Hubbell H-MOSS Ceiling Sensors Catalog Page

Wiring Device-Kellems
®
H-MOSS® Controls
Ceiling Sensors
Featuring Adaptive Technology
Adaptive Technology
• Adaptive technology - “Install and forget”
• All digital sensing technology
• Photocell for daylight harvesting and relay to interface with auxiliary systems such as HVAC (CRP models)
• Mounting base included with sensor
Dual (Ultrasonic and Passive Infrared)
Combines the excellent minor motion detection of ultrasonic with the outstanding passive infrared (PIR) long-range major motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Low voltage sensor with photocell and isolated relay Low voltage sensor
Note: Low voltage ATD ceil ing sensors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage pat terns and technical specifications.
• Non-volatile memory settings retained after power outage
• Low voltage units: 24V DC, 33mA
• Line voltage units: 20A, 120-277V
• 32kHz (ATD/ATU500C and CRP - 40kHz)
• cULus
2000 sq. ft. (360°) 2000 sq. ft. (360°) 2000 sq. ft. (360°)
1000 sq. ft. (180°) 1000 sq. ft. (180°) 1000 sq. ft. (180°)
500 sq. ft. (180°) 500 sq. ft. (180°)
White White White
White White White
White White
ATD2000CRP ATD2000C ATD2000CL
ATD1000CRP ATD1000C ATD1000CL
ATD 5 0 0CRP ATD 5 0 0C
ATD2000C
Series
ATD1000C/
ATD 5 0 0C
Series
Ultrasonic
Excellent minor motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Low voltage sensor with photocell and isolated relay Low voltage sensor
Note: Low voltage ATU ceiling se nsors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage pat terns and technical specifications.
2000 sq. ft. (360°) 2000 sq. ft. (360°) 2000 sq. ft. (360°)
1000 sq. ft. (180°) 1000 sq. ft. (180°) 1000 sq. ft. (180°)
500 sq. ft. (180°) 500 sq. ft. (180°)
White White White
White White White
White White
ATU2000CRP ATU2000C ATU2000CL
ATU1000CRP ATU1000C ATU1000CL
ATU 5 0 0CRP ATU 5 0 0C
Passive Infrared
Outstanding long range major motion detection.
Description Coverage Color Catalog Number
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Low voltage sensor with photocell and isolated relay Low voltage sensor Line voltage sensor
Note: Low voltage ATP ceil ing sensors must use a CU series control units. See page E-8 for details.
See pages E-19 and E-20 for coverage pat terns and technical specifications.
1500 sq. ft. (360°) 1500 sq. ft. (360°) 1500 sq. ft. (360°)
450 sq. ft. (360°) 450 sq. ft. (360°) 450 sq. ft. (360°)
White White White
White White White
ATP15 0 0 CRP ATP15 0 0 C ATP15 0 0 CL
ATP 6 0 0 CRP ATP 6 0 0 C ATP 6 0 0 CL
ATU2000C
Series
ATU1000C/
ATU 5 0 0C
Series
ATP15 0 0 C/
ATP 6 0 0 C
Series
Low Profile, Line Voltage Passive Infrared (PIR)
Outstanding long range major motion detection in a compact low profile housing.
Voltage Coverage Load Rating Color Catalog Number
120-347V AC with photocell and isolated relay
1500 sq. ft. 800W Inc. 1000W Fl. @ 120V AC
1800W Fl. @ 277V AC 2200W Fl. @ 347V AC
White LVPR15 0 0R
LVPR15 0 0R
E-7
Loading...