Huawei UPS2000-G-1 kVA, UPS2000-G-2 kVA, UPS2000-G-3 kVA Quick Installation Manual

Quick Installation Guide
Issue
03
Date
2015-10-12
HUAWEI TECHNOLOGIES CO., LTD.
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
i
Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China
Website:
http://e.huawei.com
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
About This Document
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
ii
About This Document
Purpose
This document describes the UPS2000-G-(1 kVA-3 kVA) battery pack in terms of its appearance, features and specifications, and installation and connections. Unless otherwise specified, UPS refers to all the models discussed in this document.
Intended Audience
This document is intended for:
Sales engineers
Technical support engineers
System engineers
Hardware installation engineers
Commissioning engineers
Data configuration engineers
Maintenance engineers
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results.
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
About This Document
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iii
Symbol
Description
NOTICE is used to address practices not related to personal injury.
Calls attention to important information, best practices and tips.
NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.
Change History
Changes between document issues are cumulative. The latest document issue contains all the changes made in previous issues.
Issue 03 (2015-10-12)
Added the 2 kVA UPS battery pack.
Issue 02 (2015-08-10)
Updated the dimensions of battery pack.
Issue 01 (2015-06-25)
This is the first release.
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
Contents
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
iv
Contents
About This Document .................................................................................................................... ii
1 Precautions ..................................................................................................................................... 1
2 Appearance and Feature .............................................................................................................. 2
2.1 Exterior ......................................................................................................................................................................... 2
2.2 Features ......................................................................................................................................................................... 3
2.2.1 Battery Pack for 1 kVA UPS ...................................................................................................................................... 3
2.2.2 Battery Pack for 2 kVA UPS ...................................................................................................................................... 4
2.2.3 Battery Pack for 3 kVA UPS ...................................................................................................................................... 5
3 Installing the Battery Pack .......................................................................................................... 7
3.1 Unpacking and Checking .............................................................................................................................................. 7
3.2 Preparations .................................................................................................................................................................. 7
3.3 Installation Procedure ................................................................................................................................................... 8
3.3.1 Rack-Mounted Battery Pack ...................................................................................................................................... 8
3.3.2 Tower-mounting a Battery Pack................................................................................................................................. 9
4 Connecting a Battery Pack and a UPS ..................................................................................... 13
4.1 Connecting a Battery Pack and a 1 kVA UPS ............................................................................................................. 13
4.2 Connecting a Battery Pack and a 2 kVA UPS ............................................................................................................. 15
4.3 Connecting a Battery Pack and a 3 kVA UPS ............................................................................................................. 17
A Acronyms and Abbreviations .................................................................................................. 20
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
1 Precautions
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1
1 Precautions
1. Only the professional technical personnel designated by Huawei are allowed to install
and operate the battery pack.
2. Read this document closely before operating the battery pack. Keep this document for
future use.
3. When operating Huawei equipment, you must follow the local laws and regulations.
4. You can modify default parameters only after being approved by Huawei technical
support.
5. To prevent electric shocks, get the tool insulated and wear insulation gloves when
connecting cables.
6. To prevent personal injury, wear protective shoes when moving the battery pack.
7. In case of fire, use a dry powder extinguisher to put out the fire. Using a fluid fire
extinguisher may cause electric shocks.
8. Do not touch uninsulated battery terminals. Otherwise, electric shocks may occur.
9. Using incorrect battery models may cause explosion. Dispose of used batteries by
following instructions specified.
10. Cut off power supply and remove all the metal objects such as the watch, bracelet, or
ring before maintenance.
11. Do not transport the device by holding the mounting brackets, front panel, or protective
cover. When moving a heavy device, follow the product movement regulations, as shown in Figure 1-1.
Figure 1-1 Product movement regulations
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2
2 Appearance and Feature
2.1 Exterior
Rack-mounted battery packs can either be rack-mounted or tower-mounted. As shown in
Figure 2-1 and Figure 2-2.
Figure 2-1 Rack-mounted battery pack
Figure 2-2 Tower-mounted battery pack
The standard battery pack for 1 kVA UPS with long backup time is ESS-36V12-9*2AHBPVBB01. The standard battery pack for 2 kVA UPS with long backup time is ESS-72V12-9AHBPVBB01. The standard battery pack for 3 kVA UPS with long backup time is ESS-96V12-9AHBPVBB02. The appearance for 1 kVA UPS, 2 kVA UPS, and 3 kVA UPS are the same. The figures below based on the 3 kVA UPS, as shown in Figure 2-3.
UPS2000-G-(1 kVA-3 kVA) Battery Pack Quick Installation Guide
2 Appearance and Feature
Issue 03 (2015-10-12)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
Figure 2-3 Standard battery pack (ESS-96V12-9AHBPVBB02) for 3 kVA UPS and its external ports
(1) DC port 1
(2) DC port 2
(3) Protection switch
Table 2-1 describes the input and output ports on the battery pack.
Table 2-1 Input and output ports on the battery pack
No.
Port
Port Type
1
DC port 1
SA50 x 2
2
DC port 2
SA50 x 2
2.2 Features
2.2.1 Battery Pack for 1 kVA UPS
Model
ESS-36V12-9*2AHBPVBB01
Interior
Two group of battery strings are embedded, each group with three 9 Ah/12 V DC batteries. The output voltage of battery pack is 36 V DC.
Basic Features
Color: black
Panel: plastic
Backplane: grey (SECC/SGCC)