UCT-5 Instructions
and Maintenance
Important: Read this before installing
and retain for future reference.
General: Read all warnings and information on carton(s) and product(s). This trim kit is suitable for damp locations in
ambient temperatures of 25 degrees C maximum and is to be used only with those luminaires listed above. These instructions do not attempt to cover all installation and maintenance situations. If additional information is required, contact your
nearest Hubbell representative for assistance.
Warning: Improperly installed fixtures can cause injury, shock, electrocution and fire hazards. Install and maintain with
qualified personnel to meet all applicable Codes and Ordinances. Turn power
maintenance. Ground properly and use appropriate wire connectors. Input voltage must be matched to the appropriate
ballast leads. Follow lamp and other equipment manufactures’ instructions. Installing electricians are responsible for evaluating local conditions and ensuring safe operation. Never remove the 1/4-20 volts to un-install.
UCT-5 Trim for use with Hubbell UCL or UCB ballast housings, UCO optical assemblies and Whiteway Civic
Series fixtures rated for 400 watts maximum with a minimum internal size of 19" by 9.06" by 13.75" high.
Lamp Code(s):
Installed by: Date:
OFF
prior to installation or performing any
General Installation Information:
1. Recommended tools: 3/8" socket and ratchet.
2. Use rated supply wire and utilize the units’ cable clamp to keep the wires away from the ballast and lamp socket.
3. Ensure existing housing does not leak from above and is secured properly to the canopy and can safely support the
additional weight of the retro-fit assembly. If not, seal and reinforce attachment system.
Installation Note: Turn power
1. Open, remove and discard lens frame assembly from existing fixture.
2. Remove lamp, reflector, socket/bracket, ballast (optional) and any hardware
from housing’s door flange.
3. If you are using the
additional ground wire approximately 5 inches below the canopy . If you are
upgrading the ballast
ballast and extend those leads along with an additional ground wire approximately 5 inches below the canopy .
4. Place wires through UCT panel’s wiring hole, hold panel against housing’s
door flange and lock the two suport arms (fig.1). Note:
5. Remove and discard Ballast Housing lid. Extend matching voltage and ground
leads with enclosed wires and secure with housing’s wire clamp. Note:
sure ballast voltage leads match the line voltage. Cap un-used leads.
6. Place wires over end wall. With wires facing wiring hole, insert housing side-
ways through the panel’s opening (fig.2), turn the housing with the bolts
down and rest the housing’s channels on the support rails (fig.3).
7. Fish wires through the wiring hole, complete the connections and push all
wires back through the wiring hole. Note: Wires should
canopy.
8. Position and orient Lens Assembly with a
direction where there
downwards). Place the lead-in cone (fig.4) into the ballast housings socket
cone and rotate assembly until the two bolt heads slide through the key
holes. Rotate unit clockwise until it locks into place; ensure the unit is secured.
9. Push latch up and lower lens. Adjust alignment if necessary and tighten
bolts with a 3/8" socket.
lens door .
Glare Control: See
existing ballast,
system, disconnect the supply wires from the existing
may
be a glare problem (reflectors can be adjusted
Ensure bolts are
UCL Instructions and Maintenance
OFF
prior to any work.
extend the leads for the socket and an
Do not pinch wires.
En-
not
extend below
non
-hinge/latch side facing the
tight. Install lamp tightly and close
sheet: “Optional”
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Maintenance: See
Replacement and Optical Assembly Replacement or Un-Install.
Hubbell Lighting, Inc., A Subsidiary of Hubbell Inc.
2000 Electric Way, Christiansburg, VA 24073-2500
Tel: 540-382-6111 FAX: 540-382-1526
UCL Instructions and Maintenance
sheet for Lamp
268-1221-9901