99598 OPERATION
99599 OPERATION
Fill the canister with the desired amount of spray material. Reposition the sprayer on canister
top and snap clamp so it fits tightly. Check the switch to make sure it is "off" before plugging
into a 110/120 volt AC outlet. Once operating, the discharge rate of the sprayer may be
adjusted by turning the discharge control.
Spray Adjustment: The 99598 has an adjustment range of 1.5 to 5.3 gallons/hr.
Spray direction is variable through all degrees between 35 upward to 35 downward.
Wettable Powders: The 99598 sprays wettable powders at a maximum discharge rate of
5.3 gallons/hr. Preliminary testing is recommended to insure that desired rate is obtainable.
Shake or agitate solution periodically to keep powders in suspension.
Spray Patterns: The 99598 atomizes 95% of its output of less than 50 microns.
Average particle size is 20 microns.
After Use: To store the 99598 or change spray materials, detach the sprayer from the canister
and turn it "on" to flush out any spray material. The sprayer should be washed after which the
unit should be reassembled. After use with wettable powders, detach the canister, immerse
the supply tube in clear water and flush until no residue can be seen in the supply tube. Wash
the canister thoroughly.
Fill the canister with the desired amount of spray material. Reposition the sprayer on the
canister top and snap clamp so it fits tightly. Check the spray selector valve on the tube that
extends from the motor housing to the tank cover plate and set it according to the desired
spray pattern. "Heavy" setting is achieved with valve lever turned full left (counter-clockwise).
This covers the valve opening and pressurizes the canister. "Heavy" setting produces a dense
wetting spray, ideal for application of residual or surface type spraying. "Fine" setting is
achieved by turning valve lever full right (clock-wise). This opens the valve and allows air not
utilized in spray discharge to escape. "Fine" setting produces ultra fine particles, ideal for
flying insect control. Check the switch to make sure it is "off" before plugging into a 110/120
Volt AC outlet for 99599. Once operating, the discharge rate may be adjusted by turning the
discharge control at end of hose.
Spray Adjustment: The "ne" (unpressurized) setting has an adjustment rate of 1.5 to 3.5
gallons/hr. On "heavy" (pressurized) setting, the adjustment rate is 6 to 14 gallons/hr. Spray
direction is variable through manipulation of the discharge hose.
Wettable Powders: Preliminary testing is recommended to insure that desired rate is
obtainable. Shake or agitate solution periodically to keep powders in suspension.
After Use: When the unit is turned "off" after spraying, siphoning action may continue for
a moment, resulting in a solid stream of spray material. To prevent this, tip the nozzle up
straight as you switch "off" the motor, thus flushing any spray solution remaining in the
discharge line back into the canister. To store the 99599 or change spray materials, detach
the sprayer from the canister, immerse the supply tube in clear water, and flush until no
residue can be seen in the supply tube. Wash the canister thoroughly.