We are pleased you chose
FEEDBACK circuitry is the ideal medium for
is equally suitable for
the
CF 200
power
amplifier. Its innovative CURRENT
the
modern guitar rack. The CF 200
PA, monitor, and keyboard applications.
PLEASE READ THE FOLLOWING GUIDELINES PRIOR TO OPERATING THE CF 200:
l The European model’s voltage can be adjusted from 220 V to 240 V.
l To avoid overheating, ensure sufficient air circulation is available both at the
sides and to the rear of the CF 200.
l Do not install any units sensitive to heat, for instance effects processors, directly
above the CF 200.
l Never expose the CF 200 to climatic extremes and ensure the amp is always
protected
l To protect your speakers, always switch the CF 200’5 power on last.
l Service and repair work should be left to an authorized repair shop. Before
from moisture.
opening the housing, always ensure the mains power cable is unplugged!
FRONT PANEL CONTROL FEATURES
(
1 ) The VOLUME LEFT and VOLUME RIGHT knobs regulate input sensitivity and
subsequently the power output. In the BRIDGE MODE, only the right control is
activated.
The green -20
correctly adjusted. The red CLIP LED
db LED ( 2
)
indicates the signal level at the respective input is
(
3 ) denotes the signal level is too high, and
the CF 200 is clipping. Adjust the appropriate VOLUME knob so that the red LED
illuminates at impulse peaks only.
(
4 ) GUITAR/PA
The GUITAR/PA switch activates the CURRENT FEEDBACK circuitry (GUITAR mode
=
on, PA = off). The CURRENT FEEDBACK circuitry elicits an amp, producing the
type of signal most desirable for guitar amplification.
( 5
)
MAINS: The MAINS power switch illuminates when engaged.
page 7
,,
,:&.
1 ,, . ..oL1 .
meas
(11(2)(3)
,:&;,
l
..vn
I”
a,
=y-,,,
“CA,,.”
(4)
0
_~__ ___
CF
CLm”rmPTtm.CI
200
mwmw
-0
al
_~~
REAR PANEL FEATURES AND FUNCTIONS
(
0 ) Prior to plugging the factory-included EUROMAINS CABLE in the AC receptacle
off the
rear panel, adjust the voltage selector to the correct voltage.
(
7 ) Use a screwdriver to remove the FUSE BRACKET. Ensure replacement fuses hear
identical specifications to the originals. The fuse bracket on the European model
doubles as a voltage selector. Read the upright value to determine the correct
voltage
setting.
(
8 ) The GROUND LIFT switch severs the ground to the chassis, eliminating
annoying background hum when the power amp is used in conjunction with other
equipment.
( 9 )
SPEAKERS
Connect speakers to these jacks for stereo operation. When using one speaker
cabinet per channel, ensure each speaker has a minimum power rating of 100 watts
and an impedance between 4 and 16 ohms. For two speakers per channel, each
cabinet must be rated at 8 ohms or greater.
,_
>’
c
11
(
10 ) SPEAKER PROTECT
Two fuses (3.15 A), one for each channel, protect speakers from damage due to
malfunctions e.g. direct current in the output jack. They also protect the power amp
from potential damage, e.g.
due to a defective power cable.
Before resuming operation, ensure:
l you replace blown fuses with ones hearing identical ratings.
l both, the connected speakers and speaker cables are fully functional.
l a qualified repairman inspects he CF 200 for possible damage.
( 6/7 )
page 8
(8) (9) (10)
( 11 ) BRIDGE MODE
The MODE switch ( 12 ) determines whether the CF 200 operates in the 2 x 1 OOW
stereo mode, or in the 200W mono mode. To avoid accidental switching between
01‘
modes, a plastic
lower screws are never removed simultaneously. When the MODE
coverplate
is screwed in position. Ensure that the upper and
switch
(
12 ) is
in the MONO BRIDGE position, the CF 200 operates as a mono 200W amp. Use
the two binding posts to connect speaker cabinets. Ideally, use cables with
terminals or banana plugs. Minimum impedance: 8 ohms.
Black binding post: negative. Red binding post:
plus
The INPUT RIGHT and the VOLUME RIGHT control are activated in the
BRIDGE MODE.
(
13 ) INPUTS
The input jacks are suitable for
preamps
or mixers. Both channels automatically
amplify the signal if only the INPUT RIGHT jack is accessed. In the BRIDGE
MODE, only the INPUT RIGHT is
activated.
SIGNAL ROUTING DIAGRAM
;; ;
;4i
. . . .
Poweramp
,&
_L_z ~~~ ,,
._-.. . . .
n_
I_
HUGHES & KETTNER CF 200
--__
CF 200
.-..a_
..__“._w
IIN] I
,_J
-*s_!
line Out left
i;;‘
i
Input left
D(@#y~ @J$/y$J[j’
Stereo Speaker Outs
left
I
i
GA~U~~Eru’,
Input
Cabinets e.g. HUGHES
CL112/GL212/GL412oderCR412
line Out Right
$
Input Right
Right
1
input
R
KETTNER
TECHNICAL DATA
Output power per channel: 70W at 8 ohms, 1 OOW at 4 ohms
Input sensitivity:
l
Stereo mode
l Bridge mode
1 V
eff
/0 cl bv
-
6dBV / 0.63 V
)
dBV/! V eff
eff
Input impedance:
50 kohms
IMPORTANT SAFETY INSTRUCTIONS!
BEFORE CONNECTING, READ INSTRUCTIONS
1.
Read all of these instructions
Save these instructions for later
2.
3
Follow
all
. .
Do
4.
Do
5.
fall. causing serious damage to the product.
6.
Slots and
\ entilation
overheating these openings must not be blocked or covered. This product should
not
This product should be operated from the type of power source indicated on the
7.
marking
dealer or local power company.
warnings
not use this product
not place this product on an unstable cart, stand or table. The product
openings
to ensure reliable operation
be placed in a built-in installation unless proper ventilation is provided.
label. If you are not sure of the type of power
and instructions marked on the product
near
in the cabinet and the back or bottom arc provided for
use
water
of
the product and to
protect
it from
available consult
may
your
‘I his product is equipped with a
8.
pin.
This plug will only tit into a grounding-type power outlet. This is a safety
feature. If you are
to replace your obsolete outlet. Do not defeat the purpose of the
Y.
Do
not allow
w
here persons will walk on the cord.
unable
anything
to rest on the
3-wire
grounding type plug. a plug having a third
to insert the plug into the outlet, contact your electrician
power
cord. Do
not
locate
grounding
this product
type plug.
10.
If an extension cord is
grounding- type and that
into the extension cord do
used with
this product make sure that it is a 3-wire
the total
of
the
amp ere ratings on the products plugged
not
exceed the extension cord ampere rating. Also
make sure that the total of all products plugged into the wall outlet does not
exceed I.5 amperes.
Il. Never push
objects
of
any
kind into this product through cabinet slots as may
touch dangerous voltage points or short out parts that could result in risk of fire
or electric shock. Never spill liquid of any kind on the product.
12.Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous
voltage
points or other risks. Refer all servicing
to service personnel.
13.
Unplug
thia
product Ii-om the wall outlet and refer servicing to qualilied service
personnel under the following conditions:
l When the
l If liquid has
l If the product has been exposed to rain or water
l If the product does not operate normally when the operating
power
cord or plug is damaged or frayed
been
spilled into
the
product
instructions are followed. Adjust only these controls that are covered by
the operating instructions since improper adjustment of other controls
may result in damage and wilt often require extensive work by a
qualified technician to restore the product to normal operation.
l If
the
product has
l If the product exhibits a distinct change in performance, indicating
a need of service!
been
dropped or the cabinet has been damaged
Selection of power supply cord
Use only a listed detachable power supply cord type SVT or SJT
minimum 18 AWG. 3 conductor, one end configured for NEMA 5-l 5
other end for
IEC 320/CEE
22!
14:
Fuses: For continued protection against risk of fire, replace fuses only
with same type and ratings
TO PREVENT THE RISK OF FIRE AND SHOCK HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO MOISTURE OR RAIN. DO NOT OPEN CASE; NO USER SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
page
1
1
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.