California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects, or
other reproductive harm.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
This manual must only be used by a qualified heating installer/service technician. Read all instructions in this manual before installing.
Perform steps in the order given. Failure to comply could result in substantial property damage, severe personal injury, or death.
Residential Electric
Water Heater
USE AND CARE MANUAL
INSTALLATION
START-UP
MAINTENANCE
PARTS
WARRANTY
Everlast Residential Models
EVR 040 / 050
NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors
in literature.
120 Braley Rd. P.O. Box 429 East Freetown, MA 02717-0429 www.htproducts.com
LP-473 REV. 6.13.13
Page 2
2
The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk
levels, or to important product information.
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property
damage.
NOTICE
NOTICE is used to address practices not related to personal injury.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions to reduce the risk of fire, electric shock, or injury to persons should be
followed, including:
1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.
2. This water heater must be grounded. Connect only to a properly grounded outlet. See Part 4 – Heater Wiring, this manual, for
grounding details.
3. Install or locate this water heater only in accordance with the provided installation instructions.
4. Use this water heater only for its intended use as described in this manual.
5. Do not use an extension cord set with this water heater. If no receptacle is available adjacent to the water heater, contact a qualified
electrician to have one properly installed.
6. As with any appliance, close supervision is necessary when used by children.
7. Do not operate this water heater if it has a damaged cord or plug, if it is not working properly, or if it has been damaged or dropped.
8. This water heater should be serviced only by qualified service personnel. Contact the water heater installer or a qualified service
agency for examination, repair, or adjustment.
SAVE THESE INSTRUCTIONS
FOREWORD
This manual is intended to be used in conjunction with other literature provided with the electric water heater. This includes all related
control information. It is important that this manual, all other documents included with this system, and additional publications be
reviewed in their entirety before beginning any work.
Installation should be made in accordance with the regulations of the Authority Having Jurisdiction, local code authorities, and utility
companies which pertain to this type of water heating equipment.
Authority Having Jurisdiction (AHJ) – The Authority Having Jurisdiction may be a federal, state, local government, or individual such
as a fire chief, fire marshal, chief of a fire prevention bureau, labor department or health department, building official or electrical
inspector, or others having statutory authority. In some circumstances, the property owner or his/her agent assumes the role, and at
government installations, the commanding officer or departmental official may be the AHJ.
NOTE: HTP, Inc. reserves the right to modify product technical specifications and components without prior notice.
Page 3
This manual must only be used by a qualified heating installer/service technician. Read all instructions in this manual before installing.
Perform steps in the order given. Failure to comply could result in substantial property damage, severe personal injury, or death.
FOR THE INSTALLER
This water heater must be installed by qualified and licensed personnel. The installer should be guided by the instructions furnished
with the water heater, and with local codes and utility company requirements.
INSTALLATIONS MUST COMPLY WITH:
Local, state, provincial, and national codes, laws, regulations and ordinances.
The latest version of the National Electrical Code, NFPA No. 70.
TABLE OF CONTENTS
PART 1 – GENERAL SAFETY INFORMATION .......................................................................................................................... 4
A. PRECAUTIONS ................................................................................................................................................................................................ 4
B. WHEN SERVICING THE WATER HEATING SYSTEM .................................................................................................................................... 4
C. HEATER WATER ............................................................................................................................................................................................. 4
D. INSTALLATIONS IN THE STATE OF CALIFORNIA ......................................................................................................................................... 4
E. WATER CHEMISTRY ....................................................................................................................................................................................... 5
PART 2 – PREPARE THE WATER HEATER ............................................................................................................................. 5
A. WHAT’S IN THE BOX ....................................................................................................................................................................................... 5
B. SPECIFICATIONS AND PERFORMANCE RATINGS ....................................................................................................................................... 6
C. LOCATING THE WATER HEATER .................................................................................................................................................................. 6
PART 3 – HEATER PIPING ......................................................................................................................................................... 8
A. PLUMBING ....................................................................................................................................................................................................... 8
B. THERMAL EXPANSION ................................................................................................................................................................................... 8
C. CONDENSATION ............................................................................................................................................................................................. 8
D. INSULATION BLANKETS................................................................................................................................................................................. 8
E. TEMPERATURE AND PRESSURE RELIEF VALVE ........................................................................................................................................ 9
F. FILLING THE HEATER ..................................................................................................................................................................................... 9
G. SCALDING ..................................................................................................................................................................................................... 10
H. INSTALLATION DIAGRAMS .......................................................................................................................................................................... 11
PART 4 – HEATER WIRING ...................................................................................................................................................... 11
PART 5 – INSTALLATION CHECKLIST ................................................................................................................................... 12
PART 6 – OPERATING THE HEATER...................................................................................................................................... 13
A. COMBINATION THERMOSTAT AND HIGH LIMIT CONTROL (ECO) ............................................................................................................ 13
B. THERMOSTAT ADJUSTMENT AND ECO RESET ......................................................................................................................................... 13
C. HEATING ELEMENT REPLACEMENT PROCEDURE ................................................................................................................................... 14
PART 7 – MAINTENANCE ........................................................................................................................................................ 15
PART 8 – TROUBLESHOOTING .............................................................................................................................................. 16
HTP CUSTOMER INSTALLATION RECORD FORM ............................................................................................................................................. 20
INSTALLER – Read all instructions in this manual before installing. Perform steps in the order given.
USER – This manual is for use only by a qualified heating installer/service technician. Have this water heater serviced/inspected by a qualified service technician annually.
FAILURE TO ADHERE TO THE GUIDELINES ON THIS PAGE AND HAVE THIS WATER HEATER SERVICED/INSPECTED
ANNUALLY CAN RESULT IN SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
NOTE: If the heater is exposed to the following, do not operate until all corrective steps have been made by a qualified serviceman:
FIRE
DAMAGE
WATER
Any claims for damage or shortage in shipment must be filed immediately against the transportation company by the consignee.
DO NOT USE THIS WATER HEATER IF ANY PART HAS BEEN SUBMERGED IN WATER. Immediately call a qualified service
technician. The water heater MUST BE replaced if it has been submerged. Attempting to operate a water heater that has been
submerged could create numerous harmful conditions, such as a potential gas leakage causing a fire and/or explosion, or the release
of mold, bacteria, or other harmful particulates into the air. Operating a previously submerged water heater could result in property
damage, severe personal injury, or death.
NOTE: Water heater damage due to flood or submersion is considered an Act of God, and IS NOT covered under product warranty.
Be sure to disconnect electrical power before performing service. Failure to do so could result in an electrical shock, property damage,
serious personal injury, or death.
This water heater is not designed or intended for use in space heating applications. Failure of a water heater due to unapproved use IS
NOT covered by the warranty.
California Law requires that residential water heaters must be braced, anchored, or strapped to resist falling or horizontal displacement
due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing
instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814, or you may call 916-324-5315, or
ask a water heater dealer.
However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the
local building jurisdiction for acceptable bracing procedures.
PART 1 – GENERAL SAFETY INFORMATION
A. PRECAUTIONS
This water heater is approved for indoor installations only. Clearance to combustible materials: 0” top, bottom, sides and back. Heater
must have room for service: 24” front and 6” sides are minimum recommended service clearances. (A combustible door or removable
panel is acceptable front clearance.) This water heater has been approved for closet installation, and installation on combustible
flooring. Do not install this water heater directly on carpeting.
NOTE: When inquiring about service or troubleshooting, reference the model and serial numbers from the boiler rating label.
4
B. WHEN SERVICING THE WATER HEATING SYSTEM
To avoid electric shock, disconnect electrical supply before performing maintenance.
To avoid severe burns, allow heater to cool before servicing.
C. HEATER WATER
Do not use petroleum-based cleaning or sealing compounds in a water heating system. Gaskets and seals in the system may
be damaged. This can result in substantial property damage.
Do not use “homemade cures” or “heater patent medicines”. Damage to heater, substantial property damage, and/or serious
personal injury may result.
D. INSTALLATIONS IN THE STATE OF CALIFORNIA
Page 5
Failure of electric elements due to lime scale build-up on the heating surface, low pH, or other imbalance IS NOT covered by the
warranty.
UNCRATING HEATER – Any claims for damage or shortage in shipment must be filed immediately against the transportation company
by the consignee. Remove all sides of the shipping crate to allow the heater to be moved into its installation location.
COLD WEATHER HANDLING – If the heater has been stored in a very cold location (BELOW 0oF) before installation, handle with care
until the plastic components come to room temperature.
E. WATER CHEMISTRY
Sodium less than 20mGL.
Water pH between 6.0 and 8.0
oMaintain water pH between 6.0 and 8.0. Check with litmus paper or have it chemically analyzed by water treatment
company.
oIf the pH differs from above, consult local water treatment company for treatment needed.
Hardness less than 7 grains
oConsult local water treatment companies for unusually hard water areas (above 7 grains hardness).
Chlorine concentration less than 100 ppm
o Using chlorinated fresh water should be acceptable as levels are typically less than 5 ppm.
o Do not connect the boiler to directly heat swimming pool or spa water.
o Do not fill boiler or operate with water containing chlorine in excess of 100 ppm.
Drain Valve
Temperature and Pressure Relief Valve
Installation Manual and Warranty
Page 6
SPECIFICATIONS AND DIMENSIONS
WATER TEMPERATURE RATINGS
MODELS
STORAGE
CAPACITY
(GAL)
A
B
HOT / COLD
WATER INLETS
SHIPPING
WEIGHT
(LBS EST.)
MIN.
DELIVERED
TEMP.
MAX.
DELIVERED
TEMP.
HIGH TEMP.
LIMIT
EVR040
40
54 ¼”
19 ½”
¾” NPTM
104
110oF
(43.3 C)
150oF
(65.5 C)
170oF
(76.6 C)
EVR050
50
66 5/8”
118
# ELEMENTS
AND THERMOSTATS
AVAILABLE WATTAGE
VOLTAGE
FULL LOAD CURRENT IN AMPS
Single Phase
2
3,000
240
13
4,500
19
Locate the water heater where any leakage from the relief valve, related piping, tank, or connections will not result in damage to
surrounding areas or lower floors of the building. The water heater should be located near a floor drain, or installed in a drain pan. HTP
WILL NOT be held liable for leakage damages.
B. SPECIFICATIONS AND PERFORMANCE RATINGS
6
Figure 1 – LP-379-J
Table 1 – Specifications and Dimensions – See Table 2 for a Listing of Available Elements
Table 2 – Listing of Elements and Corresponding Voltages / Wattages / Amperages
C. LOCATING THE WATER HEATER
Page 7
Incorrect ambient conditions can lead to damage to the heating system and
put safe operation at risk. Ensure that the installation location adheres to the
information included in this manual. Failure to do so could result in property
damage, serious personal injury, or death.
Failure of water heater or components due to incorrect operating conditions
IS NOT covered by product warranty.
The service life of the water heater’s exposed metallic surfaces, such as the junction box, is directly influenced by proximity to damp
and salty marine environments. In such areas, higher concentration levels of chlorides from sea spray coupled with relative humidity
can lead to degradation of water heater components.
This water heater is certified for indoor installations only. Do not install the water heater outdoors. Outdoor installations ARE NOT
covered by warranty. Failure to install this water heater indoors could result in substantial property damage, severe personal injury, or
death.
This water heater must not be located near flammable liquids such as gasoline, butane, liquefied propane, adhesives, solvents, paint
thinners, etc., as the controls of this water heater could ignite these vapors and cause an explosion, resulting in property damage,
severe personal injury, or death.
Figure 2 – Recommended Clearances
1. Installation Area (Mechanical Room) Operating Conditions
Ensure ambient temperatures are higher than 32oF/0oC and lower than
104oF/40oC.
Avoid continuously high levels of humidity
Never close existing ventilation openings
7
2. Check for nearby connections to:
System water piping
Electrical power
Choose a location for the water heater as centralized to the piping system as possible.
3. Check area around water heater. Remove any combustible materials, gasoline, and other flammable liquids.
4. If the water heater is to replace an existing water heater, check for and correct any existing system problems, such as:
System leaks
Location that could cause the system and water heater to freeze and leak.
Incorrectly-sized expansion tank
5. All piping should be insulated. Additionally, place the water heater so that the drain, controls, and inlets/outlets are easily accessible.
If you do not provide the minimum clearances shown, it might not be possible to service the heater without removing it from the space.
NOTE: When installing in a zero clearance location, it may not be possible to read or view some product labeling. It is recommended to
make note of the water heater model and serial number.
6. This water heater must be installed vertical on a level surface.
Page 8
Dielectric unions or galvanized steel fittings must not be used in a system with this water heater. Doing so WILL VOID the warranty.
Use only copper, brass, or stainless steel fittings. Teflon thread sealant must be used on all connections.
Do not apply heat to the Hot or Cold water heater connections. If sweat connections are used, sweat tubing to the adapter before fitting
adapter to the water connections on the heater. Any heat applied to the water heater connections will permanently damage the dip tube
and/or heat traps. Damages due to improper installation practices ARE NOT covered by warranty.
PART 3 – HEATER PIPING
A. PLUMBING
It is mandatory that all plumbing be done in accordance with federal, local, and state plumbing codes and practices. Failure to properly
install the water heater WILL VOID the warranty. It is also necessary to use both thread tape and pipe dope on all mechanical plumbing
connections.
Use unions on the hot and cold water connections, so that the heater may be easily disconnected for servicing when necessary.
1. Connect cold water line to the connection marked “COLD” on the top of the water heater.
2. Connect hot water line to the connection marked “HOT” on the top of the heater.
3. An opening is provided near the top of the heater for installation of a Temperature and Pressure Relief Valve (T&P Valve).
8
B. THERMAL EXPANSION
A check valve may be installed in the cold water inlet line as a separate backflow preventer, or may be part of a pressure reducing
valve, water meter, or water softener. An “openwater system” refers to a system without a check valve. A “closed water system”
refers to a system with a check valve installed in the cold water inlet line.
As water is heated, it expands in volume and increases pressure within the water system. This action is referred to as “thermal expansion”. In an open water system, expanding water which exceeds the capacity of the system flows back into the city main where
pressure is easily dissipated.
A closed water system prevents expanding water from flowing back into the city main. The resulting thermal expansion can rapidly
increase pressure in the water heater and system piping. This rapid pressure increase can exceed the safety setting of the relief valve,
causing it to operate during each heating cycle. This rapid and repeated expansion and contraction of components in the system can
cause premature failure of system components, including the relief valve and possibly the water heater. Replacing the relief valve will not correct thermal expansion.
A potable hot water expansion tank is required to offset thermal expansion. Expansion tanks are designed with an air cushion built in
that compresses as system pressure increases, thereby relieving the overpressure condition and eliminating repeated operation of the
relief valve. This expansion tank should be installed in the cold water line between the water heater and the check valve, and must be
sized for the entire water volume of the hot water system. See Figure 3.
Other methods of controlling thermal expansion are available. Check with the local water utility to determine if a check valve exists in the cold water inlet line. Contact your installing contractor, water supplier, or plumbing inspector for additional information regarding
thermal expansion.
C. CONDENSATION
Condensation can form on the water heater when it is first filled with water, and may also occur with a heavy water draw and very cold
inlet water temperature. This condition is not unusual and will disappear as the water becomes heated. However, if the condensation
should continue, examine the piping and fittings for possible leaks.
D. INSULATION BLANKETS
Insulation blankets for external use on electric water heaters are not necessary with this water heater. An insulation blanket is meant to
reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds National Appliance Energy
Conservation Act standards with respect to insulation and energy factor requirements, thus making an insulation blanket unnecessary.
The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment, or use of any type of energy
saving or other unapproved devices (other than those authorized by the manufacturer) into, onto, or in conjunction with the water
heater. The use of unauthorized energy saving devices may shorten the life of the water heater and endanger life and property. The
manufacturer disclaims any responsibility for any losses or injuries resulting from the use of such unauthorized devices.
Page 9
If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully
followed.
In addition, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:
Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of the
insulation blanket.
Do not apply insulation to the top of the water heater. This could interfere with the safe operation of the electrical junction box.
Do not cover the jacket access panel(s) to the thermostat(s) and heating element(s), or temperature and pressure relief valve.
Inspect the insulation blanket frequently.
Failure to follow these instructions could result in substantial property damage, severe personal injury, or death.
To avoid water damage or scalding due to relief valve operation:
Discharge line must be connected to relief valve outlet and run to a safe place of disposal. Terminate the discharge line in a
manner that will prevent possibility of severe burns or property damage should the relief valve discharge.
Discharge line must be as short as possible and the same size as the valve discharge connection throughout its entire length.
Discharge line must pitch downward from the valve and terminate at least 6” above the floor drain, making discharge clearly
visible.
The discharge line shall terminate plain, not threaded, with a material serviceable for temperatures of 375oF or greater.
Do not pipe discharge to any location where freezing could occur.
No shutoff valve may be installed between the relief valve and heater or in the discharge line. Do not plug or place any
obstruction in the discharge line.
Test the operation of the relief valve after filling and pressurizing the system by lifting the lever. Make sure the valve
discharges freely. If the valve fails to operate correctly, immediately replace with a new properly rated relief valve.
Test T&P valve at least once annually to ensure the waterway is clear. If valve does not operate, turn the heater “off” and call
a plumber immediately.
Take care whenever operating relief valve to avoid scalding injury or property damage.
FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION,
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
Do not thread a cap or plug into the relief valve under any circumstances! Explosion and property damage, serious injury, or death may
result.
When filling the water heater, open a hot water tap to release air in the tank and piping. The tank must be full of water before the heater
is turned on. Failure to ensure the water heater is full before turning it on will result in damage to the water heater, and could result in
property damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty.
E. TEMPERATURE AND PRESSURE RELIEF VALVE
NOTE: For protection against excessive pressures and temperatures in this water heater, install temperature and pressure protective
equipment as required by local codes, but not less than a combination T&P valve meeting the requirements for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22B / CSA 4.4-M99, by a nationally recognized testing
laboratory that maintains periodic inspection of production of listed equipment and materials. This valve must be marked with a
maximum set pressure not to exceed the marked maximum working pressure of the water heater. Install the T&P valve into the opening
provided and marked for this purpose on the water heater so that discharge water from the valve will not come in contact with any live
electrical parts.
9
F. FILLING THE HEATER
Page 10
10
A temperature limiting or mixing valve is recommended in installations servicing disabled or elderly persons, or children. Take extreme
caution to avoid scalding when temperature limiting or mixing valves are not used.
Table 3
APPROXIMATE TIME / TEMPERATURE RELATIONSHIPS IN SCALDS
120oF
More than 5 minutes
125oF
1 ½ to 2 minutes
130oF
About 30 seconds
135oF
About 10 seconds
140oF
Less than 5 seconds
145oF
Less than 3 seconds
150oF
About 1 ½ seconds
155oF
About 1 second
Make certain that the field installed drain valve is completely closed.
Open the shut-off valve in the cold water supply line.
Open the hot water faucets to allow air to vent from the heater and piping.
Allow sufficient time for the heater to completely fill with water.
G. SCALDING
This heater can deliver scalding water. Be careful whenever using hot water to avoid
scalding injury. Certain appliances, such as dishwashers and automatic clothes washers
may require increased water temperature. By setting the thermostat on this heater to
obtain the increased water temperature required by these appliances, you may create
the potential for scald injury.
To protect against injury, you should install a mixing valve in the water system. This
valve will reduce point of discharge temperature by mixing cold and hot water in branch
supply lines. Such valves are available from your local plumbing supplier.
Table 3 details the relationship of water temperature and time with regard to scald injury and may be used as a guide in determining the
safest water temperature for your applications.
Page 11
Tank must be full of water before power is turned on. Heating elements will be damaged if energized for even a short time while tank is
dry. Failures due to “dry-firing” are NOT covered by warranty.
H. INSTALLATION DIAGRAMS
11
Figure 3 – Piping Detail - NOTE: Drawing is meant only to demonstrate system piping concept. The installer is responsible for
all equipment and detailing required by local codes.
PART 4 – HEATER WIRING
This unit is factory wired to a junction box on top of the water heater for field wiring connection. These heaters are equipped and wired
for the maximum possible input allowable (see Table 2 for listing of inputs and amperage requirements). The voltage requirement and
dedicated wattage load for the heater is specified on the rating label of the water heater. Consult your local power company to
determine if your electrical service is adequate for the additional load of the heater.
Refer to the wiring diagrams below for field connections. All wiring must conform to local code and the National Electric Code, and
should be done by a qualified licensed electrician or the local electric utility. Grounding can be accomplished by using approved conduit
and fittings or other approved conductive material. A grounding wire is provided on the junction bracket. This grounding wire must be
used in the installation.
Page 12
12
Be sure to ground the water heater. The preferred way to ground is with rigid metal conduit between the main panel and the water
heater junction box with approved end fittings (check codes on the use of flexible conduit). If making a separate ground, a green ground
wire is provided in the water heater junction box. Replace the junction box cover and insulation after you have made the wiring
connections.
WATER HEATER LOCATION
YES
NO
Close to area of heated water demand
Indoors and protected from freezing temperatures
Area free of flammable vapors
Provisions made to protect area from water damage
Sufficient room to service heater
WATER SUPPLY
YES
NO
Water heater completely filled with water BEFORE operating the unit
Air purged from water heater and piping
Water connections tight and free of leaks
RELIEF VALVE
YES
NO
Temperature and Pressure Relief Valve properly installed and discharge line run to open drain
Discharge line protected from freezing
Figure 4 - Wiring Detail
PART 5 – INSTALLATION CHECKLIST
Page 13
WIRING
YES
NO
Power supply voltage agrees with water heater rating plate
Branch circuit wire and fusing or circuit breaker of proper size
Electrical connections tight and unit properly grounded
The cause of the high temperature condition must be investigated by a qualified service technician and corrective action must be taken
BEFORE placing the water heater back in service. Failure to do so could result in property damage, severe personal injury, or death.
Risk of scald injury increases as you increase water temperature.
Failure to disconnect power from water heater before attempting to adjust or reset the
thermostat(s) will result in property damage, severe personal injury, or death due to
electric shock.
Figure 5 – Detail of Steps 2 - 4
Table 4 – Installation Checklist
PART 6 – OPERATING THE HEATER
After water and electrical connections have been made and tank is filled with water, turn on power to heater. The heater is now in
operation.
A. COMBINATION THERMOSTAT AND HIGH LIMIT CONTROL (ECO)
This heater is equipped with a combination Thermostat – High Limit Control (ECO), which is located above the heating element (above
the upper element on dual element heaters). If for any reason the water temperature becomes excessively high, the ECO breaks the
circuit to the heating element. Once the switch opens, it must be reset manually.
B. THERMOSTAT ADJUSTMENT AND ECO RESET
IF YOU NEED TO ADJUST THERMOSTAT(S) OR RESET THE ECO (RED
RESET BUTTON):
13
STEP #1 – Turn off power to the water heater by removing fuse or shutting off at circuit
breaker.
STEP #2 – Remove the two screws that hold the access cover in place. Remove the cover.
STEP #3 – Remove the insulation to expose the thermostat.
STEP #4
a. Reset the ECO by pushing in the red button marked “RESET”.
b. Adjust water temperature by turning the white adjustment knob. Turning the knob
to the right (clockwise) makes the water hotter. Turning the knob to the left
(counterclockwise) makes the water cooler.
STEP #5 – Replace the insulation.
Page 14
Failure to replace insulation could result in property damage, severe personal injury, or death.
If heating elements need replacement, it is very important to use the same voltage, wattage, and construction. The element sheath
must be incoloy and the hex plug must be made of stainless steel.
Failure to disconnect power from water heater before attempting heating element replacement will result in property damage, severe
personal injury, or death due to electric shock.
Completely drain the water heater before removing and replacing a heating element or elements. Failure to do so will result in a
leakage of water and property damage, and could possibly result in moderate to severe personal injury or death.
Water drained from the water heater may be scalding hot. Take care to avoid scalding. Wear gloves and safety glasses, and direct
water to a safe drainage location. Failure to comply with this warning could result in substantial property damage, severe personal
injury, or death due to scalds.
DO NOT replace heating element with a generic heating element. Only HTP heating elements are approved for use with this water
heater. Failure to follow this warning will result in premature product failure and VOID the warranty.
Figure 6 – Heating Element Detail
STEP #6 – Reattach the access cover with the two screws.
STEP #7 – Restore power by replacing the fuse or turning on the circuit breaker.
STEP #8
a. After resetting the ECO, ensure the water heater is operating properly before leaving the installation.
b. After adjusting the water temperature, allow the water heater enough time to heat the water to temperature. After the water
heater has stopped heating, measure the water temperature at a hot water outlet in the structure.
STEP #9 – If the water heater is operating properly and the water temperature is satisfactory, adjustment is complete.
C. HEATING ELEMENT REPLACEMENT PROCEDURE
STEP #1 – Turn off power to the water heater. Use a Phillips Head screwdriver to remove wires connecting the element to the
thermostat.
14
STEP #2 – Run hot water at a faucet in the system. When it runs cold, shut off the faucet. Then shut off water at the main cold water
inlet, or, if possible, valve off the water heater from the system. Drain the water from the system, or just the water heater if you can
isolate it from the system.
STEP #3 – Remove the
element with a 1 ½” socket
wrench or element tool.
STEP #4 – Ensure thread
and opening are completely
free of debris.
STEP #5 – Put a small
amount of NSF approved
lubricant and sealant on the
O-Ring.
STEP #6 – Screw the
element clockwise into tank,
and tighten with the 1 ½” socket wrench or element tool. Be sure O-ring seats properly.
Page 15
15
When filling the water heater, open a hot water tap to release air in the tank and piping. The tank must be full of water before the heater
is turned on. Failure to ensure the water heater is full before turning it on will result in damage to the water heater, and could result in
property damage, serious personal injury, or death. Such damages ARE NOT covered by water heater warranty.
Failure to refill the tank before restoring power to the water heater will result in damage to the heating elements and property damage.
Such damages ARE NOT covered by warranty.
Failure to shut off power to the heater when draining may damage the heating elements. Operating a partially filled/empty water heater
could lead to damage from “dry-firing”. Failures due to such damage are NOT covered by warranty.
Water drained from the water heater may be scalding hot. Take care to avoid scalding. Wear gloves and safety glasses, and direct
water to a safe drainage location. It is recommended to turn power off to the water heater and run the water at a hot faucet until it cools
BEFORE draining water from the heater. Failure to comply with this warning could result in substantial property damage, severe
personal injury, or death due to scalds.
NOTE: REPEAT STEPS 3 – 6 AS NECESSARY FOR MULTIPLE ELEMENTS
STEP #6 – Open the main cold water inlet. If the water heater has been isolated from the system, open the valves. Refill the tank with
cold water. Open a hot water faucet high in the system to bleed any air pressure from the system. Water will flow freely when air is
completely bled.
STEP #7 – Pressure check the tank for leaks around element. If no leaks are found, connect wires from the element to the thermostat.
STEP #8 - Turn power back on to the water heater.
PART 7 – MAINTENANCE
MAINTENANCE CONSIDERATIONS
To avoid electric shock, disconnect electrical supply before performing maintenance.
To avoid severe burns, allow heater to cool before performing maintenance.
NOTE: In addition to the routine maintenance detailed in this manual, this water heater should be inspected annually by a qualified
service technician to assure that all the equipment is operating safely and efficiently. The owner should make necessary arrangements
with a qualified heating contractor for periodic maintenance of the heater. Installer must also inform the owner that lack of proper care
and maintenance may result in a hazardous condition, premature heater failure, and void the warranty.
Routine preventative maintenance ensures the water heater operates safely and efficiently over its service life. The Owner/User may
perform the maintenance activities described below.
Monthly (Every two weeks in hard water locations)
It is recommended that a few quarts of water be drained from the heater. This will flush sediment deposits from the bottom of the heater
and lengthen the heater’s service life. Turn off power to the heater during flushing operation, so the elements will not be damaged.
To flush the tank, attach a hose to the field installed drain valve in the cold water supply line. Close supply line shut-off valve. Open
drain line valve and hot water faucet(s) to vent heater while draining. Direct the flow of water to a drain or bucket where it will not cause
damage.
After flushing until water runs clear, operation is complete. Close drain valve and reopen supply line shut-off valve. Make certain that
heater is completely full of water before restoring power to the heater.
Periodically (At least twice a year)
Check around the water heater and related plumbing for leaks. If the combination temperature and pressure relief valve discharges
periodically, or water is leaking from around the heating elements, there may be a problem with your water system. DO NOT ATTEMPT
TO REPAIR LEAKS YOURSELF! Contact a qualified service contractor for assistance.
Check the area around the water heater for flammable liquids or combustible materials. If any are found, remove from the area.
Page 16
16
T&P Relief Valve Maintenance Instructions:
Annually: Certain naturally occurring mineral deposits may adhere to the valve, blocking waterways and rendering the valve
inoperative. The T&P Relief Valve lever must be operated to ensure the waterways are clear. If waterways are clear, hot water
will discharge from the valve. Take precautions to avoid personal injury and property damage from contact with hot water.
Before operating lever, check to see that a discharge line is connected to the valve, directing the flow of hot water from the
valve to a proper place of disposal.
Replacement of the valve is required if no water flows when the lever is operated. Turn the water heater off until the valve is
replaced.
If water flows from the relief valve, drain a few gallons from the tank to ensure water flows freely.
At least once every three years: To ensure that the T&P relief valve has not been affected by corrosive water conditions and
that the valve and discharge line have not been altered or tampered with illegally, relief valves should be inspected, and
replaced, if necessary, by a licensed plumbing contractor or qualified service technician.
FAILURE TO COMPLY WITH THE ABOVE GUIDELINES COULD RESULT IN FAILURE OF RELIEF VALVE OPERATION,
RESULTING IN POSSIBILITY OF SUBSTANTIAL PROPERTY DAMAGE, SEVERE PERSONAL INJURY, OR DEATH.
ISSUE
POSSIBLE CAUSE
SERVICE REMEDIES
No Hot Water
1. Manual disconnect switch turned off
2. Improper Wiring
3. No Power – blown fuse or circuit breaker tripped
a. Shorted wiring
b. Circuit overloaded
c. Improper wiring
d. Grounded element or thermostat
4. Manual Reset High Limit Switch (ECO) open
a. Thermostat(s) defective
b. Thermostat out of calibration
c. Heat build-up due to loose wires
d. Defective High Limit Switch (ECO)
1. Turn switch ON
2. *Rewire per Fig. 5, Wiring Detail
3. Replace fuse or reset breaker
a. *Replace or repair
b. *Provide adequate circuit to
reduce load
c. *Rewire per diagram
d. *Replace
4. Refer to Part 5, Sections A and B, this manual
a. *Replace thermostat
b. *Lower thermostat setting or replace
c. *Tighten wire connections
d. *Replace
Not enough Hot Water
1. Heater undersized
2. Defective Element(s)
3. Miswired or defective thermostat causing only
one element to work
1. Reduce rate of hot water use
2. *Check amperage, replace
element if low
3. *Check wiring or replace
Vacation (Extended Shut-Off Periods)
During extended mild or warm weather periods when hot water will not be in use, shut off the electric power to the tank. When hot water
is needed again, restore power to the water heater.
During extended cold weather periods when hot water will not be in use and prone to freezing conditions, shut off electric power to the
tank, close the supply line shut-off valve, open the drain valve and drain the water heater to a safe drainage location (as detailed
previously). Once drained, close the drain valve. When hot water is needed again, restore the water supply to the tank. Once the tank is
full, restore power.
The maintenance activities described below are only to be performed during service by the Installer/Qualified Service Provider.
These maintenance items should be performed during recommended annual service and any service calls.
1. Ask the owner / user if there have been any issues with the water heater. Diagnose any heater issues and repair / replace parts as
necessary.
2. Check the water heater and related plumbing for leaks. Repair any that are found.
3. Check the area around the water heater for flammable liquids or combustible materials. If any are found, remove from the area.
4. Check the heating elements while the heater is in operation. If the elements are hissing / singing excessively, they may need to be
cleaned. Inspect the elements and clean if necessary.
5. Inspect the Temperature and Pressure (T&P) Relief Valve. See instructions below.
6. Turn power supply off to the water heater. Open the drain valve and drain a few gallons of water from the tank to clear the tank of
any hard water deposits. Once complete, close the drain valve and restore power to the water heater.
PART 8 – TROUBLESHOOTING
The following table details operating issues, possible causes, and service remedies.
Page 17
Water too hot or not hot
enough
1. Thermostat setting too high or low
2. Thermostat out of calibration
3. Thermostat access panel(s) and/or insulation
not in place
4. Thermostat(s) not resting tightly against
mounting plate
1. Change setting as required
2. *Replace
3. Inspect and replace as needed
4. Inspect and insure that retaining spring(s) or
mounting screws hold thermostat(s) tightly to
mounting plates
Noisy heating
element(s)
Hard water scale built up on element(s)
*Remove and clean
Water leaks
1. Loose connection between inlet/outlet piping,
relief valve, or drain valve and hex nut union on
tank fittings
2. Damaged seal ring washer
3. Gasket around heating element(s)
1. Tighten hex nut union fitting
2. Replace seal rings as required
3. Inspect and replace gasket if necessary
Leaking Temperature
and Pressure Relief
Valve
1. Improperly seated valve
2. Thermal expansion in closed water system
3. Damaged/defective valve
1. Attempt to reseat valve by opening and closing
handle
2. Install a thermal expansion tank
3. Replace relief valve
NOTE: DO NOT plug T&P valve under any
circumstances
Hot Water Odor
1. High sulfate or mineral content in water supply.
2. Bacteria in water supply.
1. Drain and flush water heater. Refill
2. Check with local water treatment specialist or
utility to identify and address this problem.
Table 5 – Troubleshooting – *NOTE: This maintenance should only be performed by a qualified service provider.
17
Page 18
18
Figure 7 –Parts Blowout
Page 19
19
NOTES
Page 20
Customer’s Name:
Installation Address:
Date of Installation:
Installer’s Code/Name:
Product Serial Number(s):
Comments:
Installer’s Phone Number:
Signed by Installer:
Signed by Customer:
HTP CUSTOMER INSTALLATION RECORD FORM
The following form should be completed by the installer for you to keep as a record of the installation in case of a warranty claim. After
reading the important notes at the bottom of the page, please also sign this document.
20
IMPORTANT:
Customer: Please only sign after the installer has reviewed the installation, safety, proper operation, and maintenance of the
system. In the case that the system has any problems, please call the installer. If you are unable to make contact, please
contact your HTP Sales Representative.
P.O. Box 429 ∙ 120 Braley Road ∙ East Freetown, MA 02717 ∙ 508-763-8071∙ Fax: 508-763-3769
Everlast Stainless Steel Electric Water Heater
Residential Limited Warranty
HTP warrants each residential stainless steel electric water heater to be free from defects in materials and workmanship according to the following
terms, conditions, and time periods. The number of replacement water heaters is limited to one (1) per original unit purchased. Replacement parts will be
warranted for 90 days. UNLESS OTHERWISE NOTED THESE WARRANTIES COMMENCE ON THE DATE OF INSTALLATION. This limited warranty
is only available to the original owner of the water heater, and is non-transferable.
Residential Use
“Residential” setting shall mean water heater usage in a single family dwelling, or usage in a multiple family dwelling, provided that the water heater
services only one (1) dwelling in which the original consumer purchaser resides on a permanent basis and operating temperatures do not exceed 140oF.
Commercial Use
Water heaters used in any setting not falling within the “Residential” setting definition shall be defined as “Commercial” and warranted as described
under the Everlast Stainless Steel Electric Water Heater Commercial Limited Warranty (lp-425).
Extended Residential Limited Warranty coverage shall apply to residential water heaters registered with HTP, Inc. online at htproducts.com within 90
days of the installation date. See information provided on the following page of this document for registration details.
Standard Limited Warranty (One (1) year – Parts, Ten (10) years – Tank)
Standard Limited Warranty coverage shall apply to residential water heaters NOT registered with HTP, Inc. within 90 days of the installation date.
COVERAGE
A. During the first year after the original date of installation in the dwelling, HTP warrants that it will repair or replace, at its option, any defective or
malfunctioning component of the stainless steel electric water heater with a component of equivalent size and current model. Replacement components
will be warranted for ninety (90) days. It is expressly agreed between HTP and the original consumer purchaser that repair or replacement are the
exclusive remedies of the original consumer purchaser.
B. Should a defect or malfunction result in a leakage of water within the above-stated warranty periods due to defective material or workmanship,
malfunction, or failure to comply with the above warranty, HTP will replace the defective or malfunctioning water heater with a replacement of the nearest
comparable model available at the time of replacement. The number of replacement water heaters is limited to one (1) per original unit purchased.
C. If HTP is unable to repair or replace the water heater so as to conform to this warranty after a reasonable number of attempts, HTP will then provide,
at its option, a replacement unit. These remedies are the purchaser’s exclusive remedies for breach of warranty.
D. If government regulations, industry certification, or similar standards require the replacement water heater or part(s) to have features not found in the
defective water heater or part(s), the owner will be charged the difference in price represented by those required features. If the owner pays the price
difference for those required features and/or to upgrade the size and/or other features available on a new replacement water heater or part(s), the owner
will also receive a complete new limited warranty for that replacement water heater or part(s).
E. If at the time of a request for service the owner cannot provide a copy of the original sales receipt or the warranty registration, the warranty period for
the water heater shall then be deemed to have on the date of manufacture of the water heater and NOT the date of installation of the water heater, and
be covered by the unexpired portion of the Standard Limited Warranty detailed above.
F. This warranty extends only to water heaters utilized in heating applications that have been properly installed by qualified professionals based upon the
manufacturer’s installation instructions.
OWNER RESPONSIBILITIES
To avoid the exclusion list in this warranty, the owner or installer must:
1. Have a vacuum relief valve and temperature and pressure relief valve bearing the listing marks of the American Society of Mechanical Engineers
(ASME) installed with the water heater assembly in accordance with federal, state, and local codes.
2. Operate the water heater assembly at water pressures not exceeding the working pressure shown on the rating plate.
3. Keep the water heater free of damaging scale deposits.
4. Use the water heater in an open system, or in a closed system with a properly sized and installed thermal expansion tank.
5. Make provisions so if the water heater or any component part or connection thereto should leak, the resulting flow of water will not cause damage to
the area in which it is installed.
WARRANTY EXCLUSIONS
This limited warranty will not cover:
1. Any water heater purchased from an unauthorized dealer or online retailer.
2. Any water heater not installed by a qualified heating installer/service technician.
3. Service trips to teach you how to install, use, maintain, or to bring the water heater installation into compliance with local building codes and
regulations.
4. Failure to locate the water heater in an area where leakage of the tank or water line connections and the combination temperature and relief valve will
not result in damage to the area adjacent to the water heater or lower floors of the structure.
5. Any failed components of the heat system not manufactured by HTP as part of the water heater.
6. Water heaters repaired or altered without the prior written approval of HTP.
7. Damages, malfunctions, or failures resulting from failure to install the water heater in accordance with applicable building codes/ordinances or good
plumbing and electrical trade practices.
Page 22
22
8. Damages, malfunctions, or failures resulting from improper installation, failure to operate the water heater at pressures not exceeding the working
pressure shown on the rating plate, or failure to operate and maintain the water heater in accordance with the manufacturer’s provided instructions.
9. Damages, malfunctions, or failures caused by operating the water heater with modified, altered, or unapproved parts.
10. Failure to operate the water heater in an open system, or in a closed system with a properly sized and installed thermal expansion tank.
11. Failure or performance problems caused by improper sizing of the water heater, expansion device, or piping.
12. Damages, malfunctions, or failures caused by abuse, accident, fire, flood, freeze, lightning, acts of God and the like.
13. Failures (leaks) caused by operating the water heater in a corrosive or contaminated atmosphere.
14. Failure of the water heater due to the accumulation of solid materials, lime deposits, water quality contrary to the manufacturer’s provided
instructions. WATER CHEMISTRY REQUIREMENTS – Sodium less than 20mGL. Water pH between 6.0 and 8.0. Hardness less than 7 grains. Chlorine
concentration less than 100 ppm.
15. Any damages, malfunctions, or failures resulting from the use of dielectric unions.
16. Production of noise, taste, odors, discoloration, or rusty water.
17. Damages, malfunctions, or failures caused by subjecting the tank to pressures greater than those on the rating label.
18. Water heaters installed outside the fifty states (and the District of Columbia) of the United States of America.
19. Water heaters moved from the original installation location.
20. Water heaters that have had their rating labels removed.
21. Water heaters replaced for cosmetic reasons.
ONLINE EXTENDED LIMITED WARRANTY REGISTRATION
To register for the Extended Limited Warranty, complete the form located on the HTP website at http://www.htproducts.com/warranty within 90 days of
installation. The form must be completed in full with owner name, email address, and phone number, the address where the unit is installed and
installation date, and unit model and serial numbers. Proof of purchase is required, and may be an invoice for the product, or a bill from an installing
contractor that clearly documents the installation of the unit. To be valid, proof of purchase must also include the unit serial number. Proof of purchase
may be typed or hand written. Submit the proof of purchase to HTP, Inc. via the directions provided on the website.
PROCEDURES FOR WARRANTY SERVICE REQUESTS
Any claim for warranty assistance must be made promptly. Determine if the water heater is “in-warranty” (that is, within the applicable warranty period)
by reviewing a copy of the original sales receipt. You must present a copy of the original sales receipt for a warranty service request.
If your water heater is “in-warranty”, contact the retailer from whom the water heater was purchased (or the installer) for assistance. Be prepared to
provide the retailer or installer with a copy of your original receipt, complete model and serial numbers, and the date of installation of your water heater,
in addition to explanation of your water heater problem.
Warranty coverage is subject to validation of “in-warranty” coverage by HTP claims department personnel. All alleged defective or malfunctioning parts
must be returned to HTP via the local distribution channels where original purchase was made. NOTE: Any parts or heaters returned to HTP for warranty analysis will become the property of HTP and will not be returned, even if credit is denied.
If all warranty conditions are satisfied, HTP will provide replacement parts to the retailer.
If you have questions about the coverage of this warranty, please contact HTP at the address or phone number stated below:
HTP
P.O. Box 429 120 Braley Road
East Freetown, MA 02717
Attention: Warranty Service Department
1(800) 323-9651
SERVICE, LABOR AND SHIPPING COSTS
This limited warranty does not extend to any shipping charges, delivery expenses, or administrative fees incurred by the purchaser in repairing or
replacing the water heater or part(s). This warranty does not extend to labor costs beyond the coverage specified in this warranty document. All such
expenses are your responsibility.
LIMITATIONS OF YOUR HTP WARRANTY AND REMEDIES
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY OBLIGATION,
LIABILITY, RIGHT, CLAIM OR REMEDY IN CONTRACT OR TORT, WHETHER OR NOT ARISING FROM HTP’S NEGLIGENCE, ACTUAL OR IMPUTED. THE
REMEDIES OF THE PURCHASER SHALL BE LIMITED TO THOSE PROVIDED HEREIN TO THE EXCLUSION OF ANY OTHER REMEDIES INCLUDING WITHOUT
LIMITATION, INCIDENTAL OR CONSEQUENTIAL DAMAGES, SAID INCIDENTAL AND CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO,
PROPERTY DAMAGE, LOST PROFIT OR DAMAGES ALLEGED TO HAVE BEEN CAUSED BY ANY FAILURE OF HTP TO MEET ANY OBLIGATION UNDER THIS
AGREEMENT INCLUDING THE OBLIGATION TO REPAIR AND REPLACE SET FORTH ABOVE. NO AGREEMENT VARYING OR EXTENDING THE FOREGOING
WARRANTIES, REMEDIES OR THIS LIMITATION WILL BE BINDING UPON HTP. UNLESS IN WRITING AND SIGNED BY A DULY AUTHORIZED OFFICER OF HTP.
THE WARRANTIES STATED HEREIN ARE NOT TRANSFERABLE AND SHALL BE FOR THE BENEFIT OF THE ORIGINAL PURCHASER ONLY.
NO OTHER WARRANTIES
Your HTP warranty gives you specific legal rights, and you may also have other rights that vary from state to state. Some states do not allow the
exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you.
These are the only written warranties applicable to the water heater manufactured and sold by HTP. HTP neither assumes nor authorizes anyone to
assume for it any other obligation or liability in connection with said water heaters.
HTP reserves the right to change specifications or discontinue models without notice.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.