Hubbell PB3 BaseTrak Catalog Page

Non-Metallic Raceway
PB3 BaseTrak
Raceway, Device Boxes and Fittings
®
Description Color Length Catalog Number
Base and Cover
5 ft. (1.5m) and 10 ft. (3m) lengths.
PB3 BaseTrak
Description Color Catalog Number Catalog Number Catalog Number
Full Capacity Boxes
1-, 2- and 3-Gang boxes that allows full capacity from PB3 Raceway to box for either power or datacom applications.
See page R-63 for recommended single gang “KP” plate options.
®
Ofce
White
PB3FCIB
(1-Gang)
A: 4.38" (111.25) B: 4.80" (121.92) C: 3.17" (80.52)
Ofce White 5 ft.
10 f t.
A
B
PB3FCIB2G
(2-Gang)
A: 7.20" (182.88) B: 4.80" (121.92) C: 3.17" (80.52)
PB3BC5 PB3BC10
A: 1.63" (41.40) B: 4.50" (114.30)
PB3FCIB3G
(3-Gang)
A: 9.96" (252.98) B: 4.80" (121.92) C: 3.17" (80.52)
1-Gang In-Line Box
For switches, receptacles and
Device Boxes
communication devices. Provides ush look. See page R-63 for recommended plate options.
Internal Elbow
Full capacity 1¼ in. bend radius internal elbow.
Flat Elbow
Full capacity 1¼ in. bend radius
at elbow.
Splice Cover
For covering potential openings where two lengths of
raceway come
together.
Conduit Adapter/Ceiling Fitting
For connecting conduit to raceway. Also use for ceiling feeds. Has combination ½ in., ¾ in., 1 in., 1¼ in. and 1½ in.
trade size KOs.
Fittings
Ofce
White
Ofce
White
Ofce
White
Ofce
White
Ofce
White
PB3IND
A: 4.90" (124.46) B: 3.25" (82.55) C: 1.25" (31.75)
PB3IE* PB3IEBCA**
A: 4.36" (110.74) B: 4.72" (119.89) C: 4.36" (110.74)
PB3FE* PB3FEBCA**
A: 7.64" (194.66) B: 7.64" (194.66) C: 1.71" (43.43)
PB3SC*
A: 1.56" (39.62) B: 4.74" (120.40) C: 1.69" (42.93)
PB3CACF**
A: 4.72" (119.89) B: 5.22" (132.70) C: 6.30" (160.02)
2-Gang In-Line Box
For switches, receptacles and communi­cation devices. Barriers allow separation of power and datacom. Removal of barriers allows for expanded capacity. See page R-63 for recommended single gang “KP” plate options.
External Elbow
Full capacity 1¼ in. bend radius external elbow.
Tee
Full capacity 1¼ in. bend radius tee.
Safety Strap
Prevents potential tampering with PB3 BaseTrak cover. Can also be used as a splice cover.
Reducer
Reduces from PB3 BaseTrak Raceway to PW2 WallTrak Raceway.
Ofce White
Ofce White
Ofce White
Ofce White
Ofce White
PB3IND2G
A: 4.90" (124.46) B: 3.25" (82.55) C: 2.44" (61.98)
PB3EE* PB3EEBCA**
A: 6.48" (164.59) B: 4.72" (119.89) C: 6.48" (164.59)
PB3TCB CA* *
A: 7.37" (187.20) B: 7.08" (179.83) C: 2.72" (69.09)
PB3SS*
A: 1.50" (38.10) B: 6.01" (152.65) C: 1.74" (44.20)
PB3REDA**
A: 3.50" (88.90) B: 4.72" (119.89) C: 1.73" (43.94)
Transition Fitting
Transitions horizontal PB3 BaseTrak
to vertical PW2 WallTrak, PL1 LANTrak or
PP1 PremiseTrak.
Surface Panel Connector
For connecting PB3 Raceway
with surface type panel boxes.
Wire Clip
For holding conductors in place.
Note: *Cover only. **Base and Cover.
Dimensions in Inches (mm)
R-60
Ofce
White
PB3TRBC**
A: 3.22" (81.79) B: 7.28" (184.91) C: 2.42" (61.47)
Ofce
White
PB3SPCA*
A: 2.22" (56.39) B: 5.66" (143.76) C: 1.60" (40.64)
Ofce
PB3WC
White
®
Wiring Device-Kellems
Transition Fitting
Transitions from BT3 (old style) BaseTrak Raceway to PB3 (new style) BaseTrak Raceway.
End Cap
For closing end of PB3 BaseTrak Raceway.
Ofce White
Ofce White
BTPB3TF*
A: 2.22" (56.39) B: 5.66" (143.76) C: 1.35" (34.29)
PB3E CA*
A: 2.02" (51.31) B: 4.68" (118.97) C: 1.72" (43.69)
Loading...