H-MOSS® Controls
OPTIMYZER® High Bay Controls and Daylight Harvesting
Multi-Level Relays
Description Catalog Number
Enclosed independent control for multiple ballast light xtures from one existing wall switch,
bi-level; 120/208-277V AC
Enclosed independent control for multiple ballast light xtures from one existing wall switch,
tri-level; 120/208-277V AC
Enclosed 10 Amp SPDT Relays
Description Catalog Number
Enclosed relay 10 Amp SPDT with 10-30V AC/DC/120V AC coil AAR10C120
Enclosed relay 10 Amp SPDT with 10-30V AC/DC/208-277V AC coil AAR10C277
OPTIMYZER® High Bay Controls
• Digital passive infrared (PIR) sensor
• Multiple (single and dual) output versions
• Single and dual timer operation
• Low-profile design
• Supports mounting heights up to 40 ft
• Area and aisle coverage
• Universal voltage (120/277/347V AC) models available
• No minimum load
Standard
Description Voltage Catalog Number
Fluorescent high bay PIR sensor, 1 relay 120-347V AC HMHB21U
Fluorescent high bay PIR sensor, 2 relays 120-347V AC HMHB22U
Fluorescent high bay PIR sensor, 1 double pole relay 208/240V AC HMHB23A
Fluorescent high bay PIR sensor, 1 double pole relay 480V AC HMHB23B
Fluorescent high bay PIR sensor 24V DC HMHB2LV*
AARBL2
AARBL3
AARBL2
AAR10C277
HMHB21U
Daylight Harvesting (With Photocells)
Description Voltage Catalog Number
Fluorescent high bay PIR sensor, 1 relay with photocell 120-347V AC HMHB21UP
Fluorescent high bay PIR sensor, 2 relays with photocell 120-347V AC HMHB22UP
Fluorescent high bay PIR sensor, 1 double pole relay with photocell 208/240V AC HMHB23AP
Fluorescent high bay PIR sensor, 1 double pole relay with photocell 480V AC HMHB23BP
Fluorescent high bay PIR sensor with photocell 24V DC HMHB2LVP*
See pages E-20 for coverage patterns and technical specifications.
OPTIMYZER® Accessories
Description Catalog Number
High bay mounting extension adapter HMHBSA
External daylight control HMHBEP
Daylight Harvesting
• Multiple calibration options
• Selectable 3- or 8-second dimming rate
Description Voltage Catalog Number
Single zone continuous automatic dimming control
Indoor photocell
Outdoor photocell
Atrium photocell
Skylight photocell
Control module
Daylight tracker with on/off control
Daylight tracker with dimming control
Note: *For use with CU se ries control u nits. See page E-10 for details.
†For use with 0-10V DC dimming ballasts.
For use with DHCM and CU series control units.
• Low-profile design
• Light-sensitivity range of 0–500 foot candles
10V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
24V DC
DHADC
DHIP
DHOP
DHAP
DHSP
DHCM
DHT*
DHTD
†
†
HMHBSA
DHADC
DHIP, DHOP
DHAP, DHSP
DHCM
DHT
E-9