Assembly & Installation Instructions A257
For Aura Pendant 13-8585 Page 1 of 3
CAUTION: FAILURE TO INSTALL THIS FIXTURE PROPERLY MAY RESULT IN SERIOUS PERSONAL
INJURY OR DEATH AND PROPERTY DAMAGE. We recommend installation by a licensed electrician.
This product must be installed in accordance with applicable installation code(s), by a person familiar with the
construction and operation of the product and the hazards involved.*
Caution: Do not exceed maximum wattage noted on fixture. Use only recommended bulbs with fixture.
To Install to Ceiling (Figures 1 thru 6)
Component Part
A Ceiling Bracket
B Lag Screw (4)
C Hex Nut
D Canopy
E Strain Relief
F Support Cable (3)
G Cable Gripper (3)
H Strain Relief Cap
Caution: Be sure power is off at the main breaker box prior to
installation.
1. Carefully unpack the fixture from the carton.
2. Put the ceiling bracket (A) and canopy (D) together, making sure
the canopy mounting holes match up with the ceiling bracket
threaded standoffs. Orient them to achieve desired wire location.
Note: Canopy and ceiling bracket only install one direction which
determines where the wire entry location through the canopy
will be.
3. Using the four lag screws (B) attach ceiling bracket (A) to a
structural member in the ceiling, centering the
crossbar over the outlet box. We've supplied lag
screws with your fixture; however, different
materials and/or construction methods may
require different fasteners. If in doubt, contact a
qualified electrician. Do not
directly to outlet box.
4. Install strain relief (E) into canopy (D). Thread
hex nut (C) onto strain relief and tighten
(Figure 2). Do not over-tighten.
5. Raise fixture and push support cable (F) next to
the strain relief (E) through cable gripper (G).
Slip canopy (D) onto the cable oriented so the
strain reliefs are above each other.
6. Slip the other two support cables (F) through the
canopy (D) and into the cable grippers (G) until
desired fixture height is accomplished and level.
7. Slip supply wire (I) through the strain relief cap
(H) and through the strain relief (E).
I Supply wire
J Flat Head Screws (2)
K Threaded Standoffs (2)
L Cupped Washer
M Ground Screw
N Canopy Nipple
O Canopy Cover
P Lock Up
(Figure 1)
(Figure 2)
attach crossbar
(Figure 3)
(continued)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
24787
Assembly & Installation Instructions A257
For Aura Pendant 13-8585 Page 2 of 3
8. Pull supply wire (I) out through the back of the canopy (D).
9. Raise the canopy (D) to the ceiling and attach to ceiling
bracket (A) with two flat head screws (J) threaded into two
threaded standoffs (K) (Figure 4).
10. Pull supply wire (I) through canopy (D) out through the center
hole in canopy (D).
11. Thread strain relief cap (H) onto strain relief (E) until snug.
12. Cut excess supply wire (I) allowing enough left (approx. 6”) to
make connections in the electrical box. Strip outside jacket
being careful not to cut through shielding of the two inner
conductors.
13. Run a pigtail lead from the ceiling bracket (A) using cupped
washer (L) and ground screw (M) to the junction box. Using
suitable wire connectors (not provided) connect unshielded
wire from supply wire (I) to all ground wires (bare copper or
green shielded) (Figure 5).
14. Using suitable wire connectors (not provided) connect
fixture wires to supply (wire with white tracer to white and
wire with no tracer to black).
connectors are twisted on securely, and no bare wire is exposed.
15. Thread canopy nipple (N) in to threaded hole directly in
center of ceiling bracket (A).
16. Install canopy cover (O) on canopy nipple (N).
17. Thread lock up (P) on to canopy nipple (N). Tighten against
canopy cover (O) until snug.
Caution: Make sure wire
18. Refer to instructions following to install bulb and glass.
(Figure 4)
(Figure 5)
(Figure 6)
Hand-Forged, Vermont-Made Lighting and Accessories
P.O. Box 827, 154 Route 30 South, Castleton, Vermont 05735
(continued)
24787