Huawei 7802, 7803, 7806, 7810, Quidway S7800 Specifications

...
Quidway
®
S7800 Series Carrier-class Switches Product Specification
Copyright ©2007 Huawei Technologies Co., Ltd. All Rights Reserved.
http://www.huawei.com/products/datacomm/
1
Quidway® S7800 Series Carrier-class Switches
Product Specification
Product Specifications
Attribute 7802 7803 7806/7806V 7810 Switching Capacity (bps)
192G 368G 656G 560G
Backboard Bandwidth
400G 1.3T 1.3T 2.15T
Packet forwarding speed(pps)
142.85M 273.79M 488.06M 416.64M
Slot
4 5 8 12
Service Slots
2 3 6 10
L2 Features
4K VLANSelective QinQ, Can be expanded up to 4K×4K VLAN Super VLAN Support 802.1P Priority Support 128K MAC Table STP/RSTP/MSTP GVRP Support port bundlingLACP, cross-board bundling port mirroring Broadcast storm suppression Ethernet_II/Ethernet_SNAP/IEEE 802.2/IEEE 802.3 compatibility MDI/MDI-X negotiation
L3 Features
ARP Proxy RIPOSPFIS-ISBGP4 128K longest-match routing table Routing Load Balance Distributed policy routing VRRP DHCP RELAYDHCP SERVER
Multicast
PIM-DM PIM-SM MSDP/MBGP GMRP IGMP IGMP Snooping IGMP Filter
Quidway
®
S7800 Series Carrier-class Switches Product Specification
Copyright ©2007 Huawei Technologies Co., Ltd. All Rights Reserved.
http://www.huawei.com/products/datacomm/
2
Attribute 7802 7803 7806/7806V 7810
IGMP Fast Leave
VPN
MPLS L3 VPN VLL&VPLS PE/P
QoS
traffic classification and filtration based on IP five-compages, VLAN , physical port and protocol number Bandwidth limiting, with the minimum granularity of 64 kbps Each port supports eight priority queues and three drop priority queues
Support SP/WRR/SP+WRR/CBWFQ queue scheduling Support traffic shaping for ports and queues congestion avoidance and drop policies
802.1P, DSCP/TOS priority and re-mark capability Support time-based traffic classification and QoS control capability
Security
Hierarchical management and password protection of users Prevent unauthorized access to the network by binding of MAC,IP and port IEEE 802.1X authentication Illegal frame filtering Port isolation Deep service detection SNMPv1/v2c/v3 NMS SSH
Reliability
MTBF > 14.66 years MTTR < 0.5 hour Dual main control boards 1+1 power redundancy Modules hot-swappable
System Architecture
Integrated chassis that can be installed in a 19-inch rack
Dimensions (W x H x D)
436x175x420 436x441.7x420
436x575.05x420 436x930.6x420
436x708.4x420
Weight (chassis only)
<15KG <25KG
<35KG <45KG
<45KG
Environment Requirements
Operation temperature:0 to 45 Operating relative humidity:10%~95%
Power Supply
650W S7802
1400WS7803/S7806/7810
Input Voltage
DC:48V to 60V AC:100V to 240V