Hubbell Electric Heater J1686 Installation Manual

OPERATING AND MAINTENANCE
MANUAL FOR
ELECTRIC BOOSTER HEATER
ELECTRIC HEATER COMPANY
ASME ANSI/NSF5
2010 Edition
HUBBELL
ELECTRIC HEATER COMPANY
45 SEYMOUR STREET
P.O. BOX 288
STRATFORD, CT 06615
PHONE: (203) 378-2659 FAX: (203) 378-3593
INTERNET: http://www.hubbellheaters.com
-- IMPORTANT --
Always reference the full model number and serial number when calling the factory.
WARNING / CAUTION
1. Tank is to be completely filled with water and all air is to be vented before energizing.
2. Due to the rigors of transportation, all connections should be checked for tightness before
heater is placed in operation.
3. Safety relief valve must be installed in tapping provided.
4. The refractory material used in heating elements may absorb some moisture during
transit, periods of storage, or when subjected to a humid environment. This moisture absorption results in a cold insulation resistance of less than twenty (20) m egohm s. If this heater has been subjected to the above condition, each heating element must be checked for insulation resistance before energizing. Contact the factory for a replacement element.
5. KEEP AWAY FROM LIVE ELECTRICAL CIRCUITS.
Do not perform any maintenance, make any adjustments, or replace any components inside the control panel with the high voltage power supply turned on. Under certain circumstances, dangerous potentials may exist even when the power supply is off. To avoid casualties, always turn the power supply safety switch to off, turn the charge or ground the circuit before performing any maintenance or adjustment procedure.
6. The unit is designed to operate at pressure not more than 150 psi.
7. Generalized instructions and procedures cannot anticipate all situations. For this reason,
only qualified installers should perform the installations. A qualified installer is a person who has licensed training and a working knowledge of the applicable codes, tools, equipment, and methods necessary for safe installation of an electric resistance water heater. If questions regarding installation arise, check your local plumbing and electrical inspectors for proper procedures and codes. If you cannot obtain the required information, contact the company.
8. Water Quality Requirements – Recommended water hardness is 4 to 6 grains of
hardness per gallon (GPG). Water hardness above 6 GPG should be treated by a water conditioner (water softener or in-line treatment). Water hardness below 4 GPG also requires treatment to reduce potential corrosion. Excessive GPG will result in higher operating and maintenance costs and will reduce product longevity. Chlorides must not exceed 50 parts per million (ppm). Excessive chlorides will result in metallic corrosion and will reduce product longevity. Water treatment has been shown to reduce costs associated with de-liming the booster as well as reducing metallic corrosion. Product failure caused by these conditions is not covered under warranty. See warranty for complete details.
9. This water heater is not intended for space heating applications.
10. The water heater is factory set at 185°F for booster water heating applications. This
results in the possibility of a scalding water injury. A full thickness skin burn can occur in less than one second of exposure to water at this temperature.
2
TABLE OF CONTENTS
SECTION TITLE PAGE No.
I GENERAL DESCRIPTION AND CONSTRUCTION 4
II INSTALLATION AND START-UP 9 III SCHEDULED MAINTENANCE AND OPERATION 24 IV TROUBLESHOOTING 26
V SERVICING AND REPLACEMENT OF PARTS 32 VI SERVICE PARTS LIST 35
VII TORQUE VALUES 37
VIII WARRANTY INFORMATION 38
3
SECTION I - GENERAL DESCRIPTION AND CONSTRUCTION
GENERAL DESCRIPTION
This book describes a packaged electric booster heater that is typically used to provide 180°F sanitizing rinse water. The complete assembly consists of the storage tank, immersion electric heating element(s), electronic control module, safety relief valve, magnetic contactor(s), and any other required electrical operating control. Optional equipment may be supplied with your unit. Please consult the product packing list for details specific to your assembly. The unit is factory assembled, insulated, jacketed, wired, tested, and ready for electrical and plumbing service connections.
Storage
Model
J32.9 3 2.9 30 17 J161 16 1 10 5 J35.7 3 5.7 58 33 J161.5 16 1.5 15 8
J39.9 3 9.9 101 58 J162 16 2 20 11 J310.4 3 10.4 107 61 J163 16 3 30 17 J311.4 3 11.4 117 67 J164 16 4 41 23
J411 4 11.4 117 67 J166 16 6 62 35 J415 4 15 154 88 J167 16 7 72 41 J427 4 27 277 158 J169 16 9 92 53
J61 6 1 10 5 J1612 16 12 123 70
J61.5 6 1.5 15 8 J1613 16 13.5 138 79
J62 6 2 20 11 J1615 16 15 154 88 J63 6 3 30 17 J1618 16 18 185 105 J64 6 4 41 23 J1624 16 24 246 141 J65 6 5 51 29 J1627 16 27 277 158 J66 6 6 62 35 J1630 16 30 308 176 J67 6 7 72 41 J1636 16 36 369 211
J69 6 9 92 53 J1639 16 39 400 228 J610 6 10.5 108 62 J1640 16 40.5 415 237 J612 6 12 123 70 J1645 16 45 461 264 J613 6 13.5 138 79 J1654 16 54 554 316 J615 6 15 154 88 J1658 16 58.5 600 343 J618 6 18 185 105 J1664 16 64 656 375 J624 6 24 246 141 J1666 16 66 677 387 J627 6 27 277 158 J1668 16 68 697 398 J630 6 30 308 176 J1679 16 79 810 463 J636 6 36 369 211 J1681 16 81 830 474 J639 6 39 400 228 J1685 16 85 871 498 J640 6 40.5 415 237 J1686 16 86 882 504 J645 6 45 461 264 J1688 16 88 902 515 J654 6 54 554 316 J1690 16 90 923 527 J658 6 58.5 600 343
Capacity
(gallons)
kW
40°F
Rise
(GPH)
CAPACITY
70°F
Rise
(GPH)
Model
Storage
Capacity
(gallons)
kW
40°F
Rise
(GPH)
70°F
Rise
(GPH)
4
5
6
CONSTRUCTION TANK
The storage tank is designed, manufactured, and stamped in accordance with ASME section VIII Division 1. The tank is constructed of type 304L stainless steel for maximum tank longevity and fabricated by all welded construction and is designed for a maximum allowable working pressure of 150 psi (225 psi TP).
TANK CONNECTIONS
The heater is supplied with separate connections for the cold/warm inlet and the hot water outlet. Water entering the warm water inlet and leaving through the hot water outlet is evenly circulated by means of a diffuser within the tank. A ¾-inch FNPT connection is provided for mounting a combination safety temperature and pressure relief valve. An overflow line should be utilized from the relief valve outlet to a floor drain. See drawing for locations and sizes.
HEATING ELEMENT
The water heater is supplied with an electric immersion heating element assembly(s), composed of copper sheathed elements that are fitted into a brass 1½-12UNF screw plug with 1-7/8” hex. Each assembly is threaded into the tank and sealed with an o-ring gasket. See drawing for voltage and power ratings. Note that the J3 model element is a 1” NPS thread with a 1 ½” hex.
MAGNETIC CONTACTOR
The definite purpose magnetic contactor(s) is a heavy-duty resistive load type. The contactor supplies power to the heating element(s) based on the resistive load (non-inductive) of the heater only when the relay on the control board is closed, thereby pulling in the contacts until the desired temperature is reached. At this point, the contacts will drop out, which in turn disconnects power from the elements. Units with two contactors will turn on and off in stages.
CONTROL BOARD AND DISPLAY
The control board supplies all the necessary function for heater operation. These include control temperature, hi­limit cut-out, low water detection, and leak detection.
LOW VOLTAGE CONTROL TRANSFORMER
A control circuit transformer is supplied with all models rated greater than 240-volts. This component is used to step down the primary power supply (600, 480, 440, 415, 380, or 277) to 208/240­volts for safety when working with control circuits.
POWER CIRCUIT BREAKERS
When required by code, a magnetic power circuit breaker is supplied for circuit overload protection. The circuit breaker can be reset in the event of a current overload.
OUTER SHELL, INSULATION, AND SUPPORTS
The tank is encapsulated in high efficiency foam insulation meeting the requirements for UL 94 HF-1 rating. The protective shell is constructed of type 304 brushed stainless steel. NSF approved adjustable plastic legs are provided for support. Plastic legs for the J3 and J4 models are optional.
DIAL TEMPERATURE AND PRESSURE GAUGE
A combination temperature (30°-240° F / 0°-120°C) and pressure (0–200 psi / 0-1400 kPa) gauge with 3-inch dial is supplied with the unit for in-line installation (shipped loose). The connection is ½” NPT with a 2” long sensing probe. Dial temperature and pressure gauges for the J3 and J4 models are optional.
7
PRESSURE REDUCING VALVE
A bronze pressure reducing valve with built-in bypass is supplied with the unit. This valve is shipped separately for in-line installation. The ¾” NPT valve is adjustable from 25-psi to 75-psi. The inlet connection is supplied with a ¾” union by sweat connection. The outlet connection is ¾” female NPT. The set screw located at the top of the diaphragm adjusts the pressure, turn clockwise to decrease
the pressure and counter-clockwise to increase the
pressure. Pressure reducing valves for the J3 and J4 models are optional. DIELECTRIC UNIONS Dielectric unions are provided for the inlet and outlet nipples to isolate stray ground currents to reduce the possibility of galvanic corrosion. (Optional on the J3 and J4 Models).
OPTIONAL EQUIPMENT
Slide Brackets Available for the J6 Model only, these brackets allow for mounting the booster heater under a counter. See slide bracket diagram on page 9 for details. Shock Absorber The optional shock absorber can be installed between the booster and the dishwasher to reduce the harmful pressures resulting from quick closing dishwasher solenoid valves.
Legs In lieu of the standard black plastic legs, optional adjustable legs are available in stainless steel, die-cast nickel plated, and floor mount stainless steel. All optional legs are adjustable height type. Floor Mount Nickel Plated Stainless Steel Security Package For prison and other secure facilities a tamper resistant package is available. All external screws are spader type requiring a spader wrench for removal. Alternate Voltage Other voltages are available, including 277V single-phase, and 380V, 415V, and 440V three­phase. Consult the factory for details. Water Treatment System The optional water treatment system provides superior mineral scale prevention and corrosion control by feeding a special blend of scale control compounds into the warm water stream before the heater. The in-line system includes a clear cartridge housing to allow an operator to view the cartridge and determine when it needs replacement without the need to open the system. XB1 Low Temperature Interlock An optional in-line control board with separate manual setpoint (range: 165°F – 194°F) monitors the temperature of the water through the P65 probe and will trip a SPDT relay for customers’ remote applications. Remote Alarm Plug Adapter An optional plug adapter is available to provide a remote fault alarm signal through the J4 connector on the control board. See page 12 for installation details. 24-Volt Heater Interlock Adapter An optional plug adapter is available to interlock the heater via a 24-volt signal through the J1 connector on the control board. The 24-volt heater interlock adapter is supplied standard on the J3 model. See page 13 for installation details. (Only available with r23 or later software).
8
Protective Shrouds (J6 and J16 only) An optional durable protective plastic shroud is available to prevent damage to the booster due to water intrusion. The cover fits snugly over the entire booster and can be easily removed for cleaning and service.
SECTION II – INSTALLATION AND START-UP
WARNING / CAUTION
DO NOT TURN ON THE ELECTRIC POWER SUPPLY to this equipment until
heater is completely filled with water and all air has been released. If the heater is
NOT filled with water when the power is turned on, the heating elements will burn out.
For protection against excessive pressures and temperatures, local codes require the
installation of a temperature-and-pressure (T&P) relief valve certified by a nationally recognized laboratory that maintains periodic inspection of production of listed equipment of materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff for Hot Water Supply Systems. ANSI Z21.22-1971. THE CUSTOMER IS RESPONSIBLE TO PROTECT PROPERTY AND PERSONNEL FROM HARM WHEN THE VALVE FUNCTIONS.
All water heaters have a risk of leakage at some unpredictable time. IT IS THE
CUSTOMER'S RESPONSIBILITY TO PROVIDE A CATCH PAN OR OTHER ADEQUATE MEANS, SO THAT THE RESULTANT FLOW OF WATER WILL NOT DAMAGE FURNISHINGS OR PROPERTY.
Installation or service of this unit requires ability equal to that of a licensed tradesman
in the field.
The installation must conform to these instructions and any local authority having
jurisdiction. Grounding and electrical wiring connected to the unit must also conform to the latest version of the National Electric Code NFPA-70.
WATER HEATER PLACEMENT NOTE: For most effective operation, install the booster heater as close as possible to the
dishwasher. If the distance between the booster and the dishwasher exceeds NSF requirements, recirculation methods must be employed.
1. Place the heater on a solid, level foundation in a clean, dry location as near as possible
to the dish washing machine.
2. The water heater should be protected from freezing and waterlines insulated to reduce
energy and water waste.
3. Leave a minimum of 18” clearance for element withdrawal and control access.
4. Do not install in an area where flammable liquids or combustible vapors are present.
SLIDE BRACKETS FOR HANGING SUPPORT MOUNTING
1. Weld slide rails to
bottom of dishtable. Spacing should be 17” for J6 models up to 18kW and 22” for J6 models 24 to 58.5kW. J16 models are not designed for use with slide brackets.
9
2. Attach slide bracket angles to heater with #8 sheet metal screws. It will be necessary
to drill 1/8” holes into heater jacket for screw pilot holes.
3. Slide heater onto slide rails under dishtable.
PIPING INSTALLATION – See Diagrams
NOTES:
No check valve may be installed in the supply line to the booster.
All shut-off valves must be gate or ball valves – not globe valves.
To minimize heat loss and maximize efficiency, hot water piping should be insulated.
Teflon tape should be used on all NPT threaded pipe connections.
1. Install the factory supplied dielectric unions on the inlet and outlet piping.
2. Connect the cold/warm water inlet and hot water outlet to the appropriate connections
as shown; refer to the specifications for location and sizes. IMPORTANT – Be certain to connect the outlet piping to the final rinse and not to the wash tank. IMPORTANT (applies to J6 Models only) – Do not turn the entering warm water or exiting hot water nipples from their factory installed positions. The internal diffusers are aligned at the factory and turning the nipple will change the diffuser position and affect performance. Hubbell recommends that the inlet and outlet pipes are insulated to prevent excessive heat loss. IMPORTANT (applies to J6 Models only) – Do not apply heat directly to the entering warm water or exiting hot water nipples. If sweat connections are to be used, sweat tubing to the adapter before threading the adapter to the nipple on the heater. Any heat applied to the heater nipple will damage the internal plastic diffuser and affect performance.
3. Install water pressure regulator in the entering cold/warm water inlet line and adjust to
the pressure recommended by the dishwasher manufacturer. WHEN A STANDARD PRESSURE REGULATOR IS USED, (other than that purchased with the booster), it acts as a check valve and it is possible that thermal expansion will cause the relief valve to drip or occasionally blow off a small amount of water. To overcome this condition, it is recommended that a 3/8” by-pass arrangement with a horizontal check valve be installed around the pressure regulator. This will prevent annoyance caused by the relief valve dripping or blowing off. The pressure reducing valve is adjustable from 25 to 75 psi. The set screw located at the top of the diaphragm adjusts the pressure, turn clockwise
to increase the pressure and counter-clockwise to decrease the pressure.
4. Install the factory supplied in-line pressure and temperature gauge in the entering
cold/warm water line. NOTE: The temperature sensing element must be in the water stream.
5. Install the combination temperature and pressure safety relief valve in the tapping
provided. Note that this is required by law for safety considerations.
Install into provided tapping Manual Release Lever
Temperature Probe
Outlet to floor drain Temperature and Pressure Relief Valve
6. Install a relief valve overflow pipe to a nearby floor drain.
NOTE: Relief valve discharge piping limitations:
a. Termination to be plain end (no threads) b. Maximum 30-feet
10
c. Maximum four (4) elbows d. No reduction in line size e. No valve of any type to be installed between the relief valve and tank or in the
drain line
f. Termination to be 6-inches above the drain
7. A shock absorber is recommended in the hot water outlet line to soften the water
hammer caused by automatic dishwasher solenoid valves.
8. If supplied, install the optional second dial temperature and pressure gauge in the
outlet line. The temperature sensing element must be in the hot water stream and the gauge must be mounted upright.
FILLING THE HEATER
1. Open the valve to the cold water inlet and allow the heater and piping system to
completely fill, as indicated by a steady flow of water through the dishwasher rinse nozzles.
NOTE: Flush the tank at full flow for 10 minutes prior to putting into service.
ELECTRICAL INSTALLATION
1. Enter the base through the factory cut KO’s with properly sized feeder leads, See
Wiring Chart. Single-phase installations require two (2) leads. All Hubbell 3-phase heaters are intended for use with a 3-wire delta system plus ground. No neutral is required. For a 4-wire plus ground system, install 3 legs of power plus the ground and terminate the neutral leg.
2. Install these power leads into the box lugs on the power distribution block or magnetic
contactor, as required.
3. Connect incoming ground wire to ground lug supplied.
4. Check for proper grounding. Check for AC millivolts (mV) between the ground
connection at the booster and the inlet piping past the dielectric union (on the building side, not the booster side). There should be zero potential/millivolts (mV). If not zero, then the piping should be re-grounded.
5. All other electrical connections are made at the factory; therefore, no other electrical
connections are necessary.
6. Check all connections, including factory connections, for tightness.
OPTIONAL XB1 LOW TEMPERATURE INTERLOCK
1. If desired, the XB1 can be used as an alarm relay or a temperature interlock at a
setpoint other than the water temperature setpoint on the booster heater.
2. If the XB1 is not factory installed, mount the XB1 to the control panel, plug the P65
probe into the XB1, and plug the XB1 into the T1000 control board.
11
3. To set the XB1 setpoint, turn the potentiometer clockwise for a higher setpoint and
y
counter-clockwise for a lower setpoint. The range is adjustable between 150°F and 180°F.
4. Make connections as required to the relay terminal block. When the temperature drops
below the XB1 setpoint the relay is open between Normally Open (NO) and Common (C) and the LED will flash green. When the temperature is above the XB1 setpoint the relay is closed between NO and C and the LED will be solid green. Use NO an d C for low temperature interlock or high temperature alarm. Use Normally Closed (NC) and C for low temperature alarm. A red LED indicates an error.
LED
Relay
Note: Rating (resistive):
Terminal Block
Max.: 5A @ 120VAC 5A @ 24VDC
Temperature Adjustment Potentiometer
FOR REMOTE ON/OFF CONTROL
To remotely control the On / Off
Remote Relay by Customer
operation of the heater, it is recommended that a DPST
Wiring by
Customer
switch or relay (by others) be used to break both power legs (white and black wires) connected to the top two terminals of the J5 connector on the control board. See diagram at right.
Wiring from Contactor,
Power Distribution Block,
or Transformer
1 2 3 4
Controller J5 Connector
Use a NC (Normally Closed) relay to turn the booster ON when energizing the relay coil or to turn the booster OFF whe de-energizing the relay coil.
n
Red Wire to
Contactor #2
Yellow Wire to
Contactor #1
Use a NO (Normally Open) relay to turn the booster OFF when energizing the relay coil or to turn the booster ON when de-energizing the relay coil.
OPTIONAL REMOTE ALARM CONTACTS
1. If desired, the control board can be wired to a remote alarm to indicate a reset fault
condition. These fault conditions include over-temperature, no probe, and low water (when the configuration is set to manual reset).
2. This alarm can be wired to the J4 connector on the control board as shown below. To
facilitate this installation, an optional adapter, Hubbell P/N PLUG ADAPTER J4, can be purchased to provide wire connections.
J4 Connector
Note: Rating (resistive) Max. Switching Power:
60W, 62.5VA
Max. Switching Voltage:
220VDC, 250VAC Max. Switching Current: 2A Max. Carr
ing Current: 3A
PLUG ADAPTER J4
(NO) (NC)
12