Hubbell D, D1, D10, D20, D30 Maintenance Manual

...
OPERATING AND MAINTENANCE MANUAL FOR
ELECTRIC STAINLESS STEEL HEATER
FOR DEIONIZED (DI) WATER
ELECTRIC HEATER COMPANY
HUBBELL
ELECTRIC HEATER COMPANY
P.O. BOX 288
STRATFORD, CT 06615
PHONE: (203) 378-2659 FAX: (203) 378-3593
INTERNET: http://www.hubbellheaters.com/
-- IMPORTANT --
Always reference the full model number and serial number when calling the factory.
WARNING / CAUTION
1. Tank is to be completely filled with water and all air is to be vented before energizing.
2. Due to the rigors of transportation, all connections should be checked for tightness before heater is placed in operation.
3. Safety relief valve must be installed in tapping provided.
4. The refractory material used in heating elements may absorb some moisture during transit, periods of storage, or when subjected to a humid environment. This moisture absorption results in a cold insulation resistance of less than twenty (20) megohms. If this heater has been subjected to the above condition, each heating element must be checked for insulation resistance before energizing. A low megohm condition can be corrected by removing the terminal hardware and baking the element in an oven at 350°F -700°F for several hours or until the proper megohm reading is obtained.
5. KEEP AWAY FROM LIVE ELECTRICAL CIRCUITS. Do not perform any maintenance, make any adjustments, or replace any components inside the control panel with the high voltage power supply turned on. Under certain circumstances, dangerous potentials may exist even when the power supply is off. To avoid casualties, always turn the power supply safety switch to off, turn the charge or ground the circuit before performing any maintenance or adjustment procedure.
6. The unit is designed to operate at pressure not more than 150 psi.
7. Generalized instructions and procedures cannot anticipate all situations. For this reason, only qualified installers should perform the installations. A qualified installer is a person who has licensed training and a working knowledge of the applicable codes regulation, tools, equipment, and methods necessary for safe installation of an electric resistance water heater. If questions regarding installation arise, check your local plumbing and electrical inspectors for proper procedures and codes. If you cannot obtain the required information, contact the company.
2
TABLE OF CONTENTS
SECTION TITLE PAGE #
I GENERAL DESCRIPTION AND CONSTRUCTION 5
II INSTALLATION 9
III SCHEDULED MAINTENANCE AND OPERATION 12
IV TROUBLESHOOTING 14
V SERVICING AND REPLACEMENT OF PARTS 16
VI MISCELLANEOUS CHARTS AND FORMULAS 23
3
4
SECTION I - GENERAL DESCRIPTION AND CONSTRUCTION
GENERAL DESCRIPTION
This booklet describes an electric heater designed specifically for use in deionized (DI) water applications. The complete assembly consists of a type 316L stainless steel storage tank, type 316L stainless steel immersion electric heating element(s), thermostat, safety relief valve, safety high temperature cut out, magnetic contactor(s), and any other required electrical operating control. Optional equipment may be supplied with your unit. Please consult the product drawing for details specific to your assembly. The unit is factory assembled, insulated, jacketed, wired, tested, and ready for electrical and plumbing service connections.
CONSTRUCTION
TANK
The storage tank is constructed of type 316L stainless steel for maximum tank longevity. The tank is formed by all welded construction and is designed for a maximum allowable working pressure of 150 psi (300 psi TP). As an optional, the tank may be supplied with a passivated / electropolished finish.
TANK CONNECTIONS
The heater is supplied with separate connections for the cold water inlet and the hot water outlet. Water entering the cold water inlet is deflected by means of a baffle within the tank. A ¾-inch FNPT connection is provided for mounting a combination safety temperature and pressure relief valve. An overflow line should be utilized from the relief valve outlet to a floor drain. See drawing for locations and sizes.
HEATING ELEMENT
The water heater is supplied with an electric immersion heating element assembly(s), composed of type 316L stainless steel sheathed elements that are welded into a stainless steel flange. Each assembly is fastened to a corresponding tank flange using a Teflon gasket and four (4) 3/8-16 x 1-inch long hex head steel bolts and nuts. See drawing for voltage and power ratings.
5
CONTROL THERMOSTAT
The water heater is supplied with a single stage immersion thermostatic switch that is installed and wired at the factory. The thermostat can be adjusted through a range of 100° - 195° F, (an optional low range, 30° ­110° F, is available), and is adjustable with a flat tip screwdriver. Other thermostatic controls are available, see Options below.
TEMPERATURE HIGH LIMIT SWITCH
As a safety device, either a surface mounted high temperature cut-off switch with manual reset, factory set at 205° F, or an optional immersion high temperature cut-off switch with manual reset, adjustable through a range of 100° - 240° F, is provided. In the event of an over-temperature condition, the thermostat will disengage the power from the system. The high limit must be manually reset thereafter to restart the heater.
Manual Reset
Surface Mounted High Temperature Cut-Off Switch Immersion High Temperature Cut-Off Switch
MAGNETIC CONTACTOR
The magnetic contactor(s) is a heavy-duty resistive load type rated for 100,000 cycles. The contactor supplies power to the heating element(s) based on the resistive load (non-inductive) of the heater only when the thermostatic switch is engaged, thereby pulling in the contacts until the desired temperature is reached. At this point, the contacts will drop out, which in turn disconnects power from the elements. Magnetic contactors are installed only on units rated greater than 6kW.
6
OUTER SHELL AND INSULATION
The tank is encapsulated in 2-inches of high-density fiberglass insulation. The protective shell is constructed of galvaneel and is coated with a durable silver hammertone finish.
OPTIONS
The following optional features may be included in your water heater. Reference included drawing specific to your heater for further details.
Low Water Cut-Off
Used as a safety device, the float type (316 stainless steel) low water cut-off is used to detect a low water situation and disengage the operating coils in the magnetic contactor(s). Once the condition is remedied, the low water cut-off switch is automatically reset. This type of low water cut-off uses a 316 stainless steel float.
Fused Low Voltage Transformer
A fused low voltage transformer may be supplied. This option is provided only in 480-volt systems with low water cut-offs to step down the voltage to 240-volt for safety when working with control circuits. As an option, a transformer may be installed on any unit to step down the voltage to 120-volts
Stainless Steel Outer Jacket
An optional stainless steel outer jacket may replace the standard galvaneel jacket.
Optional Connections
Flanged inlet and outlet connections (150#) Threaded inlet and outlet connections (1 ½”, 2” MNPT) Sanitary Connections
NEMA 4 or NEMA 4X Electric Control Panel
A NEMA 4 control panel may be supplied to provide watertight construction for installation in “wet” areas.
7
Individually Fused Elements
To prevent the possibility of damage to control circuits and other elements in case of electrical overloads, fuses may be supplied for each circuit. Two types of fuses may be used; a type NON for voltages less than 250-volt or type JJS for voltage less than 600-volt.
Type JJS Type NON
Digital Display
A 1/16 DIN electronic temperature control package may be installed. A separate manufacturer’s operating manual will be supplied with the unit.
Stainless Steel Pressure-Only Relief Valve Optionally, a ¾” NPT, type 316 stainless steel pressure-only relief valve may be supplied, as shown below.
8
SECTION II – INSTALLATION
WARNING / CAUTION
DO NOT TURN ON THE ELECTRIC POWER SUPPLY to this equipment until heater is completely filled with water and all air has been released. If the heater is NOT filled with water when the power is turned on, the heating elements will burn out.
For protection against excessive pressures and temperatures, local codes require the installation of a temperature-and-pressure (T&P) relief valve certified by a nationally recognized laboratory that maintains periodic inspection of production of listed equipment of materials, as meeting the requirements for Relief Valves and Automatic Gas Shutoff for Hot Water Supply Systems. ANSI Z21.22-1971. THE CUSTOMER IS RESPONSIBLE TO PROTECT PROPERTY AND PERSONNEL FROM HARM WHEN THE VALVE FUNCTIONS.
All water heaters have a risk of leakage at some unpredictable time. IT IS THE CUSTOMER'S RESPONSIBILITY TO PROVIDE A CATCH PAN OR OTHER ADEQUATE MEANS, SO THAT THE RESULTANT FLOW OF WATER WILL NOT DAMAGE FURNISHINGS OR PROPERTY.
WATER HEATER PLACEMENT
1. Place the heater on a solid foundation in a clean, dry location nearest to the point of hot water use.
2. The water heater should be protected from freezing and waterlines insulated to reduce energy and water waste.
3. Leave a minimum of 18” clearance for element withdrawal, if necessary.
4. Do not install in an area where flammable liquids or combustible vapors are present.
PIPING INSTALLATION
NOTE:
galvanic and stray current is the installation of dielectric fittings/unions. The installation of these fittings is the responsibility of the installing contractor.
The most effective means for preventing deterioration from accelerated corrosion due to
1. Connect the cold water inlet and hot water outlet to the appropriate connections as shown; refer to the drawing for location and sizes.
2. Install the combination temperature and pressure safety relief valve in the tapping provided. Note that this is required by law for safety considerations.
9
Outlet to floor drain Install into provided tapping
Manual Release Lever
Temperature Probe
Temperature and Pressure Relief Valve
3. Install a relief valve overflow pipe to a nearby floor drain. CAUTION: No valve of any type should be installed between the relief valve and tank or in the drain line.
FILLING THE HEATER
1. Open the pressure relief valve test lever to allow air to escape.
2. Open the valve to the cold water inlet and allow the heater and piping system to completely fill, as indicated by a steady flow of water from the relief valve.
ELECTRICAL INSTALLATION
1. Enter electric enclosure with properly sized feeder leads. Single-phase installations require two (2) leads; three phase installations require three (3) leads.
2. Install these power leads into the box lugs on the terminal block or magnetic contactor. See wiring diagrams below.
3. Torque screws per torque chart included in Section VI.
4. All other electrical connections are made at the factory; therefore, no other electrical connections are necessary.
10
THERMOSTAT SETTING (BULB AND CAPILLARY IMMERSION TYPE)
The bulb and capillary type thermostat is immersed in a Type 316L stainless steel well in the storage vessel. The full thermostat range is 100-240°F, but should not be operated over 195°F. There is a setting screw, which can be locked at a particular setting to prevent an operator from turning the dial beyond a determined temperature point. To change the locking set screw open the thermostat cover and follow the printed directions on the inside of the cover. To change the operating temperature setting on the thermostat within the allowed range simply insert a screwdriver in the slot and make the appropriate adjustment to the temperature setting according to the desired point on the dial.
FINAL CHECKS
1. Check all connections for tightness.
2. Ensure that all the above steps are completed
3. After the water is heated for the first time, monitor the water temperature as described in Section III, Quarterly Inspection.
11
SECTION III - SCHEDULED MAINTENANCE AND OPERATION
WARNING / CAUTION
Before performing any maintenance procedure, make certain power supply is OFF and cannot accidentally be turned on.
MAINTENANCE AND OPERATION
The water heater is automatic in its operation. It will maintain a full tank of water at the temperature setting of the thermostat. The water heater should not be turned on without first making sure that the tank is full of water and that all air has been released.
FREEZING
The tank should be fully drained in the event the electricity has been turned off and if there is danger of freezing.
QUARTERLY INSPECTION
1. Monitor thermostat
a. Let water heater completely heat to a designated thermostat setting. b. After thermostat satisfies (that is, when the thermostat actually clicks off), draw water from
heater.
c. Compare water temperature of drawn water to the temperature setting of the thermostat when
it satisfies. Normal variation between the two points is approximately + 5°F.
d. If these two readings do not coincide within acceptable tolerances and verification has been
made of the accuracy of the temperature-reading gauge, replace the thermostat.
2. Lift test lever on relief valve and let water run through valve for a period of approximately 10 seconds. This will help flush away any sediment that might build up in water passageways.
3. Inspect element flange for leakage as follows:
a. Shut off Power Supply. b. Remove element housing cover. c. Visually inspect heating element gasket for evidence of leaks. d. Rub finger around gasket that is between the heating element and tank flange for any
evidence of moisture. If moisture is present or a water drip is observed, follow procedure outlined in Section V.
4. Check for loose electrical connections. Tighten as necessary.
12
ANNUAL INSPECTION
1. Flush tank as follows
a. Shut off power supply. b. Close valve on hot water outlet piping. c. Open valve on drain piping. d. Cold water inlet line pressure will be strong enough to flush sediment from the bottom of the
tank out through the drain. Let water run for 3-4 minutes. e. Close drain valve. f. Open hot water valve. g. Turn power supply ON.
13
Symptom Probable Cause Corrective Action / Remedy
No hot water
SECTION IV – TROUBLESHOOTING
Circuit breaker tripped at source. Reset circuit breaker. Blown fuse in transformer, if installed. Circuit breaker at control cabinet tripped, if installed. Blown fuse in element fuse block, if installed. High limit switch tripped. Reset high limit switch.
Loose wires. Tighten wires. Torque screws
Heating element inoperable. Check heating element
Low line voltage. Have source electrical system
Faulty thermostat. Move thermostat dial through
Faulty low water cut-off, if installed.
Magnetic contactor does not energize.
Replace fuse.
Reset circuit breaker.
Replace fuse.
per torque chart included in Section VI.
operation by clamping an Amprobe around each wire to the element. The ampere reading should agree with the nameplate ‘AMP’ figure.
checked by an electrician.
full range. A definite ‘click’ should be heard. If not, replace thermostat. Check to see if tank is full of water. If not, fill tank. If problem continues and tank is full, check for continuity between the common and normally open contact of the relay board. If continuity is not observed, replace low water cut-off. Replace complete magnetic contactor. Because of the design of this particular contactor, it is more desirable to replace complete control rather than rebuilding coil, contacts and springs, etc.
14
Water temperature below settings at all times
Relief valve discharges continuously
Faulty thermostat. Check thermostat adjustment.
Monitor thermostat as described in Section III, Quarterly
Inspection. Replace if necessary. Heating element not working on all phases
Check to see that heating
element is working on all
phases, by checking the
resistance (ohms) value for each
element and comparing with the
chart included in Section VI. Blown fuse in element fuse block,
Replace fuse. if installed. Heater improperly sized Verify heater is properly sized
for the flow rate and temperature
rise of your system. See formulas
included in Section VI. Replace
elements with proper size as
necessary. Excessive temperature or pressure in tank
Temperature and pressure relief
valves are made to operate if the
water temperature exceeds
210°F or water pressure exceeds
the pressure rating of the safety
relief valve. If trouble is
excessive temperature, then
thermostat is not shutting off at
the right setting and thermostat
must be replaced.
15
SECTION V - SERVICING & REPLACEMENT OF PARTS
WARNING / CAUTION
Before servicing or replacing any part make sure to turn the power supply switch to the OFF position.
SURFACE TEMPERATURE HIGH LIMIT CUT-OFF
1. Disconnect power from unit.
2. Remove access cover.
3. Disconnect the four (4) 14 gauge wires.
Control Wires
4. Remove the two (2) mounting screws.
5. Replace control and install new high limit switch by performing above steps in reverse order. See wiring diagram included with drawing for assistance.
Mounting Screws
16
IMMERSION TEMPERATURE HIGH LIMIT CUT-OFF
1. Disconnect power from unit.
2. Remove access cover.
3. Remove high limit cover screw and cover.
Cover
Cover Screw
Reset Switch
4. Disconnect the two (2) 14 gauge wires.
Wires
Capillary Tube
5. Remove capillary tube and bulb from thermowell
6. Remove two (2) mounting screws.
Mounting Screws
7. Remove control and install new high limit switch by performing above steps in reverse order. (Note: Be sure to place capillary tube into slot in base prior to installing cover.)
17
HEATING ELEMENT
1. Disconnect power from unit.
2. Shut off incoming water supply.
3. Attach hose to drain connection.
4. Lift manual release lever on relief valve to let air into system or break union on outgoing water line.
5. Drain water from tank.
6. Disconnect the wires from the heating element terminals.
7. Remove the 3/8-16 nuts. Tank Flange
Element Terminals
Nuts
8. Withdraw element assembly and remove gasket.
Gasket
Element Assembly
9. Install new gasket and insert new heating element.
10. Rewire element according to the voltage and phase rating of the unit as shown below.
11. Fill tank and check around gasket for any leaks.
18
19
IMMERSION THERMOSTAT
1. Disconnect power from unit.
2. Remove access cover and locate thermostat.
3. Remove high limit cover screw and cover.
Cover
Cover Screw
4. Disconnect the two (2) 14 gauge wires.
Wires
Capillary Tube
5. Remove capillary tube and bulb from thermowell.
6. Remove two (2) mounting screws.
Mounting Screws
7. Replace thermostat using reverse procedure. (Note: Be sure
to place capillary tube into slot in base prior to installing cover.)
20
MAGNETIC CONTACTOR
1. Disconnect power from unit.
2. Disconnect line and load wires to contactor.
3. Disconnect two (2) 14 gauge control circuit wires.
Control Wires
Line Wires
Load Wires
4. Loosen two (2) holding screws and remove contactor.
Mounting Screws (Bottom screw not shown)
5. Replace with new contactor using reverse procedure.
21
RELIEF VALVE
1. Disconnect power from unit.
2. Shut off incoming water supply.
3. Lift test lever on relief valve to relieve pressure in tank.
4. Disconnect overflow piping.
5. Unscrew relief valve, remove assembly and replace with new one.
6. Connect overflow piping.
7. Turn on incoming water supply and check for leaks.
8. Turn safety switch to ON position.
Test Lever
Overflow Piping Outlet
Tank Connection
Temperature Probe
22
SECTION VI – MISCELLANEOUS CHARTS AND FORMULAS
ELEMENT CHART
Element Part #
50-38683SSN 5 6 8 13" 27.9 9.3 27.9 18.7 60-38683SSN 6 8 10 13" 21.6 7.2 21.6 14.5 70-38683SSN 8 10 12 13" 17.1 5.7 17.1 11.5 80-38683SSN 90-38683SSN 12 15 20 15" 12.1 4.0 12.1 8.1 100-38683SSN 110-38683SSN 17.3 ---- ---- 15" 7.5 2.5 7.5 5.0
FORMULAS
Power (kW)
208V 240V 480V
10
15
12 15 13" 14.4 4.8 14.4 9.6
20 ---- 15" 9.1 3.0 9.1 6.1
Immersion
Length
Hairpin
Resistance (Ohms)
1 Φ 3 Φ DELTA 3 Φ WYE
23
TORQUE VALUES
BOLT SIZE
4-40
18-8 S/S
IN.-LBS.
BRASS
IN.-LBS.
SILICON BRONZE
IN.-LBS.
5.2 4.3 4.8 2.9 5.5 5.3
ALUMINUM
2024-T4
IN.-LBS.
316 S/S
IN.-LBS.
4-48 6.6 5.4 6.1 3.6 6.9 6.7 5-40 7.7 6.3 7.1 4.2 8.1 7.8 5-44 9.4 7.7 8.7 5.1 9.8 9.6 6-32 9.6 7.9 8.9 5.3 10.1 9.8 6-40 12.1 9.9 11.2 6.6 12.7 12.3 8-32 19.8 16.2 18.4 10.8 20.7 20.2
8-36 22.0 18.0 20.4 12.0 23.0 22.4 10-24 22.8 18.6 21.2 13.8 23.8 25.9 10-32 31.7 25.9 29.3 19.2 33.1 34.9
1/4-20 75.2 61.5 68.8 45.6 78.8 85.3
1/4-28 94.0 77.0 87.0 57.0 99.0 106.0 5/16-18 132 107 123 80 138 149 5/16-24 142 116 131 86 147 160
3/8-16 236 192 219 143 247 266
3/8-24 259 212 240 157 271 294 7/16-14 376 317 349 228 393 427 7/16-20 400 327 371 242 418 451
1/2-13 517 422 480 313 542 584
1/2-20 541 443 502 328 565 613 9/16-12 682 558 632 413 713 774 9/16-18 752 615 697 456 787 855
5/8-11 1110 907 1030 715 1160 1330
5/8-18 1244 1016 1154 798 1301 1482
3/4-10 1530 1249 1416 980 1582 1832
3/4-16 1490 1220 1382 958 1558 1790
7/8-9 2328 1905 2140 1495 2430 2775
7/8-14 2318 1895 2130 1490 2420 2755
1-8 3440 2815 3185 2205 3595 4130
1-14 3110 2545 2885 1995 3250 3730
MONEL
IN.-LBS.
24