Hubbardton Forge 204710 User Manual

Installation Instructions B177
For Antasia Sconce 20-4710L, 20-4710R, 20-4710EL & 20-4710ER Page 1 of 3
CAUTION: FAILURE TO INSTALL THIS FIXTURE PROPERLY MAY RESULT IN SERIOUS PERSONAL INJURY OR DEATH AND PROPERTY DAMAGE. We recommend installation by a licensed electrician.
This product must be installed in accordance with applicable installation code(s), by a person familiar with the construction and operation of the product and the hazards involved.*
Caution: Do not exceed maximum wattage noted on fixture. Use only recommended bulbs with fixture.
Please Note: This fixture is designed to be mounted on a standard wall surface and may not be suitable for all applications. If installing in a non-wood frame application, we recommend consulting a qualified builder or electrician.
To Mount Fixture to Wall with Single Box (Figure 1)
Component Parts
A Crossbar B Threaded Stud C Barrel Knob D Fixture Assembly E Ground Screw F Cupped Washer
Caution: Be sure power is off at the main breaker box prior to installation.
1. Carefully unpack the fixture from the carton.
2. Using two machine screws (not provided), fasten
the crossbar (A) to the electric box making sure crossbar is level.
Note: A new electric box comes with screws. When replacing a fixture, retain the existing screws for use with the new fixture
3. Thread stud (B) into the appropriate hole in the
crossbar (A). Adjust the stud to proper length to ensure the fixture will fit snugly to the wall.
4. Hold the fixture assembly (D) close to the wall
and using suitable wire connectors (not provided) connect fixture wires to supply (white to white or ribbed and black to black or smooth). Ground the crossbar (A) using the green ground screw (E) and cupped washer (F) to secure a pigtail lead to the bracket. .
Caution: Make sure wire connectors are twisted on securely, and no bare wire is exposed.
5. Slide fixture assembly (D) over threaded stud (B)
and push firmly to wall, making sure that no wires are pinched between fixture back and wall. Fasten with barrel knob (C). Be sure threaded stud (B) is fully seated in the barrel knob (C).
6. See instructions following to install glass.
Hand-Forged, Vermont-Made Lighting and Accessories P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
.
(Figure 1)
(continued)
22737
Installation Instructions B177
For Antasia Sconce 20-4710L, 20-4710R, 20-4710EL & 20-4710ER Page 2 of 3
To Mount Fixture to Wall with Standard 4" Box (Figure 2)
Component Parts
A Crossbar B Threaded Stud C Barrel Knob D Fixture Assembly E Ground Screw F Cupped Washer G Wall Bracket H 8-32 x 3/8” Screw
Caution: Be sure power is off at the main breaker box prior to installation.
1. Carefully unpack the fixture from the carton.
2. Using two machine screws (not provided), fasten
the crossbar (A) to the electric box making sure crossbar is level.
Note: A new electric box comes with screws. When replacing a fixture, retain the existing screws for use with the new fixture
3. Thread stud (B) into the appropriate hole in the
crossbar (A). Adjust the stud to proper length to ensure the fixture will fit snugly to the wall.
4. Attach wall bracket (G) using 8-32 x 3/8" screw
(H). Threaded stud installed in crossbar will pass through wall bracket.
5. Hold the fixture assembly (D) close to the wall
and using suitable wire connectors, not provided, connect fixture wires to supply (white to white or ribbed and black to black or smooth). Ground the crossbar (A) using the green ground screw (E) and cupped washer (F) to secure a pigtail lead to the bracket.
Caution: Make sure wire connectors are twisted on securely, and no bare wire is exposed.
6. Slide fixture assembly (D) over threaded stud
(B) and push firmly to wall, making sure that no wires are pinched between fixture back and wall. Fasten with barrel knob (C). Be sure threaded stud (B) is fully seated in the barrel knob (C).
7. See instructions following to install glass.
.
(Figure 2)
Hand-Forged, Vermont-Made Lighting and Accessories P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
(continued)
22737
Loading...