Installation Instructions B237
Sweeping Taper Sconce 20-4526 Page 1 of 3
CAUTION: FAILURE TO INSTALL THIS FIXTURE PROPERLY MAY RESULT IN SERIOUS PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE. We recommend installation by a licensed electrician.
This product must be installed in accordance with applicable installation code(s), by a person familiar with the
construction and operation of the product and the hazards involved.*
Caution: Do not exceed maximum wattage noted on fixture. Use only recommended bulbs with fixture.
Please Note: This fixture is designed to be mounted on a standard wall surface and may not be suitable for all
applications. If installing in a non-wood frame application, we recommend consulting a qualified builder or electrician.
After installation extra hardware and accessories are possible; our kits are used on multiple products and options.
To Mount Fixture to Wall with Single Box (Figure 1)
Component Parts
A Crossbar
B Ground Screw
C Nipple
D Lock Nut
E Threaded Cap
F Fixture Assembly
Caution: Be sure power is off at the main breaker box
prior to installation.
1. Carefully unpack the fixture from the carton.
2. Using two machine screws (not provided), fasten the
crossbar (A) to the electric box making sure crossbar
is level.
Note: A new electric box comes with screws. When
replacing a fixture, retain the existing screws for use
with the new fixture
3. Thread the nipple (C) into the crossbar (A) and secure
with lock nut (D). Adjust the nipple to proper length
to ensure the fixture will fit snugly to the wall.
4. Ground the crossbar (A) by securing a pigtail lead
around ground screw (B).
5. Hold the fixture assembly (F) close to the wall and
using suitable wire connectors, not provided, connect
fixture wires and pigtail leads to supply wires (white
to white or ribbed, black to black or smooth and green
to green or bare).
Caution: Make sure wire connectors are twisted on
securely, and no bare wire is exposed.
6. Carefully tuck all wires behind the fixture, place
fixture firmly against the wall and fasten with
threaded cap (E).
7. See instructions following to install wall plate.
.
(Figure 1)
(continued)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
26943

Installation Instructions B237
Sweeping Taper Sconce 20-4526 Page 2 of 3
To Mount Fixture to Wall with Standard 4" Box (Figure 2)
Component Parts
A Crossbar
B Ground Screw
C Nipple
D Lock Nut
E Threaded Cap
F Fixture Assembly
G Wall Plate
H Ground Screw
I Cupped Washer
Caution: Be sure power is off at the main
breaker box prior to installation.
1. Carefully unpack the fixture from the
carton.
2. Using two machine screws (not provided),
fasten the crossbar (A) to the electric box
making sure crossbar is level.
Note: A new electric box comes with
screws. When replacing a fixture, retain the
existing screws for use with the new fixture
3. Thread the nipple (C) into the crossbar (A).
Adjust the nipple to proper length to ensure
the fixture will fit snugly to the wall.
4. Ground the crossbar (A) by securing a
pigtail lead around ground screw (B).
5. Orient the wall plate (G) so that the bent tab
is at the top and bent away from the wall
and slip onto nipple (C). The tab will fit into
the back of the fixture to facilitate
alignment.
6. Run a pigtail lead using ground screw (H)
and cupped washer (I).
7. Thread the pigtail lead and fixture wires through
the large diameter hole at the bottom of the wall plate (G).
8. Hold the fixture assembly (F) close to the wall and using suitable wire connectors, not provided, connect fixture
wires and pigtail leads to supply wires (white to white or ribbed, black to black or smooth and green to green or
bare).
Caution: Make sure wire connectors are twisted on securely, and no bare wire is exposed.
9. Secure nipple (C) and wall plate (G) with lock nut (D).
10. Place fixture firmly against the wall and fasten with threaded cap (E).
11. See instructions following to install glass.
.
(Figure 2)
(continued)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
26943

Installation Instructions B237
Sweeping Taper Sconce 20-4526 Page 3 of 3
To Install Glass
Component Parts
J Retaining Ring
K Glass Spacer
L Glass
M Socket
1. Remove retaining ring (J) from socket (M). Retaining ring is shipped
installed.
2. Slip glass (L) over socket (M) then place glass spacer (K) over socket (M).
3. Reinstall retaining ring (J)
4. Install light bulb. Light bulb not included
5. Restore electricity at the main breaker. If installing shade option wait to
restore electricity until after shade is installed.
If you need further assistance, or find that you are missing any parts, please contact the dealer from which you purchased
this product. We hope you enjoy your fixture!
*
Hubbardton Forge will not be liable for injury or damage caused by improper installation, lamping or use of this fixture.
(Figure 3)
(Figure 3)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
26943