Huawei UPS5000-200 kVA User Manual

Part Number: 31507912
User Manual
Issue
Draft A
Date
2016-12-09
HUAWEI TECHNOLOGIES CO., LTD.
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
Copyright © Huawei Technologies Co., Ltd. 2016. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China
Website:
http://e.huawei.com
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual

About This Document

Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii
Purpose
Symbol
Description
Indicates an imminently hazardous situation which, if not avoided, will result in serious injury or death.
Indicates a potentially hazardous situation which, if not avoided, could result in serious injury or death.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.
NOTICE is used to address practices not related to personal
When the UPS is installed against a wall, install the top air-flow cabinet to ensure heat dissipation. This document describes how to install the top air-flow cabinet.
Intended Audience
This document is intended for:
Sales engineers
Technical support engineers
System engineers
Hardware installation engineers
Commissioning engineers
Data configuration engineers
Maintenance engineers
About This Document
Symbol Conventions
The symbols that may be found in this document are defined as follows.
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
About This Document
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii
Symbol
Description
injury.
Calls attention to important information, best practices and tips. NOTE is used to address information not related to personal
injury, equipment damage, and environment deterioration.
Change History
Changes between document issues are cumulative. The latest document issue contains all updates made in previous issues.
Issue Draft A (2016-12-09)
This issue is used for first office application (FOA).
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual

Contents

Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iv
Contents
About This Document .................................................................................................................... ii
1 Safety Precautions ......................................................................................................................... 1
2 Product Overview ......................................................................................................................... 2
2.1 Model Description ........................................................................................................................................................ 2
2.2 Product Structure .......................................................................................................................................................... 4
3 Product Installation ...................................................................................................................... 7
3.1 Unpacking and Checking .............................................................................................................................................. 7
3.2 Installation Tools ........................................................................................................................................................... 7
3.3 Installation and Securing .............................................................................................................................................. 8
3.3.1 Securing the Top Air-flow Cabinet Used for a Single-Cabinet UPS .......................................................................... 9
3.3.2 Securing the Top Air-flow Cabinets Used for a Multi-Cabinet UPS ....................................................................... 18
3.4 Cable Connection ........................................................................................................................................................ 22
3.4.1 Connecting Cables to the Top Air-flow Cabinet Used for a Single-Cabinet UPS.................................................... 22
3.4.2 Connecting Cables to the Top Air-flow Cabinets Used for a Multi-Cabinet UPS ................................................... 27
4 User Settings ................................................................................................................................ 34
5 Replacing a Fan............................................................................................................................ 36
A Acronyms and Abbreviations .................................................................................................. 38
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual

1 Safety Precautions

Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
1 Safety Precautions
Carefully read this document before installing the top air-flow cabinet. Only qualified and trained personnel are allowed to install, operate, and maintain the top air-flow cabinet.
Before installing the top air-flow cabinet, get tools insulated and remove conductive objects such as watches and rings.
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual

2 Product Overview

Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2

2.1 Model Description

No.
Description
1
Accessory
2
Top air-flow cabinet
3  00: used for 600 mm wide cabinets, with a fan transit unit
01: used for 600 mm wide cabinets
02: used for 800 mm wide cabinets
Figure 2-1 Top air-flow cabinet model number
2 Product Overview
Table 2-1 Top air-flow cabinet model number description
Single-cabinet UPS: The UPS has only one cabinet. The following figure shows the installation position for the top air-flow cabinet.
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
2 Product Overview
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
Figure 2-2 Installation position of the top air-flow cabinet for a single-cabinet UPS
Dual-cabinet UPS: The UPS has one power cabinet and one bypass cabinet. The following figure shows the installation position for the top air-flow cabinet.
Figure 2-3 Installation positions of the top air-flow cabinets for a dual-cabinet UPS
Four-cabinet UPS: The UPS has two power cabinets and two bypass cabinets. The following figure shows the installation position for the top air-flow cabinet.
Figure 2-4 Installation positions of the top air-flow cabinets for a four-cabinet UPS
In this document, multi-cabinet UPSs refer to the dual-cabinet UPS and four-cabinet UPS unless otherwise specified.
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
2 Product Overview
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4

2.2 Product Structure

(1) Fan transit unit
(2) Fan transit unit protective cover
(3) Fan interconnection terminal cover
(4) Cable trough
(5) Fan assemblies
(6) Anchor bolts
Only one of the top air-flow cabinets of the multi-cabinet UPS has the fan transit unit and power switch.
Figure 2-5 Top air-flow cabinet structure
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
2 Product Overview
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5
Figure 2-6 Side view of the top air-flow cabinet (unit: mm)
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
2 Product Overview
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6
Figure 2-7 Cable trough of the top air-flow cabinet
(1) Fan power ports (14-pin)
(2) 24-pin terminal port
(3) Switch protective cover
(4) Power switch
Figure 2-8 Fan power port
Figure 2-9 24-pin terminal port
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual

3 Product Installation

Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
3 Product Installation
Tool
Picture
Used To
Step ladder
Support work at heights.
Multimeter
Check electrical connections and measure electrical parameters. Insulated Phillips screwdriver
Connect cables and tighten screws.
Level
Level cabinets.

3.1 Unpacking and Checking

After the top air-flow cabinet is delivered onsite, unpack the case and check as follows:
Visually inspect the appearance of the top air-flow cabinet for shipping damage. If any damage is found, notify the carrier immediately.
Check that the fittings comply with the packing list. If some fittings are missing or do not comply with the packing list, record the information and contact your local Huawei office immediately.

3.2 Installation Tools

Table 3-1 lists the installation tools.
Table 3-1 Tools
UPS5000-(200 kVA-800 kVA) Top Air-flow Cabinet User Manual
3 Product Installation
Issue Draft A (2016-12-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
Tool
Picture
Used To
Insulated torque wrench
Tighten bolts.
Diagonal pliers
Cut cable ties.
Insulation tape
Provide electrical insulation.
Brush
Clean panels and shells.
Protective gloves
Protect hands.
ESD gloves
Protect devices from ESD.
Insulation gloves
Provide insulation.
Insulation protective shoes
Protect operators.
Cable tie
Bind cables.

3.3 Installation and Securing

Loading...
+ 30 hidden pages