Please take care of the sensor of the
instrument, which is fragile. Any person
tending to use, maintain or repair the product
shall carefully read this Operation Manual. The
instrument may achieve the designed
performance only when it is operated in strict
compliance with the manufacturer’s
instructions. Please observe the following
suggestions during maintenance and use of the
instrument, so as to extend its service life.
1. Do not drop, knock or violently shake the
instrument;otherwise the detector may be
damaged.
2. In case the instrument is left idle for a long
time, please take out the battery.
3. Please keep the instrument dry during
storage or use, for humidity may cause damage
to it.
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
1
4. If the instrument fails to work normally,
please sent to designated authorized service.
The final power of interpretation owe to our
company.
The Company reserves the right to upgrade the
product or modify this Manual without
notification to the user.
Warning
For safety reasons, the instrument must be
operated serviced by qualified persons
only.Please read and understand the Manual
completely before operating or servicing.
To avoid flames caused by any existing
flammable gas, please disconnect the power
before repairing the instrument.
Take care when replacing the battery, so as
to avoid short circuit between the positive and
negative poles of the battery.
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
2
The instrument adopts non-plug sensor. In
case of any malfunction, please contact our
specialists.
To replace any original part of the
instrument with part provided by other
manufacturers other than the Company may
weaken the safety of the product. Any
unauthorized modification or maintenance may
result in damage to the instrument.
Power: please use AAA battery.
Electrostatic hazards: the instrument may
be wiped clean only with a damp cloth.
Long-term storage: stable operation of the
instrument is based on proper use and
maintenance of it. If the instrument is to be
kept aside for a long time, please turn it off,
and take out the battery and place it where it is
dry.
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
3
Notes and suggestions to use and
operation
The instrument provides three single alarming
modes, i.e. sound, flash and vibration, and
three combined alarming modes, i.e. sound +
flash, sound + vibration, and flash + vibration.
When the battery is low, please turn off the
combined mode of sound + vibration (for this
mode consumes larger power and thus may
result in failure of the instrument) and replace
the power supply in time.
6. Explanation of other prompts ................... 26
6.1. 1 Prompt for low battery ....................... 26
6.2. Prompt for Err1 and solution ................ 27
7. Maintenance bond .................................... 28
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
6
1. Operation panel
Front View
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
7
Back View
The operation panel of the instrument
consists of LCD display, Alarm indicating lamp,
www.huatecgroup.com export@huatecgroup.com
HUATEC Radiometer dosimeter FJ-6600
8
Icon
Indication
Sound
Vibration
Light
Pulse indicating lamp,Function key
"MODE/POWER" and Function
key"SET/VIEW". The LCD display may show
the current time, mode, dose rate, accumulated
dose value and battery power.
1.1. LCD display (Figure 1)
Figure 1
1.2. User interface Icons
www.huatecgroup.com export@huatecgroup.com