Ground Fault Products
Portable GFCI Products
Industrial Grade, Automatic and Manual Set GFCI Line Cords
Circuit Guard® Automatic Set
Portable GFCI Line Cords 15A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15A
6' (182.9 cm) GFCI line cord. GFP6C15A
25' (762.0 cm) GFCI line cord. GFP25C15A
15' (457.2 cm) GFCI power supply cord GFPOEMA*
with stripped leads.
Circuit Guard® Manual Set
Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15M –
3' (91.4 cm) GFCI line cord. – GFP3C20M
6' (182.9 cm) GFCI line cord. GFP6C15M –
25' (762.0 cm) GFCI line cord. GFP25C15M –
15' (457.2 cm) GFCI power supply cord GFPOEMM* –
with stripped leads.
50' (1524.0 cm) GFCI power supply with GFP50C15WM
Elastogrip
100' (3048.0 cm) GFCI power supply with GFP100C15WM
Elastogrip watertight straight blade.
Note: * Total length is 15' 4.5" (468.6 cm) including leads: green 4.5" (114.3), black and white 3.5" (88.9).
Circuit Guard® Manual Set
Twist-Lock Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
3' (91.4 cm) GFCI line cord. GFP3C15MTL GFP3C20MTL
Automatic Set GFCI
Automatically energizes or sets the GFCI for use
upon plug in and after the loss of primary power
(power failure or unplugging the device). After
a ground fault condition, unit must be reset by
pushing the reset button. This feature eliminates
the need for unit to be reset each time it is
plugged in or powered up. Ideal for equipment
intended for continuous use where a temporary
power failure is likely and undesirable. Examples
are pumps, pressure washers, portable signs or
lighting and engine heaters.
®
watertight straight blade.
Each pre-stripped .375" (9.5).
IP21
SUITABILITY
Manual Set GFCI
Requires the GFCI to be manually set for use by
pressing the reset button upon plug in and after
loss of primary power (power failure or unplugging
the device). Must be manually reset after a ground
fault condition. Ideal for applications where
operator injury might occur if equipment were to
restart after a power failure. Typical equipment
includes power drills, saws, lathes and grinders.
Portable GFCI Products Ground Fault Products
Straight Blade Twist-Lock
Input 15A NEMA 5-15P, 15A NEMA L5-15P HBL47CM20C,
20A NEMA 5-20P. 20A NEMA L5-20P HBL23CM11.
Output 15ANEMA5-15R(exceptGFPOEMM), 15ANEMAL5-15RHBL47CM29C,
20A NEMA 5-20R. 20A NEMA L5-20R HBL23CM13.
®
Specifications
Portable GFCI Line Cords
Trip Level 4 to 6 mA.
Trip Time .025 sec. nominal.
Frequency 60 Hz.
Voltage 120V AC +10% - 15%. Incorporates no voltage release feature.
Current 15A/20A.
Maximum Interrupting Capacity 2000A.
OperatingTemperature -35°Cto66°Cor-30°Fto150°F.
Maximum Humidity 95%.
Housing High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
Cord Type SJTW-A (UL), SJTW (CSA).
VisualFaultIndicationLightOn Indicatesfault.
Listing and Standards Meets UL943 Class A, UL File E41978, CSA Certified.
Code Meets all NEC
NEC® is a registere d trademark of the National Fire Protection Association (NFPA).
H-14 Dimensions in Inches (mm)
®
and CEC requirements.