![](/html/77/77fb/77fb0ae457202963fd5b2b9f2375d12511f79fe4ab640bdb95f214ee9339d66d/bg1.png)
Features and Benefits
1.29"
(32.8)
1.07"
(27.2)
1.35"
(34.3)
3.28"
(83.3)
3.81"
(96.8)
2.60"
(66.0)
4.21"
(106.9)
Dual Function AFCI/GFCI Receptacles
• Cost effective solution conveniently located within living space; clearly visible,
easily resettable if necessary
• Dual functionality, interrupts power if a ground fault or arc fault is detected
• Safety feature prevents device from resetting if it can no longer provide
protection or is reverse wired
• Intuitive visual indication is provided for power (LED green ON); trip condition
(LED green OFF)
• Clear indication if unit can no longer provide protection (LED red ashes)
and will not reset
Dual Function
AFCI/GFCI Receptacles
Rating Color Standard Rating Color Standard
15A 125V
UL CSA
Black
Brown
Gray
Ivory
Light Almond
White
AFGF15TRBK
AFGF15TR
AFGF15TRGY
AFGF15TRI
AFGF15TRLA
AFGF15TRW
20A 125V
UL CSA
Black
Brown
Gray
Ivory
Light Almond
White
AFGF20TRBK
AFGF20TR
AFGF20TRGY
AFGF20TRI
AFGF20TRLA
AFGF20TRW
Specications
Ratings
Amperage 15 Amp/20 Amp
Feed-thru 20 Amp Protection
Voltage 120V AC (+10% to -15%)
(102V to 132V)
Horsepower (1) @ 120V AC
Flammability Rated V2 per UL 94
Operating (-35°C to 66°C) or
Temperature (-30°F to 150°F)
Product Dimensions Inches (mm)
1.31"
(33.3)
3.81"
(96.8)
3.28"
(83.3)
1.68"
(42.7)
4.21"
(106.9)
2.60"
(66.0)
Certifications
UL1699A E485931
UL498 Receptacle
UL943 GFCI
UL Fed Spec WC-596
CSA Standard C22.2 No. 42
CSA Tech Letter No. M-02A
NEMA WD-6
15 Amp 20 Amp
1.35"
(34.3)
1.29"
(32.8)
1.07"
(27.2)
1.43"
(36.3)
1.29"
(32.8)
1.07"
(27.2)
Construction
Termination Back and Side
Terminal #14-10 AWG
Grounding Autoground Clip
Indicators Power, Trip, End of Life
Configuration 2 Pole, 3 Wire
NEMA 5-15R, 5-20R
K-11