16555 East Gale Avenue
City of Industry, CA 91745-1788
626/968-5666 • FAX 626/968-5716
C24
C24 LED Accent Light Installation Instructions
INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY TO PERSONS
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: Fixtures must be grounded in accordance with local codes or the
!
National Electrical Code. Portable spear or tree mounts using a cord and plug must be plugged into a
receptacle protected by a Ground Fault Circuit Interrupter (GFCI) in accordance with the National Electrical
Code. Failure to take these steps may result in serious personal injury. Lighted lamp is HOT!
AVERTISSEMENT: Les luminaires doivent être mis à la terre conformément aux codes locaux ou
!
au National Electrical Code. Lance ou arbres supports portables utilisant un cordon et la prise doivent
être branchés dans une prise protégée par un disjoncteur différentiel (GFCI) conformément au Code national
de l’électricité. Le défaut de prendre ces mesures peut entraîner des blessures graves. La lampe allumée
est CHAUD!
NOTE: All wiring must be done by a qualified electrician.
!
REMARQUE: Tout le câblage doit être fait par un électricien certifié.
!
See additional warnings and cautions on p. 3.
KEEP THIS SHEET FOR FUTURE REFERENCE.
Your KIM fixture is supplied with 1/2" NPSM male mounting threads and locknut.*
Tools Required: q Flat Blade Screwdriver q Thread Sealant q 3/32" Allen Wrench
Make certain the electrical supply is OFF before starting fixture installation.
!
Assurez-vous que l’alimentation électrique est coupée avant l’installation du luminaire.
!
Thread
Sealant
Locknut
J-Box
Top
Gasket
1. Apply thread sealant onto exposed
fixture threads to keep moisture
from entering junction box. Thread
fixture onto junction box cover or
mounting device.
*Consult Kim Landscape Lighting Collection Catalog for mounting device options.
9/30/14 EC 140930036 Status A Part No. 93054366
2. Attach fixture leads to circuit leads
observing polarity, i.e.; greento-ground, white-to-common
and black-to-voltage with wire
connectors by others.
3. Tighten locknut to ensure selected
orientation. Tighten screw under
J-Box cover, (if supplied), to
secure fixture. Attach cover.

C24 LED Accent Light Installation Instructions
Set
Screw
4. Loosen set screw and swivel
screw, but do not disengage. Hold
fixture at desired angle and tighten
Swivel
Screw
swivel screw firmly. Tighten set
screw firmly to lock angle adjustment
of fixture.
Kim Lighting • 16555 E. Gale Ave. • City of Industry, CA 91716-0080 • 626/968-5666 • FAX 626/968-5716 Page2