Hulk HP05V080Y1 Operating Manual

5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor –HP05V080Y1 7/18/2011
HP05V080Y1
HULK COMPRESSOR
Operating Manual
1
5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor –HP05V080Y1 7/18/2011
Breathable Air Warning
This compressor/pump is NOT equipped and should NOT be used “as is” to supply breathing quality air. For any application of air for human consumption, you must fit the air compressor/pump with suitable in-line safety and alarm equipment. This additional equipment is necessary to properly filter and purify the air to meet minimal specifications for Grade D breathing as described in Compressed Gas Association Commodity Specification G 7.1 – 1966, OSHA 29 CFR 1910. 134, and/or Canadian Standards Associations (CSA)
DISCLAIMER OF WARRANTIES
In the event the compressor is used for the purpose of breathing air application and proper in-line safety and alarm equipment is not simultaneously used, existing warranties are void, and EMAX Air Force Technology disclaims any liability whatsoever for any loss, personal injury or damage.
DANGER!
CALIFORNIA PROPOSITION 65
This product or its power cord may contain chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.
READ INSTRUCTION MANUAL BEFORE OPERATING RISK OF FIRE OR EXPLOSION – DO NOT SPRAY
COMBUSTIBLE/FLAMMABLE LIQUID IN A CONFINED AREA. SPRAY AREA MUST BE WELL VENTILATED. DO NOT SMOKE WHILE SPRAYING OR SPRAY WHERE SPARK OR FLAME IS PRESENT. ARCING PARTS – KEEP COMPRESSOR AT LEAST 20 FEET AWAY FROM SPRAYING AREA AND ALL EXPLOSIVE VAPORS.
RISK OF INJURY – DO NOT DIRECT AIR STREAM AT
BODY. USE EYE PROTECTION. COMPRESSOR STARTS AUTOMATICALLY. MOVING PARTS. DO NOT TOUCH. KEEP GUARDS IN PLACE. COMPRESSOR DOES NOT SUPPLY BREATHABLE AIR.
RISK OF BURSTING – DO NOT ADJUST REGULATOR
TO RESULT IN OUTPUT PRESSURE GREATER THAN MARKED MAXIMUM PRESSURE OF ATTACHMENT. IF A REGULATOR HAS NOT BEEN INSTALLED -
USE ONLY ATTACHMENT RATED AT 200 PSI OR HIGHER. DO NOT WELD ON OR REPAIR TANK – REPLACE. DO NOT OPERATE WITHOUT PROPER ASME SAFETY VALVE IN PLACE.
RISK OF ELECTRICAL SHOCK – HAZARDOUS VOLTAGE:
DISCONNECT FROM POWER SOURCE BEFORE SERVICING. COMPRESSOR MUST BE GROUNDED. DO NOT USE GROUNDING ADAPTORS. DO NOT EXPOSE TO RAIN. STORE INDOORS.
IF CONNECTED TO A CIRCUIT PROTECTED BY FUSES, USE TIME-DELAY FUSE MARKED “D”
COMPLIES WITH CCR462 (L)(2).
DO NOT USE BELOW GARAGE FLOOR OR GRADE LEVEL
DRAIN TANK EVERYDAY TO PREVENT CORROSION AND POSSIBLE INJURY DUE TO TANK DAMAGE
Introduction
2
5HP 80 gallon 1 Stage Single Phase 3 Cylinder Air Compressor –HP05V080Y1 7/18/2011
In order to receive maximum performance and long life from your compressor, the following instructions should be read carefully and all points regarding installation and operation of the unit should be noted and observed. Carefully reading this manual before connecting anything to the motor or compressor is necessary for optimum trouble-free operation.
Inspection
Check for possible damage from transit and test the pulley by turning it freely with your hands.
Report any damage to the delivery carrier immediately.
Location
Select a clean, dry, and well-lit location. In cold climates, the compressor should be installed in a heated building. Insulate cold water or other low temperature pipes that pass overhead to avoid possible collection and dripping of condensate onto the compressor and motor that could cause rust and/or motor shorting. Do not install the compressor in a boiler room, paint spray room, or area where sandblasting occurs. If acid or dust is in the air where the compressor is operating, the compressor intake should be piped to the outside. This intake pipe should be increased one pipe size for every twenty (20) feet of run and the intake filter should be installed at the end of the pipes with a hood to protect them from the elements. Special size filters are required for pipe away.
If the compressor has to be located where the motor will be exposed to appreciable quantities of water, oil, dirt, acid, or alkaline fumes, the motor must be of special construction to avoid rapid deterioration; i.e. TEFC
Unless the base is exactly level, shims will probably be required. Any space between base and foot should be shimmed rather than drawing the foot down thus placing strain on the unit. When unit is properly shimmed, vibration will be at a minimum.
Allow sufficient space around the compressor so that it is accessible from all sides for maintenance. Mount the unit with the pulley towards the wall at least 18 inches between pulley & wall.
POWER SUPPLY AND WIRING
Installation should be executed by a licensed electrician All electrical connections must be tightened before starting. This includes
connections at the motor junction as well as the Condor Switch or Magnetic starter. This shall include all factory connections. Repeat: Check all electrical connections before startup.
Wiring should be installed by a licensed electrician who is familiar with requirements of the National Board of Fire Underwriters and of the local inspectors is recommended. Consult your local electrical contractor regarding electric codes and recommended wire sizes.
Single Phase Motors:
3