Installation Instructions G3
For Outdoor Fixtures 346013 & 346013F Page 1 of 3
CAUTION: FAILURE TO INSTALL THIS FIXTURE PROPERLY MAY RESULT IN SERIOUS PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE. We recommend installation by a licensed electrician.
This product must be installed in accordance with applicable installation code(s), by a person familiar with the
construction and operation of the product and the hazards involved.*
Caution: Do not exceed maximum watta
Component Parts
Note: Fixture, Post and Cover Cap each sold separately.
A J Bolts
B Fixture post
C Washers (4)
D Split washers (4)
E 5/16 nuts (4)
To Install (Figures 1 & 2)
Caution: Be sure power is off at the main breaker box prior to installation.
Site Preparation
1. Run appropriate wiring to the site of the fixture, leaving enough excess wire to
reach the top of the post, plus 12 inches.
2. Pour flat and level concrete base with wiring emerging at the center. Insert J
bolts (A) so approximately 1" of the bolts are exposed above the concrete.
Position J bolts according to the supplied template. Allow concrete to cure
before installing fixture.
e noted on fixture. Use only recommended bulbs with fixture.
F Cover Cap (sold separately)
G Fixture
H Set screw
I Rubber Strip
J Fixture Collar
Installation
Note: Post may be cut to length as desired before installation begins.
1. Position post over J bolts allowing supply wire to run up though the post and
secure using washers (C), split washers (D) and nuts (E).
2. Place optional cover cap (sold separately) (F) over post to conceal mounting
hardware.
3. Connect fixture wires to supply wires using appropriate wire connectors (not
provided), black to black, white to white and bare copper or green to bare
copper or green. If fixture is wired with twin lead lamp cord, connect smooth
side of fixture wire to black and ridged side to white.
4. Install the rubber strip (I) centered on each inside wall of the fixture collar.
5. Place fixture (G) onto post carefully tucking all wiring down into post and
making sure no wires are pinched between the post and the fixture. Secure with
set screw (H) using a 1/8” hex key wrench (not supplied).
(Figure 1)
(continued)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
14940 Rev D

Installation Instructions G3
For Outdoor Fixtures 346013 & 346013F Page 2 of 3
Use this template to position J bolts and wireway in concrete slab prior to installing outdoor post mounted lighting fixture.
(Figure 2)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
(continued)
14940 Rev D

Installation Instructions G3
For Outdoor Fixtures 346013 & 346013F Page 3 of 3
Component Parts
Note: Fixture, Post and Cover Cap each sold separately.
K Glass
L Retaining Ring (2)
M Glass Shield
N Threaded Socket
To Install
Caution: Be sure power is off at the main breaker box prior to
installation.
1. Position Glass Shield (M) over Threaded Socket (N)
2. Install 150-watt max type A light bulb and glass (K).
3. Note: The glass is mouth blown. Minor irregularities, including
4. Restore electricity to breaker.
If you need further assistance, or find that you are missing any parts, please contact the dealer from which you purchased
this product. We hope you enjoy your fixture!
* Hubbardton Forge will not be liable for injury or damage caused by improper installation, lamping or use of this fixture
(Figure 3)
and secure with the two Retaining Rings (L).
being slightly out of square, are normal. It may be necessary to
turn the glass in relation to the fixture to achieve a good fit.
(Figure 3)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
14940 Rev C