CAUTION:
Before installing, make sure you are compliant with area classications, failure to do so may result in bodily injury,
death and property damage. Do not attempt installation until you are familiar with the following procedures. All
installation must comply with the applicable Electrical Code.
Make sure that the circuit is de-energized before starting installation or maintenance.
Verify that the installation is grounded. Failure to ground will create electrical shock hazards, which can cause
serious injury and or death.
Technical information, advice and recommendations contained in these documents is based upon information
that Killark believes to be reliable. All the information and advice contained in these documents is intended for
use only by persons having been trained and possessing the requisite skill and know-how and to be used by
such persons only at their own discretion and risk. The nature of these instructions is informative only and does
not cover all of the details, variations or combinations in which this equipment may be used, its storage, delivery,
installation, check out, safe operation and maintenance. Since conditions of use of the product are outside of the
care, custody and control of Killark, the purchaser should determine the suitability of the product for his intended
use, and assumes all risk and liability whatsoever in connection therewith.
3940 Dr. Martin Luther King Drive
St. Louis, MO 63113
P/N 00921378 FORM NO. K1378 10/11 ERO-6-008-11
Page 1 of 3

IMPORTANT
1. Luminaire is to be energized in hazardous
locations only after luminaire body has been
secured to Mount (Splice box) and Optics (Globe
or Refractor) as indicated in this document.
2. Verify that luminaire is grounded. Failure to
ground will create electrical shock hazards,
which can cause serious injury and or death.
3. Refer to luminaire nameplate for supply voltage,
ambient, supply wire, and other important data.
All unused conduit opening must be plugged.
Pipe sealant may be applied to threads in plugs
and securely tightened.
4. Great care should be taken when viewing
directly at the LED driven at high currents and
may be hazardous to your eyes
1. DIRECTION FOR INSTALLATIONS
1. Using the installation images on the left as
your guide, make sure the splice box (mount)
is securely installed. Pull supply wires though
conduit. (Refer to nameplate for proper supply
wire ratings) - Refer to Fig. 1 for details.
2. Luminaire Body is provided with gasket, two
leads and wire nuts. Connect Supply wire leads
from Fig 1 to Luminaire body corresponding
leads using wire nuts. Make sure gasket is
placed as indicated in Fig. 2.
3. Attach Luminaire body on to Splice Box (Mount)
by means of four #8 screws in threaded hole.
Make sure all the wiring is pushed inside the
mount. Now attach the 1/8 in. red silicone rubber
gasket inside luminaire body covering screws
and recessed under threaded area to prevent
from falling out. Optics (globe) is then attached
in the luminaire body tightly over gasket. Refer
to Fig. 3 for details.
4. Guard, if needed, can be threaded on to
luminaire body over optics.
5. Activate supplying circuit to assembled luminaire
to check for its operation.
3940 Dr. Martin Luther King Drive
St. Louis, MO 63113
P/N 00921378 FORM NO. K1378 10/11 ERO-6-008-11
Page 2 of 3

2. APPLICATION DATA
A complete xture consists of a LED Fixture Body
& a Splice Box & a Globe.
May also be provided with an optional Globe
Guard and/or Reector.
LED FIXTURE BODY SPLICE BOX GLOBE GUARD REFLECTOR
VSL1330, VSL 1324
or
VSL1630, VSL1624
VB-1; VB-2
VBC-1; VBC-2
VD4
VGA-1; VGA-2
VGC-1; VGC-2
VGH-1; VGH-2
VGX-1; VGX-2
VXA-1; VXA-2
VCG-100,VCGP100
VFG-100,VWG-100
VAMG-100,VCG-100
VAMGP-100,VBG-100
VGGP-100,VBGP-100
VRG-100,VRGP-100
VRSG-100,VPG-100
VPLCG-100,-R,-G,-B,-A
VAG-100
VAG-100R
May also be provided with Catalog No. VBA,
VFPS Adapter Mounting Plates or VFL Bracket
Mount Adapter.
Reectors are not for use with VD-4 Splice Box.
Suitable for Enclosures Type 3 & 4 when used with
VCGP-100 Heat Resistant Globe.
NOTE: Join or “lap” marks may form during the
pouring of molten glass in the globe manufacturing
process. It is not unusual for these marks to
become visible. This is a common and normal
occurrence for globes and does not affect
performance.
VPRSD-100
SAVE THESE SHEETS FOR FUTURE REFERENCES
3940 Dr. Martin Luther King Drive
St. Louis, MO 63113
P/N 00921378 FORM NO. K1378 10/11 ERO-6-008-11
Page 3 of 3