FHD264
14
© Copyright 2018 Hall Research, Inc.
All Commands are Terminated
by <CR><LF> (or Hex 0D 0A)
Response Function
set_downscale_mode string(fhd|hd|sd)] to
string(fhd|hd|sd)]
OK – Success
Error – Fail
Scale down the input video to
lower resolution
get_downscale_mode string(fhd|hd|sd)]
(Sender ONLY)
string(fhd|hd|sd)] Get the downscale mode status
set_video_out_mode
string(both_on|loopthrough|network|both_off)]
(Sender ONLY)
OK – Success
Error – Fail
Enable the HDMI output and
network output
get_video_out_mode
(Sender ONLY)
string(both_on|loopthrough|network|both_o
ff)]
Query the Loop and network
output status
set_osd [string(auto|on|off)]
Auto= OSD will turn off when there is an input
signal detected.
On or Off – OSD Stays on or off forever
OK – Success
Error – Fail
Set OSD mode of the system
get_osd Auto
On
Off
Query the OSD mode status
set_device_name [string (1~30)]
Where string can be 30 characters long
OK – Success
Error – Fail
Set the device name
get_device_name [string (1~30)] Query the device name
get_fw_version Tx/Rx Firmware : x.x.x.x.xxxxxxxx
Returns the firwmare version
Query the firmware version
factory_reset Processing factory reset!
System will reboot after few sec!
Factory reset the device
Reboot System will reboot after few sec! To reboot the unit
get_company_id xxx Query the company ID
set_streaming_mode [string(unicast|multicast)] OK – Success
Error – Fail
Set the streaming mode of the
device
get_streaming_mode [string(unicast|multicast)] [string(unicast|multicast)]
where unicast means one-one
configuration and
multicast means one to many and manyto-many configuration
Query streaming mode status
master_get xxx.xxx.xxx.xxx (IP Address)
[Blank]
Return the IP address of
registered 3rd party controller for
SoIP
master_set
[string(xxx.xxx.xxx.xxx)]
Master Set Registers the IP address as 3rd
party controller. All the responses
from the serial device connected
to RS-232 port will be sent to the
server on port #5050 at this IP
address
rs_out
[string( up to 100 char)]
SoIP Sent Outputs the string the string via
RS-232
get_failsafe (Receiver ONLY) on
off
Returns the fail safe status
set_failsafe
[string(on|off)] (Receiver ONLY)
Ok -- Successes
Error -- Fail
Set the fail safe status
set_fs_group n
where n = 0 to 63 (Receiver ONLY)
Ok -- Successes
Error -- Fail
Set the fail safe group number
get_fs_group (Receiver ONLY) Number in range 0 to 63 Returns the fail safe group number