Huba 691 Service Manual

691
Pressure transmitter
Relative –1 to 600 bar Absolute 0 to 16 bar
EDITION 12/2004
Huba Control
FOR FINE PRESSURE AND FLOW MEASUREMENT
HUBA-REGISTERED TRADE MARK
The pressure transmitter of type series 691 with unique and for the last 10 years used in millions of applications ceramic technology, features calibrated and amplified sensor signals which are available as standardized voltage or current out­puts.
Various application-specific pressure and electri­cal connections can be provided.
Legend to cross-section drawing
1 Connection fitting 2 Seals 3 Ceramic element 4 Cover
The distinct advantages
Very low temperature sensitivity
High resistance to extreme temperatures
No mechanical aging
No mechanical creepage
Individual applications due to modular
system
Pressure ranges
Absolute pressure, Relative pressure (Gauge) (dif­ferential measurement of pressure relative to am­bient pressure) See order code selection table
Overload
2 x Measuring range (fs)
Rupture pressure
3 x Measuring range (fs)
Accuracy
Total of linearity, hysteresis and repeatability < +/- 0.3% fs
Zero point residual voltage < 50 mV Zero point residual current at version 0 – 20 mA < 150 ␮A
Materials of housing in contact with the medium
Ceramic / Inox 1.4305 (Ceramic / PVDF on request) Sealing material: optionally FPM, EPDM, NBR, silicone according to order code selection table
Application temperature
Medium and ambient temperature – 15 …+ 80 °C
Medium and ambient temperature – 40 °C only with CR seal and on request
Temperature influences
TC zero point < +/- 0.03% fs/K TC sensitivity < +/- 0.015% fs/K typ.
Load cycle
< 50 Hz
Dynamic response
Suitable for static and dynamic measurements. Response time: < 5 ms
Pressure connections
Inside thread G 1/4 Outside thread, connection fitting sealed at front or at back (option) 1/4-18 NPT
Weight
Inside thread G 1/4 200 g Outside thread G 1/8 / 7/16-20 UNF 212 g G 1/4 / 1/4-18 NPT 245 g G 1/2 / 1/2-14 NPT 280 g
Installation arrangement
Unrestricted
Signal Power supply
0 – 10 V 18 – 33 VDC
24 VAC +/- 15% 3 wire cable
4 – 20 mA 11 – 33 VDC
2-wire cable
0 – 5 Volt 11 – 33 VDC
24 VAC +/- 15% 3-wire cable
Short circuit-proof and protected against polari­ty reversal. Each connection against other with max. +/- supply voltage. Frequency output on request. Switching output, see type 615.
Load
0 – 10 V > 10 k Ohm 4 – 20 mA < [Ohm]
Load
With max. signal output 0 – 10 V < 5 mA 4 – 20 mA < 20 mA
Electrical connections / Protection standard
Cable 1.5 meters, IP 67 or IP 65 Round plug connector DIN 41524, 3-pole, IP 65 Connector DIN EN 175301-803-A, IP 65
Electromagnetic compatibility
EMC-Behavior see on the back. «Germanischer Lloyd» certification on request.
Calibration by customer
Adjustable versions (zero point/slope approx. +/- 10%) only with IP versions.
supply voltage – 11 V
0.02 A
Loading...
+ 2 hidden pages