HTW INNOVA HTWS026INNR32-EXT, INNOVA HTWS035INNR32-EXT Owners And Installation Manual

OWNER’S AND
INSTALLATION MANUAL
OUTDOOR UNIT SPLIT
ENGLISH
INNOVA
HTWS026INNR32-EXT | HTWS035INNR32-EXT
Thanks for choosing our product.
Please, read carefully this manual
before using the product.
Content
Operation Notices
Precautions ........................................................................................................ 1
Parts name .......................................................................................................... 6
Malfunction
Malfunction analysis .......................................................................................... 7
Installation Notice
Safety operation of ammable refrigerant ....................................................... 8
Installation prepare .......................................................................................... 10
Installation
Installation of outdoor unit.............................................................................. 14
Check after installation ................................................................................... 17
Test operation ................................................................................................... 17
Attachment
Conguration of connection pipe................................................................... 18
Pipe expanding method................................................................................... 19
If it needs to install, move or maintain the air conditioner, please contact dealer or local service
center to conduct it at rst. Air conditioner must be installed, moved or maintained by appointed
unit. Otherwise, it may cause serious damage or personal injury or death.
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
R32:675

Precautions

Please read this operating manual carefully before operating the unit.
Appliance lled with ammable gas R32.
Before use the appliance, read the owner's manual rst.
Befoer install the appliance,read the installation manual rst.
Befoer repair the appliance ,read the service manual rst.
The gures in this manual may be different with the material objects, please refer to the
material objects for reference.
The Refrigerant
To realize the function of the air conditioner unit, a special refrigerant circulates in the system.
The used refrigerant is the uoride R32, which is specially cleaned. The refrigerant is ammable and inodorous. Furthermore, it can leads to explosion under certain condition. But the ammability of the refrigerant is very low. It can be ignited only by re.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere. The inuence upon the greenhouse effect is also lower. R32 has got very
good thermodynamic features which lead to a really high energy efficiency. The units
therefore need a less lling.
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture. Should repair be necessary, contact your nearest authorized Service Center.
Any repairs carried out by unqualied personnel may be dangerous.
The appliance shall be stored in a room without continuously operating ignition sources.
(For example: open ames, an operating gas appliance or an operating electric heater.)
Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a oor area larger than
2
“X”m
(see table 1). (only applies to appliances that are not xed appliances)
Appliance lled with ammable gas R32. For repairs,strictly follow manufacturer's
instructions only. Be aware that refrigerants not contain odour.
Read specialist’s manual.
1
Precautions
WARNING
Operation and Maintenance
This appliance can be used by children aged of 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause re hazard. Do disconnect power supply when cleaning air conditioner.
Otherwise, it may cause electric shock. If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid electric
shock.
Do not spray water on indoor unit. It may cause electric shock
or malfunction.
After removing the lter, do not touch ns to avoid injury.
Do not use re or hair dryer to dry the lter to avoid deformation or re hazard.
Maintenance must be performed by qualied professionals. Otherwise, it may cause personal injury or damage.
Do not repair air conditioner by yourself. It may cause electric shock or damage. Please contact dealer when you need to
repair air conditioner.
Do not extend ngers or objects into air inlet or air outlet. It may cause personal injury or damage.
2
Precautions
Do not block air outlet or air inlet. It may cause malfunction.
Do not spill water on the remote controller, otherwise the remote controller may be broken.
When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualied professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or re hazard.
When turning on or turning off the unit by emergency operation switch, please press this switch with an insulating object other
than metal.
Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage or personal injury.
WARNING
Attachment
Installation must be performed by qualied professionals. Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing the
unit.
According to the local safety regulations, use qualied power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be connected in xed wiring.
Air Conditioner should be properly grounded. Incorrect grounding may cause electric shock.
3
Precautions
Including an circuit break with suitable capacity, please note the following table.Air switch should be included magnet buckle and heating buckle function, it can protect the circuit-short and overload.
Don't use unqualied power cord.
Make sure the power supply matches with the requirement of air conditioner.Unstable power supply or incorrect wiring or malfunction. Please install proper power supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and grounding wire of power socket.
Be sure to cut off the power supply before proceeding any work
related to electricity and safety.
Do not put through the power before nishing installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
WARNING
The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only.
The air conditioner is the rst class electric appliance. It must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations.
4
Precautions
WARNING
The appliance must be positioned so that the plug is accessible.
All wires of indoor unit and outdoor unit should be connected by a professional.
If the length of power connection wire is insufcient, please contact the supplier for a new one. Avoid extending the wire by
yourself.
For the air conditioner with plug, the plug should be reachable after nishing installation.
For the air conditioner without plug, an circuit break must be
installed in the line.
If you need to relocate the air conditioner to another place, only the qualied person can perform the work. Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the fence
for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Indoor side DB/WB(°C) Outdoor side DB/WB(°C)
Maximum cooling 32/23 43/26
Maximum heating 27/- 24/18
NOTE:
The operating temperature range (outdoor temperature) for cooling is 18℃~43℃; Heating
temperature range for the model without electric heating belt for chassis is -15℃ ~ 24℃; Heating temperature range for the model with electric heating belt for chassis is
-20℃~24℃.
5
Loading...
+ 15 hidden pages