GENERAL
1. To ensure the success of the fixture installation, the following
instructions and diagram(s) should be read and understood.
2. All electrical connections must be made in accordance with the
National Electric code and local codes and ordinances. If you are
uncertain of the methods of installing electrical wiring and lighting
fixtures secure the services of a qualified licensed electrician.
3. TOOLS NEEDED: Blade screwdriver, phillips screwdriver,
slip joint pliers or small adjustable wrench, wire cutter/stripper,
electrical current tester, stepladder and electrical tape. NOTE: The
important safeguards and instructions outlined on this sheet are
not meant to cover all possible conditions and situations that may
occur. It must be understood that common sense, caution and care
are factors that cannot be built into any product. Caution and care
must be supplied by the person(s) installing, operating and
maintaining this lighting fixture.
INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH
THE LIGHTING FIXTURE IS TO BE ATTACHED. Move the
appropriate circuit breaker to the “off position or completely remove
the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to
which of the wires in the outlet box the fixture was attached. DO
NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE
BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING. In regular
circumstances the BLACK wire will be the “Hot” lead and the
WHITE wire will be the “Neutral” or “Common” lead. A GREEN or
BARE COPPER wire is the “Ground”. In older buildings it is always
good practice to reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or
octagon box. The box must be securely mounted to the structure
of the building.
FIXTURE PREPARATION
1. Remove the fixture, shades and parts bag(s) from the carton.
Before discarding the carton, double check packing to make
certain that all parts are found.
2. Assemble the stem, scroll and loop assembly to the fixture body.
FIXTURE INSTALLATION
1. Attach the crossbar to the outlet box. (The green screw should
face the floor)
2. Remove the threaded ring from the screwcollar loop. Fully
thread the loop onto the nipple. Thread the hex nut onto the
nipple and the nipple into the crossbar. Place the canopy over the
screwcollar loop and against the ceiling. Adjust the nipple so that
¼” of threads on the screwcollar loop extend beyond the canopy.
Tighten the hex nut against the crossbar.
3. Open end links of chain to the screwcollar loop. Close the top
link of chain. Hang the fixture on the chain at the desired height.
Remove the excess chain. Close the bottom link of chain.