Huawei CR-MPUB, CR-MPUE Specifications

Quidway® NetEngine 80 Core Router Main Processing Units
Copyright ©2007 Huawei Technologies Co., Ltd. All Rights Reserved.
http://www.huawei.com/products/datacomm/
1
Quidway® NetEngine 80 Core Router
Main Processing Units
The Main Processing Unit (MPU) is the core of the Quidway® NetEngine 80 core router (abbreviated to NE80).
The NE80 has 20 slots, of which two are for MPUs. The MPU is hot-pluggable. One or two MPUs are required for each NE80. It is recommended that two MPUs be configured to implement redundancy backup and improve the system reliability. When the active MPU runs normally, the standby MPU backs up status information in real time, such as configuration dat a, slot st atus, board status, interface status, power status, fan status and protocol status.
CR-MPUB
When a severe fault occurs to the active MPU or the active MPU is manually reset, the system will switch over to the standby MPU for running (supporting automatic switchover and manual switchover by commands), generate alarms, log it and notify the network management system(NMS). Switchover reason and process are recorded into the system diagnosis information database for analysis.
The MPU implements global functions of the whole system, such as routing processing, resource management, status monitoring and network management(NM) agent.
z Process routing protocols, generate the forwarding table and deliver it to line cards. z As an agent for user operations, manage the system, monitor system performance and report
equipment running status to users according to users' operation instructions.
z Monitor and maintain running states of LPUs. z Monitor and maintain running states of switching networks and clocks. z Monitor running states of the fan system and power system.
Quidway® NetEngine 80 Core Router Main Processing Units
Copyright ©2007 Huawei Technologies Co., Ltd. All Rights Reserved.
http://www.huawei.com/products/datacomm/
2
Specifications
Currently, the NE80 supports two types of MPUs: CR-MPUB and CR-MPUE. The difference lies in their memory capacity. The memory capacity of the CR-MPUB is 512 MB, while that of the CR-MPUE is 1 GB.
Both the CR-MPUB and the CR-MPUE have three external interfaces: CONSOLE port (COM port), AUX port (auxiliary COM port) and 10/100BASE-TX Ethernet port.
Module
name
Interface name
Interface
type
Description
ETH0 port RJ45
Used to connect the NM workstation; maximum transmission distance: 100 m; 10/100M adaptive; with LINK and ACT indicators.
CONSOLE port RJ45
RS-232 level; used to connect the console for on-site configuration, maintenance, management and upgrade of the system.
CR-MPUB
AUX port RJ45
RS-232 level; used to connect with Modem for remote configuration, maintenance and management through dialing.
ETH0 port RJ45
Used to connect the NM workstation;10/100M adaptive; maximum transmission distance: 100 m; with LINK and ACT indicators.
CONSOLE port RJ45
RS-232 level; used to connect the console for on-site configuration, maintenance, management and upgrade of the system.
CR-MPUE
AUX port
RJ45
RS-232 level; used to connect with Modem for remote configuration, maintenance and management through dialing.