Ground Fault Products
Portable GFCI Line Cords
Industrial Grade, Automatic and Manual Set
Circuit Guard® Automatic Set
Portable GFCI Line Cords 15A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15A
6' (182.9 cm) GFCI line cord. GFP6C15A
25' (762.0 cm) GFCI line cord. GFP25C15A
15' (457.2 cm) GFCI power supply cord with stripped leads. GFPOEMA*
GFP4C15A
GFP25C15A
Circuit Guard® Manual Set
Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
18" (45.7 cm) GFCI line cord. GFP4C15M –
3' (91.4 cm) GFCI line cord. – GFP3C20M
6' (182.9 cm) GFCI line cord. GFP6C15 M –
25' (762.0 cm) GFCI line cord. GFP25C15M –
15' (457.2 cm) GFCI power supply cord with stripped leads. GFPOEMM* –
50' (1524.0 cm) GFCI power supply with Elastogrip
watertight straight blade.
100' (3048.0 cm) GFCI power supply with Elastogrip
watertight straight blade.
Note: *Total length is 15' 4.5" (468.6 cm) including leads: green 4.5" (114.3), black and white 3.5" (88.9). Each pre-stripped .375" (9.5).
IP21
SUITABILITY
®
®
GFP50C15WM
GFP100C15WM
GFP6C15 M
GFPOEMM
GFP3C20MTL
Circuit Guard® Manual Set
Twist-Lock Portable GFCI Line Cords 15A 120V AC 20A 120V AC
Description Catalog Number
3' (91.4 cm) GFCI line cord. GFP3C15MTL GFP3C20MTL
Automatic Set GFCI
Automatically energizes or sets the GFCI for use upon
plug in and after the loss of primary power (power failure
or unplugging the device). After a ground fault condition,
unit must be reset by pushing the reset button. This
feature eliminates the need for unit to be reset each time it
is plugged in or powered up. Ideal for equipment intended
for continuous use where a temporary power failure is
Manual Set GFCI
Requires the GFCI to be manually set for use by pressing
the reset button upon plug in and after loss of primary
power (power failure or unplugging the device). Must
be manually reset after a ground fault condition. Ideal
for applications where operator injury might occur if
equipment were to restart after a power failure. Typical
equipment includes power drills, saws, lathes and grinders.
likely and undesirable. Examples are pumps, pressure
washers, portable signs or lighting and engine heaters.
Straight Blade Twi s t-Loc k
Input 15A NE MA 5 -15P,
20A NEMA 5-20P.
Output 15A NEMA 5-15R (except GFPOEMM),
20A NEMA 5-20R.
15A NEMA L5-15P HBL47CM20C,
20A NEMA L5-20P HBL23CM11.
15A NEMA L5-15R HBL47CM29C,
20A NEMA L5-20R HBL23CM13.
®
Specifications
Portable GFCI Line Cords
Tri p Leve l
Trip Time
Frequency
Voltage
Amperage
Maximum Interrupting Capacity
Operating Temperature
Maximum Humidity
Housing
Cord Type
Visual Fault Indication Light On
Listing and Standards
Codes
NEC® is a registere d trademark of the National Fire Protection Association (NFPA).
4 to 6 mA.
.025 sec. nominal.
60 Hz.
120V AC +10% – 15%. Incorporates no voltage release feature.
15A /20 A.
2000A.
-35°C to 66°C or -30°F to 150°F.
95%.
High-impact, UV stabilized PVC. UL 94V-0 flammability classification.
Meets UL and CSA watertight requirements. Adhesive bonded.
14/3 SJTW-A (UL), SJTW (CSA). Except GFP3C20M, GFP3C15MTL and
GFP3C20MTL are 12/3 SJTW.
Indicates fault.
Meets UL943 Class A, UL File E41978, CSA Certified.
Meets all NEC
®
and CEC requirements.
K-14
®
Wiring Device-Kellems