
9
11
12
10
ED 16.3.15 (5-Jun-2021) Mandatory
Page 9
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 13 - Air pump
Photo 14 - Ring transformer
Page 9 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
33
24
ED 16.3.15 (5-Jun-2021) Mandatory
Page 10
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 15 -Solenoid valve
Photo 16 - Front view after remove foot massage bag
Page 10 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
34
ED 16.3.15 (5-Jun-2021) Mandatory
Page 11
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 17 - Back cushion
Photo 18 - Back cushion
Page 11 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
35
ED 16.3.15 (5-Jun-2021) Mandatory
Page 12
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 20 - Foot rolling motor and Leg up-down motor
Photo 21 - Back massage head
Page 12 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
31
28
ED 16.3.15 (5-Jun-2021) Mandatory
Page 13
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 22 - Reclining motor
Photo 23 - Back motor
Page 13 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
30
29
23
ED 16.3.15 (5-Jun-2021) Mandatory
Page 14
Report No. 181001126SHA-001
3.0 Product Photographs
Photo 24 - Back motor internal view
Photo 25 - Heating wire, thermostat and thermal cut-out
Shanghai Rongtai Health Technology Corporation Limited
Page 14 of 43
Issued: 5-Nov-2018
Revised: 7-Jun-2021
40
39
37
38
ED 16.3.15 (5-Jun-2021) Mandatory
Page 15
Report No. 181001126SHA-001
#
Item
1
Mark(s) of
ELECTRONIC CO
Xiamen Faratronic
4.0 Critical Components
Page 15 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Photo
Name
no.
2 1 Attachment plug
2 2 Power Cord
7 Cord connector cULus125V, 10A, IEC-C133
7 4 Appliance inlet
9
9 6 Main switch
Manufacturer/ trademark
2
CHAU'S ELECTRICAL CO LTD KUN SHAN CHAU'S ELECTRICAL CO LTD CHAU'S ELECTRICAL CO LTD Zhejiang LECI Electronics Co., Ltd SHANGHAI CII ELECTRONICS CO LTD
SUZHOU ZHILE ELECTRONICAL FACTORY
ZHEJIANG LECI ELECTRONICS CO LTD ZHE JIANG BEI ER JIA
Type / model
SP-035
2
means
NEMA Config. 5-15P, rated 10A, 125V~ with 18AWG cord.
conformity
3
cULus
Technical data and securement
Cat.NO.18AWG×3C,rated 300V
SJT
105℃,VW-1 with a minimum
cULus
length 1.83m
SP-024 SP-023R
DB-14 250V~, 10A cURus
RB-1-5
250V~, 6A cURusEMI filter5 CW1B-06A­T(05)
RS601D
125V, 10A cURus PS8A
9 8
Fuse in fuse
77
holder
X-capacitor on filter PCB
LTD XC
Electronics(Shen zhen)Corp.Ltd
Sunny East Enterprise Co. Ltd.
Tenta Electric Industrial Co. Ltd.
DAIN ELECTRONICS CO LTD
Winday Electronic Industrial Co.Ltd
Shantou High­New Technology Development Zone Songtian Enterprise Co.,Ltd
Shenzhen Surong Capacitors Co.,Ltd
5F
GFL
MEX
MPX
MPX
MPX
MPX
250V, 5A cURus
1.0μF 275VAC
cURus
Co.,Ltd
MKP62
ED 16.3.15 (5-Jun-2021) Mandatory
Page 16
Report No. 181001126SHA-001
#
Item
1
Mark(s) of
4.0 Critical Components
PLASTICS CORP
HWI=2.HAI=0, RTI=120, Minimum
Co.,LTD
VW-1
VW-1
18-24 AWG, rated
℃
VW-1
Wire connector on
Page 16 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Photo
Manufacturer/ trademark
2
Type / model
no.
Name
Shanghai Rongtai Health Technology Corporation
EOP-10-5F
11 9
Built-in Class 2 Power Supply
Limited SHANGHAI KETER NEW MATERIALS CO LTD
KT30-2500B
12 10
PTC current limiter on main PCB
VH
CWB GROUP CO LTD
PH SM series
12 11
PCB
YUEQING CHUANGFA ELECTRONICS CO LTD
ZWGBH2.0 ZWG1.25
ZWGBHD3.5­2P
12 12 PCB Various Various
Chi Mei Corporation
PA-765
6 13 Enclosure
2 14
Marking label (not shown)
FORMOSA
Koan Hao Enterprise
Yungsox 1124H
THSMI50 Rated 80°C cURus
Technical data and securement
2
means
Input: 100-240VAC, 50/60Hz, 2A;
AC output:100-240VAC, 50/60Hz,
2A
DC Output: 5VDC, 2A
Ih=2.5A, It=5A Tmoa=85℃
Rated 300V, 105°C cURus
Single layer printed wiring boards,
rated V-0, 130°C
ABS material, rated 5VA, HWI=2,
HAI=0, RTI=80.Minimum 2.5mm
thick
PP material, rated HB,
3.0 mm thick
conformity
3
cETLus
cURus
cURus
cURus
9 15 Various
Internal wire
AWM1015
9 16 Shrinkable tube Various Various
9 17 PVC tube 1 Various Various
10 18 PVC tube 2 Various Various
AWM 1007
WENZHOU ZHUCHENG ELECTRICAL CO LTD
TP25012K-2
TP25032A-3
JIAN HUI METAL
9
Quick connector
19
(metal)
PLASTIC PART FACTORY DE CHANG TERMINALS
J704
DCT-764
FACTORY SHUN SHENG TERMINAL MFG
752-BS
LTD
300/600V.80/105
,
Rated 600V, 125℃,
Rated 300V, 105℃,
VW-1
Rated 600V, 105℃,
Rated 300V. 105℃
cURus
cURus
cURus
cURus
cURus
ED 16.3.15 (5-Jun-2021) Mandatory
Page 17
Report No. 181001126SHA-001
#
Item
1
Mark(s) of
4.0 Critical Components
19V, 1A; Outpu2: 21V, 8A Class A
19V, 1A; Outpu2: 21V, 8A Class A
Hangzhou
Co.,Ltd
ENTERPRISE CO
Page 17 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Photo
Name
no.
10 20 Wire tie
23 23
Splicing wire connector
14 24 Ring transformer
10 25 Kneading motor
10 26 Tapping motor
Manufacturer/ trademark
2
HUA WEI INDUSTRIAL CO LTD
KAI SUH SUH
LTD HEAVY POWER
CO LTD Shanghai Qiman Electronic Technology Co., Ltd
Shanghai Weiten DianZi KeJi You Xian Gong Si
Shanghai Rongtai Health Technology Corporation Limited
SHENZHEN MODO MOTOR CO.,LTD
Type / model
2
means
conformity
3
Technical data and securement
GT-80M Rated 75°C
CV-100
cURus
Rated 85°C CV-160L
CE2 Rated 300V, 90°C cURus
Input: 110V 50/60Hz; Output1: RT-077-1
See 5.0
insulaion system
Input: 110V 50/60Hz; Output1: RT-077-1
See 5.0
insulaion system
63ZY02401
RT3434D024A
Rated 24V DC.3.0A(rated load)
Class A insulaion system
Rated 24V DC.0.8A(rated load)
Class A insulaion system
NR
NR
10 27 Up-down motor
20 28 Foot rolling motor
23 29 Back motor
Fusheng Electric
Jiashan Ou Yuan Motor Co.Ltd
Shanghai Rongtai Health Technology Corporation Limited CHANGZHOU KAIDI ELECTRONICAL CO.,LTD Shanghai Rongtai Health Technology Corporation Limited Shanghai Rongtai Health Technology Corporation Limited
ZYT61-A
ZYT-50SF-20­19AW
KDFSJ
63ZY24-80
63ZY24-220-HS
Rated 24V DC.1.1A(rated load)
Class A insulaion system
Rated 24V DC.20W(rated load)
Class A insulaion system
Rated 24V DC.55W(rated load)
Class A insulaion system
Rated 24V DC.55W(rated load)
Class A insulaion system
Rated 24V DC.55W(rated load)
Class A insulaion system
NR
NR
NR
NR
NR
ED 16.3.15 (5-Jun-2021) Mandatory
Page 18
Report No. 181001126SHA-001
#
Item
1
Mark(s) of
4.0 Critical Components
Page 18 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Photo
no.
22 30
20 31
10
32
3313
Name
Reclining motor
Leg up-down motor
Thermal protector in motor
Air pump
Manufacturer/ trademark
2
CHANGZHOU KAIDI ELECTRONICAL CO.,LTD
Shanghai Rongtai Health Technology Corporation Limited
Shanghai Rongtai Health Technology Corporation Limited
SHENZHEN MODO MOTOR CO.,LTD
CHANGZHOU AINUO ELECTRONICS TECHNICAL CO LTD
CHANGZHOU AINUO ELECTRONICS TECHNICAL CO LTD
VICTOR ELECTRIC CO LTD
Zhejiang pearl feng electronics technology Co., LTD
FuAn YiLong Electric Appliance Co.,Ltd.
Type / model
2
KDFSJ
63ZY24-80
63ZY24-220-HS
RT3434D024A
KW-***
KW-E
V7AM020A5
YX250A
YL-250A
Technical data and securement
means
Rated 24V DC.55W(rated load)
Class A insulaion system
Rated 24V DC.55W(rated load)
Class A insulaion system
Rated 24V DC.55W(rated load)
Class A insulaion system
Rated 24V DC.0.8A(rated load)
Class A insulaion system
250V~, 80°C for up-down、
Kneading、 Foot rolling
motor(manufacture by Shanghai
Rongtai)
250V~, 65°C for Tapping motor
and Leg up-down motor
250V~, 65°C for foot rolling
motor(manufacture by Ou Yuan)
AC24V, 60Hz, 20W, Class A
insulaion system
conformity
3
NR
NR
NR
NR
cURus
NR
15 34 Solenoid valve NR
Ningbo Shengqiang Chenyi Electronic Technology Co., Ltd
Ningbo FengHua ShengXiong Mechanical and Electrical
CY040-4H
CY040-2RB
CY040-2LR SX040-4H
SX040-2RB SX040-2LR
Rated 24V DC, Class A insulation
system
ED 16.3.15 (5-Jun-2021) Mandatory
Page 19
Report No. 181001126SHA-001
#
Item
1
Mark(s) of
4.0 Critical Components
Rated 250V~ 6A, 75°C in backrest
℃
3) Indicates specific marks to be verified, which assures the agreed level of surveillance for the component. "NR"
Suzhou Ai Xinrong
Page 19 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Photo
Name
no.
18 35 Foam
interconnection
364
cord
25 38 Thermal cut-out
25 39 Thermostat
Manufacturer/ trademark
2
FOAMEX INNOVATIONS OPERATING CO, DBA FXI FOAMEX INNOVATIONS
Various
New Material Technology Co., Ltd.,
Changzhou Ainuo Electronics Technical Co.,Ltd
Changzhou Ainuo Electronics Technical Co.,Ltd
Type / model
2
means
conformity
3
Technical data and securement
CMHR 45-35 HF-1 cURus
AWM2464
18-24 AWG, rated 300V, 80°C
cURus
AWM2468
AXR.12.37-12
13W, 24VDC, Resistance type
NRheating element3725
AXR.12.37-13
17AM75
cushion
cURus
100000 Cycles.
250V~, 6A, 65 17AM65
in backrest cushion for heating
cURus
element. 100000 Cycles.
Fuzetec
FRX160-60F
PTC Protector4024 cURus
Technology Co., Ltd.
FRX250-60F
60VDC,3.2A for Leg reclining
motor and Back motor.
60VDC,5A for Leg reclining motor
and Back motor.
NOTES:
1) Not all item numbers are indicated (called out) in the photos, as their location is obvious.
2) “Various“ means any type, from any manufacturer that complies with the "Technical data and securement means" and meets the "Mark(s) of conformity" can be used.
- indicates Unlisted and only visual examination is necessary. "See 5.0" indicates Unlisted components or assemblies to be evaluated periodically refer to section 5.0 for details.
ED 16.3.15 (5-Jun-2021) Mandatory
Page 20
Report No. 181001126SHA-001
ZHANGZHOU
5.0 Critical Unlisted CEC Components
Technology Co., Ltd
Page 20 of 43
Shanghai Rongtai Health Technology Corporation Limited
INSULATED COIL
Photo # Item no.
Name Manufacturer/Trademark Type / model
Issued: 5-Nov-2018
Revised: 7-Jun-2021
14 24
Electrical Rating:
Ring transformer
Input: 110V, 50/60Hz; Output1: 19.0V, 1.0A; Output2: 21.0V, 8.0A
Component Standard used: UL 1647
MATERIALS LIST
Component
Manufacturer Type/model NINGBO JINTIAN NEW MATERIAL CO LTD
Primary windings
HOLDING GROUP CO LTD
NINGBO JINTIAN NEW MATERIAL CO LTD
secondary windings
XIANDENG HOLDING GROUP CO LTD
ZHANGZHOU
Thermal link 1
AUPO ELECTRONICS CO LTD
PEW QZ
PEW
PEW QZ
PEW
A4
Shanghai Qiman Electronic
Dimensions/thickness/assembly information
Polyester-imide coated magnet wire, rated 155°CXIANDENG
Polyester-imide coated magnet wire, rated 155°C
Rated 250V, 5A, 130°C
RT-077-1
Insulation class
A
Thermal link 2
AUPO ELECTRONICS
BF133
Rated 250V, 10A, 133°C
CO LTD SHANGHAI
XINHUI WIRE
Primary Lead wire AWM 1672 18AWG, rated 300V, 105°C
CABLE CO LTD Various
KUNSHAN XINGHONGMEN G ELECTRONIC CO LTD
Secondary Lead wire AWM 3321
DONG GUAN
18AWG, rated 600VAC, 750VDC, 150°C
SHENG PAI ELECTRIC WIRE CABLE CO LTD
Various
WC11G WC22
FWS
Polyethylene terephthalate film tape, rated 105°C
Polyethylene terephthalate film tape, rated 130°C
Insulation tape
DUPONT TEIJIN FILMS U S L P
JINGJIANG FUWEI ADHESIVE PRODUCT CO LTD
ED 16.3.15 (5-Jun-2021) Mandatory
Page 21
Report No. 181001126SHA-001
5.0 Critical Unlisted CEC Components
Wire Size
(AWG or mm
)
Page 21 of 43
Shanghai Rongtai Health Technology Corporation Limited
SHANGHAI
Heat-shrinkable tube
SHENDIAN INDUSTRY & TRADE LTD CO
SRG-514
DONGGUAN QUANTAI ELECTRONICS
T-2
CO LTD
WINDING(S) RESISTANCE
Winding Designation
2
Wire Type Turns Volts Amps
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Rated 600V, 125°C, VW-1
DC resistance
(Ω) +/- 10%:
Primary winding / PEW, QZ 1.948 Secondary winding 1 / PEW, QZ 0.736 Secondary winding 2
/
/ 110 / / 19 1.0A / 21 8A
0.112PEW, QZ
VERIFICATION PROCESS
Frequency:
Annual 1
Test Site:
CEC
Number of samples to test:
Test Name Test Parameters
Winding resistance See resistance per winding above.
Apply voltage Between Test Voltage Test Time
Dielectric Strength
Primary to secondary 2500V 60s
Secondary to secondary 1240V 60s
INSULATED COIL
Photo # Item no.
Name Manufacturer/Trademark Type / model
Shanghai waiten electron
14 24
Ring transformer
science and technology
RT-077-1
co.,Ltd
Electrical Rating:
Input: 110V, 50/60Hz; Output1: 19V, 1.0A; Output2: 21V, 8A
Insulation class
A
Component Standard used: UL 1647 Component Manufacturer
NINGBO JINTIAN
Primary windings
NEW MATERIAL CO LTD
NINGBO JINTIAN
secondary windings
NEW MATERIAL CO LTD
XIAMEN SET
Thermal link 1
ELECTRONICS CO LTD
ZHANGZHOU
Thermal link 2
AUPO ELECTRONICS CO LTD
Type/model Dimensions/thickness/assembly information
QZ-2
QZ-2
Polyester-imide coated magnet wire, rated 155°C
Polyester-imide coated magnet wire, rated 155°C
Y4 Rated 250V, 5A, 130°C
BF133 Rated 250V, 10A, 133°C
ED 16.3.15 (5-Jun-2021) Mandatory
Page 22
Report No. 181001126SHA-001
5.0 Critical Unlisted CEC Components
Page 22 of 43
Shanghai Rongtai Health Technology Corporation Limited
JIANGSU ELECO ELECTRONICS
Primary Lead wire
TECHNOLOGY CO LTD
AWM 1672 18AWG, rated 300V, 105°C
Various SHENZHEN QI
Secondary Lead wire
FU RUI
AWM 3321 18AWG, rated 600VAC, 750VDC, 150°C
Various
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Insulation tape
JINGJIANG YA HUA
CT286F
Polyethylene terephthalate film tape, rated 130°C
SHENZHEN
Heat-shrinkable tube
WOLIDA TRADING CO
RSFR-H
Polyethylene terephthalate film tape, rated 125°C
LTD
WINDING(S) RESISTANCE
Winding Designation
Primary winding / Secondary winding 1 / QZ 0.638 Secondary winding 2 0.120
Wire Size
(AWG or mm2)
/ QZ
Wire Type Turns Volts Amps
QZ 1.840
/ 110 /
DC resistance
(Ω) +/- 10%:
/ 19 1.0A / 21 8A
VERIFICATION PROCESS
Frequency:
Annual 1
Test Site:
Test Name
CEC
Test Parameters
Number of samples to test:
Winding resistance See resistance per winding above.
Test Time
Dielectric Strength
Apply voltage Between Test Voltage
Primary to secondary 2500V 60s
Secondary to secondary 1240V 60s
ED 16.3.15 (5-Jun-2021) Mandatory
Page 23
Report No. 181001126SHA-001
- Components such as switches, fuseholders, connectors, wiring terminals and display
- All exposed dead-metal parts and all dead-metal parts within the enclosure that are exposed are
abrasion or damage by plastic bushings or grommets. All wiring is minimum 24 AWG, with a minimum rating
6.0 Critical Features
Page 23 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Recognized Component - A component part, which has been previously evaluated by an accredited certification body with restrictions and must be evaluated as part of the basic product considering the restrictions as specified by the Conditions of Acceptability.
Listed Component - A component part, which has been previously Listed or Certified by an accredited Certification Organization with no restrictions and is used in the intended application within its ratings.
Unlisted Component - A part that has not been previously evaluated to the appropriate designated component standard. It may also be a Listed or Recognized component that is being used outside of its evaluated Listing or component recognition.
Critical Features/Components - An essential part, material, subassembly, system, software, or accessory of a product that has a direct bearing on the product’s conformance to applicable requirements of the product standard. Construction Details - For specific construction details, reference should be made to the photographs and descriptions. All dimensions are approximate unless specified as exact or within a tolerance. In addition to the specific construction details described in this Report, the following general requirements also apply.
1. Spacing - In primary circuits, __3.0_ mm minimum spacing are maintained through air and over surfaces of insulating material between current-carrying parts of opposite polarity and __3.2_ mm minimum between such current-carrying parts and dead-metal parts or low voltage isolated circuits.
2. Mechanical Assembly lamps are mounted and prevented from shifting or rotating by the use of lockwashers, starwashers, or other mounting format that prevents turning of the component.
3. Corrosion Protection - All ferrous metal parts are protected against corrosion by painting, plating or the equivalent.
4. Accessibility of Live Parts - All uninsulated live parts in primary circuitry are housed within a non-metallic enclosure constructed with no openings other than those specifically described in Sections 4 and 5.
5. Grounding connected to the grounding lead of the power supply cord
6. Polarized Connection - This product is provided with a polarized power supply connection. All single pole switches and fuses are connected only to the ungrounded supply circuit conductor.
7. Internal Wiring - Internal wiring is routed away from sharp or moving parts. Internal wiring leads terminating in soldered connections are made mechanically secure prior to soldering. Recognized Component separable (quick disconnect) connectors of the positive detent type, closed loop connectors, or other types specifically described in the text of this report are also acceptable as internal wiring terminals. At points where internal wiring passes through metal walls or partitions, the wiring insulation is protected against
of 300V, 80°C.
8. Markings - The product is marked on as labeling system as described in item no. _14_ of Section 4.0 as follows: Applicant's name, brand name, model number, date of manufacturer, electrical ratings (volts, current & frequency ).
9. Cautionary Markings - Refer to Illustration No(s). 15 for details.
10. Installation, Operating and Safety Instructions - Instructions for installation and use of this product are provided by the manufacturer. Refer to Illustration No(s). 1-12 for details.
ED 16.3.15 (5-Jun-2021) Mandatory
Page 24
Report No. 181001126SHA-001
Illustration 1 - Manual
7.0 Illustrations
Page 24 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 25
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 2 - Manual
Page 25 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 26
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 3 - Manual
Page 26 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 27
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 4 - Manual
Page 27 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 28
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 5 - Manual
Page 28 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 29
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 6 - Manual
Page 29 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 30
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 7 - Manual
Page 30 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 31
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 8 - Manual
Page 31 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 32
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 9 - Manual
Page 32 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 33
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 10 - Manual
Page 33 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 34
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 11 - Manual
Page 34 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 35
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 12 - Manual
Page 35 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 36
Report No. 181001126SHA-001
7.0 Illustrations
Illustration 15 - Cautionary Marking label (near the position of fuse replacement)
Page 36 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
ED 16.3.15 (5-Jun-2021) Mandatory
Page 37
Report No. 181001126SHA-001
0181008-102-003
8.0 Test Summary
Page 37 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Evaluation Period Project No. 181001126SHA
8-Oct-2018 to 02-Nov-2018 Sample Rec. Date 8-Oct-2018 Condition Prototype Sample ID. Test Location Test Procedure
Building No. 86, 1198 Qinzhou Road (North), Shanghai 200233, P. R. China
Testing Lab Determination of the result includes consideration of measurement uncertainty from the test equipment and
methods. The product was tested as indicated below with results in conformance to the relevant test criteria. The following tests were performed:
Test Description Stability Leakage-Current Test Leakage Current Following Humidity Conditioning Starting-Current Test Input Test Temperature Test Surface Temperatures Dielectric Voltage-Withstand Test Switch and Control Test Operational Test Abnormal-Operation Test Polymeric Enclosure Tests Polymeric Materials Used as Structural Support
Shiatsu-Type Massager Entrapment Test General Purpose Transformers
UL 1647:2015 Ed.6+R:26Jul2018
38 45 46 47 48 49 50 52 58 63 64 66 67
70 75
Test Description Starting
CSA C22.2#68:2009 Ed.7+U1;U2;U3
6.3 Rating 6.4 Temperature (Normal) Dielectric Strength Temperature (Abnormal) Overload and Endurance (Switches and Controls) Leakage Current Stability Physical Abuse Moisture-Absorption Resistance of Insulation
6.5
6.6
6.7
6.8
6.9
6.10
6.11
6.18 Motorized Chairs, Beds, and Exercise Appliances 6.20 Oven Conditioning (Nonmetallic Enclosures)
6.21 Test Description UL 2111:1997 Ed.1 +R:27Jan2006
Locked-Rotor Temperature Test 14 Dielectric Voltage-Withstand Test 15 Locked-Rotor Endurance Test 16
Test Description CSA C22.2#77 Issued: 2014/08/01 Locked-Rotor Temperature 6.4 Dielectric Strength 6.5 Endurance 6.6
ED 16.3.15 (5-Jun-2021) Mandatory
Page 38
Report No. 181001126SHA-001
8.0 Test Summary
0210602-023-008
Completed by:
Reviewed by:
Signature:
Signature:
Page 38 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Evaluation Period Project No. 210600657SHA
2-Jun-2021 to 07-Jun-2021 Sample Rec. Date 2-Jun-2021 Condition Prototype Sample ID. Test Location Test Procedure
Building No. 86, 1198 Qinzhou Road (North), Shanghai 200233, P. R. China
Testing Lab Due to the previous testing performed under Intertek Report 181001126SHA-001 no additional testing was
necessary. The following tests were performed:
Test Description UL 1647:2015 Ed.6+R:28Jan2020 Test Description CSA C22.2#68:2018 Ed.8+U1
8.1 Signatures
A representative sample of the product covered by this report has been evaluated and found to comply with the applicable requirements of the standards indicated in Section 1.0.
Robin Shi
Title: Title:
Project Engineer
Curry Wang
Technical Supervisor
ED 16.3.15 (5-Jun-2021) Mandatory
Page 39
Report No. 181001126SHA-001
Brand Name
human touch
9.0 Correlation Page For Multiple Listings
Page 39 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
The following products, which are identical to those identified in this report except for model number and Listee name, are authorized to bear the ETL label under provisions of the Intertek Multiple Listing Program.
BASIC LISTEE
Address
Country Product
MULTIPLE LISTEE 1
Address
Country
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 1 MODELS
Human Touch® Sana
Human Touch® Quies
MULTIPLE LISTEE 2
Address
Country
Brand Name
Shanghai Rongtai Health Technology Corporation Limited No. 1226, Zhufeng Road, Qingpu, Shanghai China
Massage chair
Human Touch, LLC 4600E. Conant St., Long Beach, CA 90808 U.S.A
Shanghai Rongtai Health Technology Corporation Limited
No. 1226, Zhufeng Road, Qingpu, Shanghai China
BASIC LISTEE MODELS
RT5861 RT5861
None
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 2 MODELS
MULTIPLE LISTEE 3
Address
Country
Brand Name
ASSOCIATED
MANUFACTURER
Address
Country
MULTIPLE LISTEE 3 MODELS
BASIC LISTEE MODELS
None
BASIC LISTEE MODELS
ED 16.3.15 (5-Jun-2021) Mandatory
Page 40
Report No. 181001126SHA-001
10.0 General Information
Page 40 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
The Applicant and Manufacturer have agreed to produce, test and label ETL Listed products in accordance with the requirements of this Report. The Manufacturer has also agreed to notify Intertek and to request authorization prior to using alternate parts, components or materials.
COMPONENTS Components used shall be those itemized in this Intertek report covering the product, including any amendments and/or revisions.
LISTING MARK The ETL Listing mark applied to the products shall either be separable in form, such as labels purchased from Intertek, or on a product nameplate or other media only as specifically authorized by Intertek. Use of the mark is subject to the control of Intertek.
The mark must include the following four items:
1) applicable country identifiers "US" and/or "C" or "US", "C" and "EU"
2) the word "Listed" or "Classified" or "Recognized Component" (whichever is appropriate)
3) a control number issued by Intertek
4) a product descriptor that identifies the standards used for certification. Example:
For US standards, the words, “Conforms to” shall appear with the standard number along with the word, “Standard” or “Std.” Example: “Conforms to ANSI/UL Std. XX.”
For Canadian standards, the words “Certified to CAN/CSA Standard CXX No. XX.” shall be used, or abbreviated, “Cert. to CAN/CSA Std. CXX No. XX.”
Can be used together when both standards are used.
If all standards on the ATM have the same standard title, the shared title or its abbreviation may be used in place of the examples above. Example: "Medical Electrical Equipment" or "MEE"; "Information Technology Equipment" or "ITE"; "Audio/Video Information And Communication Technology Equipment" or "A/V ICTE".
Note: A facsimile must be submitted to Intertek, Attn: Follow-up Services for approval prior to use. The facsimile need not have a control number. A control number will be issued after signed Certification Agreements have been received by the Follow-up Services office, approval of the facsimile of your
proposed Listing Mark, satisfactory completion of the Listing Report, and scheduling of a factory
MANUFACTURING AND PRODUCTION TESTS Manufacturing and Production Tests shall be performed as required in this Report.
FOLLOW‑UP SERVICE Periodic unannounced audits of the manufacturing facility (and any locations authorized to apply the mark) shall be scheduled by Intertek. An audit report shall be issued after each visit. Special attention will be given to the following:
1. Conformance of the manufactured product to the descriptions in this Report.
2. Conformance of the use of the ETL mark with the requirements of this Report and the Certification Agreement.
3. Manufacturing changes.
4. Performance of specified Manufacturing and Production Tests. In the event that the Intertek representative identifies non-conformance(s) to any provision of this Report, the
Applicant shall take one or more of the following actions:
1. Correct the non-conformance.
2. Remove the ETL Mark from non-conforming product.
3. Contact the issuing product safety evaluation center for instructions.
ED 16.3.15 (5-Jun-2021) Mandatory
Page 41
Report No. 181001126SHA-001
10.1 Evaluation of Unlisted Components
Page 41 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
Because Unlisted Components are uncontrolled, and they do not fall under a third party follow up program, Intertek may require these components to be tested and/or evaluated at least once annually, more often for certain components, as part of the independent certification process. The Unlisted Components in Section 5.0 require testing and/or evaluation as indicated.
The Applicant will be notified, in writing, via the applicable contact methods, as defined in Section 1.0, when these components must be selected and sent to Component Evaluation Center (CEC) for re­evaluation.
Due to particular testing requirements, some components may be requested to be shipped to specific labs. Thus, specific shipment destination(s) for each sample will be provided in the written notification.
Managing CEC Location:
Intertek Testing Services Shanghai Limited
ETL Component Evaluation Center
Building No. 86, 1198 Qinzhou Road (North)
Shanghai 200233, China
Attn: Ms. Angela Han
Sample Disposition: Due to the destructive nature of the testing, all samples will be
discarded at the conclusion of testing unless, the manufacturer specifically requests the
return of the samples. The request for return must accompany the initial component
shipment.
ED 16.3.15 (5-Jun-2021) Mandatory
Page 42
Report No. 181001126SHA-001
Product
Test Voltage
Test Time
11.0 Manufacturing and Production Tests
Dielectric Voltage Withstand Test
switches, contractors, relays, etc., should be closed so that all primary circuits are energized by the test potential.
Page 42 of 43
Shanghai Rongtai Health Technology Corporation Limited
Issued: 5-Nov-2018
Revised: 7-Jun-2021
The manufacturer agrees to conduct the following Manufacturing and Production Tests as specified:
Required Tests
Grounding Continuity Test
11.1 Dielectric Voltage Withstand Test
Method
One hundred percent of production of the products covered by this Report shall be subjected to a routine production line dielectric withstand test.
The test shall be conducted on products, which are fully assembled. Prior to applying the test potential, all
If all primary circuits cannot be tested at one time, then separate applications of the test potential shall be made.
The test voltage specified below shall be applied between primary circuits and accessible dead-metal parts. The test voltage may be gradually increased to the specified value but must be maintained at the specified value for one second or one minute as required.
Test Equipment
The test equipment shall incorporate a transformer with an essentially sinusoidal output, a means to indicate the applied test potential, and an audible and/or visual indicator of dielectric breakdown.
The test equipment shall incorporate a voltmeter in the output circuit to indicate directly the applied test potential if the rated output of the test equipment is less than 500VA.
If the rated output of the test equipment is 500VA or more, the applied test potential may be indicated by either: 1 - a voltmeter in the primary circuit; 2 - a selector switch marked to indicate the test potential; or 3 - a marking in a readily visible location to indicate the test potential for test equipment having a single test potential output. In cases 2 and 3, the test equipment shall include a lamp or other visual means to indicate that the test potential is present at the test equipment output. All test equipment shall be maintained in current calibration.
Products Requiring Dielectric Voltage Withstand Test:
All products covered by this Report. 1240V 60 s
or
1488V 1 s
11.2 Grounding Continuity Test
Method
Each product listed below shall be subjected to a test to determine that there is continuity between accessible dead-metal parts of the product and the grounding pin or blade of the attachment plug.
If all accessible dead metal is connected, only a single test need be performed. A visual or audible device (ohmmeter, buzzer, etc.) may be used to indicate grounding continuity.
Products Requiring Grounding Continuity Test:
All products covered by this Report.
ED 16.3.15 (5-Jun-2021) Mandatory
Page 43
Report No. 181001126SHA-001
Delete manufacturers and models of shrinkable tube and use
12.0 Revision Summary
Page 43 of 43
Shanghai Rongtai Health Technology Corporation Limited
The following changes are in compliance with the declaration of Section 8.1: Date/ Project Handler/ Proj # Site ID Reviewer
Section Item Description of Change
Update standard from: Motor-Operated Massage And Exercise Machines [UL 1647:2015 Ed.6+R:26Jul2018] Motor-Operated Appliances (Household And Commercial)
7-Jun-2021 Robin Shi -
[CSA C22.2#68:2009 Ed.7+U1;U2;U3] to Motor-Operated Massage And Exercise Machines [UL 1647:2015 Ed.6+R:28Jan2020]
1.0
Motor-Operated Appliances (Household and Commercial) (R2019) [CSA C22.2#68:2018 Ed.8+U1]
Change contact person from "Mr. Wang Xin" to "Mr. Xu Haiqing" Change phone number from "86-21-31190888-8021" to "86
210600657SHA
Curry Wang -
13636676285" Delete fax number and used "-" instead Change email from "[email protected]" to "[email protected]"
Issued: 5-Nov-2018
Revised: 7-Jun-2021
3.0
19 Delete photo 19 25 Add photo 25
Correct technical data of cord connector from "250V, 10A,
3
IEC-C13" to "125V, 10A, IEC-C13"
16
"Various" instead. Delete manufacturers and models of PVC tube 1 and use
17
"Various" instead. Delete manufacturers and models of PVC tube 2 and use
18
"Various" instead. 21 Delete item 21 22 Delete item 22
Change manufacturer from "Wenzhou Yuanxin Mechanical
4.0
33
and Electrical Factory" to "Zhejiang pearl feng electronics
technology Co., LTD".
Change manufacturers from "Fenghua Chenyi Pneumatic
Equipment Factory and FengHua Xi kou ShuangXiong 34
Machinery accessories Factory" to " Ningbo Shengqiang
Chenyi Electronic Technology Co., Ltd and Ningbo FengHua
ShengXiong Mechanical and Electrical Technology Co., Ltd." 37 Add item 37 for heating element
38 Add item 38 for Thermal cut-out 39 Add item 39 for Thermostat 40 Add item 40 for PTC Protector
7.0
13 Delete marking label 14 Delete Marking label for multiple listee model
8.0 - Re-signed
9.0 1
Add model "Human Touch®Quies" in multiple listee 1
ED 16.3.15 (5-Jun-2021) Mandatory
Loading...