Hudson Valley 4214 User Manual

4211,4214,4217
Hudson Valley Lighting, Inc. P.O. Box 7459 106 Pierces Road Newburgh, NY 12550 (800) 814-3993 www.hudsonvalleylighting.com
GENERAL:
1. To ensure the success of the fixture installation, the following instructions and diagram(s) should be read and understood.
2. All electrical connections must be made in accordance with the National Electric code and local codes and ordinances. If you are uncertain of the methods of installing electrical wiring and lighting fixtures secure the services of a qualified licensed electrician.
3. TOOLS NEEDED: Blade screwdriver, phillips screwdriver, slip joint pliers or small adjustable wrench, wire cutter/stripper, electrical current tester, stepladder and electrical tape. NOTE: The important safeguards and instructions outlined on this sheet are not meant to cover all possible conditions and situations that may occur. It must be understood that common sense, caution and care are factors that cannot be built into any product. Caution and care must be supplied by the person(s) installing, operating and maintaining this lighting fixture. INSTALLATION PREPARATION
1. TURN OFF THE ENTIRE ELECTRICAL CIRCUIT TO WHICH THE LIGHTING FIXTURE IS TO BE ATTACHED. Move the appropriate circuit breaker to the “off position or completely remove the fuse controlling the circuit.
2. If an existing fixture is being replaced, remove it and note to which of the wires in the outlet box the fixture was attached. DO NOT SEPARATE ANY OTHER WIRES THAT MAY BE IN THE BOX. DO NOT DAMAGE THE INSULATION OF OLDER WIRING. In regular circumstances the BLACK wire will be the “Hot” lead and the WHITE wire will be the “Neutral” or “Common” lead. A GREEN or BARE COPPER wire is the “Ground”. In older buildings it is always good practice to reconfirm the polarity of the wiring.
3. This fixture is designed to be mounted on a standard round or octagon box. The box must be securely mounted to the structure of the building.
FIXTURE INSTALLATION:
1. Attach the crossbar to the outlet box. (The green screw should face the floor).
2. Thread wire through stem , end nut and canopy.
3. Install stem. Install the adjustble nut to the post screw.
4.Trim excess wire to min. 6” beyond stem, strip to 5/8” and twist.
5. Fasten the bare copper fixture wire to the green or bare copper wire in the box or bare copper wire in the box to the crossbar with green screw provided. NEVER FASTEN THE GROUND WIRE TO THE BLACK OR “HOT” WIRE! FAILURE TO FOLLOW THIS INSTRUCTION COULD RESULT IN SERIOUS INJURY OR DEATH!
6. Fasten the white fixture wire to the white wire in the outlet box. Fasten the wires to together with an approved fastener(wire nut). Starting about 1” below the fastener, tightly wrap connection with the electrical tape so that the tape seals the end of the fastener. Make sure that there is no exposed wire or strands that could cause a dangerous short circuit!
7. Connect the black fixture wires to the black wire in the outlet box. Fasten the joined wires as in step 6.
8. Position and mount canopy to outlet box at ceiling with end nut.
9. Install the lamp ( light bulb).
10. Attach the glass to the body and secure by glass nut.
11. Restore power to circuit at breaker or fuse box.
TO SHORTEN CHAINS:
1. Unscrew adjustable nut and slide up.
2. Remove lock washer from chain.
3. Pop the chain loose from the post screw.
4. Remove the adjustable nut.
5. Shorten chain to desired length.
6. Slip chain back through adjustable nut.
7. Pop chain back into post screw.
8. Replace lock washer on chain.
9. Slide adjustable nut over post screw and tighten.
Loading...