Hubbell Lighting - Columbia SLK22-40VWHE-EDU User Manual

SLK22
2'x2' LED Troer Retrot Kit
PROJECT INFORMATION
Project Name Type
FE ATURES
• Contemporary style LED retrot for existing 2x 2 prismatic or parabolic troer s with depth 3-1/8" or great er
• Two attractive architectural center lens choices
• 83 CRI stan dard or optiona l 90 CRI for color se nsitive applic ations
• Fully integrated hinged door assembly allows for easy installation and rapid troer conversion
• High ec iency acry lic center lens fea tures linear pr isms for high performance without pixilation
• High per formance re ector with ma tte white pain t standard
• Four LED col or choices
• Multiple lumen packages
• 60,000 h our LEDs at L80 (up to 150,00 0 projected l ife) for reduced maintenance
• Integral battery pack optional on most models
• Optional architecturally styled integr ation of daylight and occupancy sensor(s)
• Five year wa rranty (Terms an d Conditions ap ply)
Catalog No.
CONSTRUCTION
Retrot kit reectors, ends, frame and rails are manufac tured from die formed code gauge cold rolled steel. High transmission extruded acr ylic features linear prisms with custom frost for high ecacy and reduced pixelation.
SHIELDING
Removable lens f or easy access to LED module and electrical components.
FINISH
All reec tive surfaces are nished after fabrication with unique formula high reectiv ity matte white paint for soft, uniform indirect illumination.
IN STALLAT ION
Mounting rails and hardware are furnished with each luminaire f or easy installation. Fixture can be hinged from either side f or easy access to LED components and electrical components.
TROFFER COMPATIBILITY
Minimum dimensional requirements are listed bel ow. Columbia Lighting recommends a
trial installation prior to ordering project quantities.
Date
SLK retrot kits are designed to t into mos t parabolic and lensed troers with a housing depth of 3-1/8" or greater. This product is not suitable for air handling units.
CERTIFICATION
All luminaires are built to UL1598 and 2108 standards, and bear appropriate CSA labels. Damp location label standard. Emergenc y-equipped xture s labeled UL924 and Dry Location unless specied. Adheres to LM79, LM80, and TM21 industr y standards for photometrics and lifetime calculations. DesignLights Consortium (DLC) qualied. Please refer to the DLC website for spec ic product qualications at ww w.designlights.org
IC RATING
Maintains insulation contact (IC) rating of existing xture; note that IC label is void i f product is installed on site with a combination of both s tep­dimming (ESD) driver plus through wiring.
WARRANTY
Five year warranty (Terms and Conditions apply).
EXAMPLE SLK22-35HL-EDUORDERING INFORMATION
SLK
MODEL
SLK LED Troffer
Conversion Ki t
22
SIZE
22 2' x 2 '
Blank >80
CRI
9
>90
COLOR TEMP
1
30 3000K 35 3500 K 40 4000K 50 5000K
LUMEN OUTPUT
VW Very Low Watt
VWHE Very Low Wat t
High Efficacy
MW Medium Low Wat t
MWHE Medium Low Wat t
High Efficacy
LW Low Wat t ML Medium Lumen
MLHE Medium Lume n
High Efficacy
HL High Lumen
HLHE High Lumen High
Efficac y Very High Lumen
VL
Very High Lumen
VLHE
High Efficacy
See Produ ct Availability Table below.
ESD
ED1 0-10V 1% Dimming
LUTH Hi -lume 1%
LUT5 5-Series EcoSystem
Blank Curve
R Rectangular
DRIVER AVAILABILITY TABLE
VW VWHE MW MWHE LW ML MLHE HL HLHE VL VLHE
1
Not availab le with HE lumen ou tput.
2
Not available with ESD Step Dimming.
3
Only available with 0-10V Dimming (ED) Driver Option.
4
Limitat ions apply bas ed on lumen pack ages (see Dri ver Table).
5
Not available in 347V.
6
Registered trademark of Daintree Network s, used by permission
© 2017 Columbia Lighting, a division of Hubbell Lighting, Inc. Specications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com
E X X X X X X X X X X X
ED X X X X X X X X X X X ED1 X X X X X X X X X X X ESD X X X
LUT5 X X X LUTH X X X
347 X X X X X X
DRIVER
E Fixed Output
Step Dimming
ED 0-10V Dimming
EcoSystem LED driver wit h Soft-on, Fade-to-Black dimming
4,5
technology
4,5
LED driver
SHIELDING
VOLTAGE
U Universal
4,5
120 –277 VA C
347 347 V
OPTIONS
EL L14 Emergency B attery
Pack Insta lled, 1400 Lumens
LSP Lighting Su rge
ODP Occupanc y and
ZRE ControlScope®
2
Protector
Daylight Sensors,
3
Philips
6
compatible
LED / SLKPage 1/5 Re v. 04/19/17
SLK22
2'x2' LED Troer Retrot Kit
Product Availability 80 CRI
Lumen Package Shielding Lumens Input Watts LPW
SLK22-30VWG-EU Curve 1567 14 112
SLK22-30VWG-R-EDU Rectangle 1545 13 119
SLK22-30VWHEG-EU Curve 1530 13 118
SLK22-35VWG-EU Curve 1614 14 115
SLK22-35VWG- R-EDU Rectangle 159 8 13 12 3
SLK22-35VWHEG-EU Cur ve 15 76 13 121
SLK22-40VWG- EU Curve 1639 14 117
SLK22-40VWG-R-EDU Rectangle 1623 13 12 5
SLK22-40VWHEG-EU Curve 160 0 13 123
SLK22-50VWG-EU Cur ve 1785 14 128
SLK22-50VWG -R-EDU Rectangle 1666 13 12 8
SLK22-50VWHEG-EU Cur ve 1743 13 13 4
SLK22-30MWG-EU Curve 2049 18 11 4
SLK22-30MWG-R-EDU Rectangle 2016 18 112
SLK22-30MWHEG-EU Curve 2 010 17 118
SLK22-35MWG-EU Curve 2110 18 117
SLK22-35MWG-R-EDU Rectangle 2085 18 116
SLK22-35MWHEG-EU Curve 2070 17 122
SLK22-40MWG-EU Curve 2143 18 11 9
SLK22-40MWG-R-EDU Rectangle 2 118 18 11 8
SLK22-40MWHEG-EU Curve 2102 17 124
SLK22-50MWG- EU Curve 2334 18 13 0
SLK22-50MWG- R-EDU Rectangle 2174 18 121
SLK22-50MWHEG -EU Curve 2289 17 135
SLK22-30LWG-EU Curve 2689 23 117
SLK22-30LWG-R-EDU Rectangle 2662 23 116
SLK22-35LWG-EU Curve 2770 23 12 0
SLK22-35LWG-R-EDU Rectangle 2752 23 120
SLK22-40LWG-EU Curve 2813 23 122
SLK22-40 LWG-R-EDU Rectangle 2795 23 12 2
SLK22-50LWG-EU Curve 3063 23 133
SLK22-50LWG-R-EDU Rectangle 2870 23 125
SLK22-30MLG-EU Cur ve 3320 29 11 4
SLK22-30MLG-R-EDU Rectangle 3267 29 113
SLK22-30MLHEG-EU Curve 3293 28 118
SLK22-35MLG-EU Cur ve 3420 29 11 8
SLK22-35MLG-R-EDU Rectangle 3378 29 116
SLK22-35MLHEG-EU Curve 3391 28 121
SLK22-40MLG-EU Cur ve 3473 29 12 0
SLK22-40MLG-R-EDU Rectangle 3431 29 11 8
SLK22-40MLHEG-EU Curve 34 42 28 123
SLK22-50MLG-EU Cur ve 3781 29 13 0
SLK22-50MLG-R-EDU Rectangle 3522 29 121
SLK22-50MLHEG-EU Curve 3751 28 13 4
Product Availability 90 CRI
Lumen Package Shielding Lumens Input Watts LPW
SLK22-930VWG -EDU Curve 13 43 13 103
SLK22-930VWG -R-EDU Rectangle 1314 13 101
SLK22-935VWG-EDU Curve 1371 13 10 5
SLK22-935VWG-R-EDU Rec tangle 1342 13 103
SLK22-940V WG-EDU Curve 14 01 13 108
SLK22-940V WG-R-EDU Rectangle 1370 13 105
SLK22-950VWG-EDU Curve 1492 13 11 5
SLK22-950VWG-R-EDU Rectangle 1460 13 112
SLK22-930MWG-EDU Curve 174 4 18 97
SLK22-930MWG-R-EDU Rectangle 1715 18 95
SLK22-935MWG-EDU Curve 1781 18 99
SLK22-935MWG-R-EDU Rectangle 1751 18 97
SLK22-940MWG-EDU Curve 1819 18 101
SLK22-940MWG-R-EDU Rectangle 178 8 18 99
SLK22-950MWG-EDU Curve 1938 18 108
SLK22-950MWG-R-EDU Rectangle 190 5 18 106
SLK22-930LWG-EDU Curve 2286 23 99
SLK22-930LWG-R-EDU Rectangle 2263 23 98
SLK22-935LWG-EDU Curve 2339 23 102
SLK22-935LWG-R-EDU Rectangle 2 311 23 100
SLK22-940LWG-EDU Curve 2393 23 10 4
SLK22-940LWG-R-EDU Rectangle 23 61 23 103
SLK22-950LWG-EDU Cur ve 2528 23 110
SLK22-950LWG-R -EDU Rectangle 2515 23 109
SLK22-930MLG-EDU Cur ve 2822 29 97
SLK22-930MLG-R-EDU Rectangle 2778 29 96
SLK22-935MLG-EDU Cur ve 2888 29 100
SLK22-935MLG-R-EDU Rectangle 2836 29 98
SLK22-940MLG-EDU Cur ve 2955 29 102
SLK22-940MLG-R-EDU Rectangle 2897 29 100
SLK22-950MLG- EDU Curve 3121 29 108
SLK22-950MLG- R-EDU Rectangle 3086 29 106