HPM R620 Instruction Information

Page 1
Fan Light - Ceiling Exhaust
Fan and Light
Cat. R620
Instruction Information
1 Installation
1. Determine position in ceiling where Fanlight is required to be installed. (Do not install within 120cm of stove or inside a shower recess). Be certain that the installation area is not restricted by roof beams above ceiling.
5. Remove light diffuser and air-intake grille. Unscrew the 3 screws on the lip of the unit until the gap between the toggles and inner lip of the unit is greater than the width of the Gyprock, or other ceiling material. Fold these toggles in. Push unit into hole.
A licensed electrician is required to connect this unit to the mains supply.
6. Turn the retention screws clockwise. The toggles will splay out. Tightening the retention screws allows the toggles to grip the ceiling material.
7. It is recommended that the three toggles be checked for the correct clamping by inspection from above.
8. You may now insert a globe (not more than 75W) into the lampholder. Push grille into unit and click into position. Assemble the diffuser and round dust seal and twist into position. To remove this assembly for cleaning, simply pull assembly downwards. For globe changing only, simply twist the diffuser anticlockwise and remove.
2. Use template provided to draw a circle 300mm in diameter. To do this insert a thumb tack in hole at one end and insert a pencil in the other hole and scribe a circle.
3. Use electric jig saw or small hand saw to cut out around this line. Several holes drilled at a point inside the circle provides a convenient starting point for cutting the panel out.
4. Remove terminal cover and wire according to the diagram in Option 1 over. This method of wiring switches fan and light on and off simultaneously. Option 2 shows how to wire fan and light separately. This allows the light (or the fan) to be switched on independently of the other. Option 3 shows the addition of a HPM Cat TX770/1RC time delay mechanism.
Page 2
Variable field of view
2
3
4
5
Switching arrangements Specifications
Product parts
Warning
Supply voltage: 240V a.c. 50Hz Maximum Power Consumption: 113W Lamp: 75W (Max) Fan: 38W Ceiling cut-out: 300mm Protrusion from ceiling: 90mm Projection into ceiling: 130mm Impeller diameter: 200mm Weight (Normal): 3.0kg
INSTALLATION/APPLICATION
Terminal block & cover
Motor housing
Reflector
Retention screws
Lampholder
Fan blade
Fan intake
Option 1: Fan and light switched together
Fan/Light switch
1
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
K: Double pole disconnection switch or 2 pin plug
INSTALLATION/APPLICATION
Terminal block & cover
Motor housing
Reflector
Dust seal
Retention screws
Lampholder
Fan blade
Fan intake grille
Light diffuser
INSTALLATION/APPLICATION
Terminal block & cover
Motor housing
Reflector
Dust seal
Retention screws
Lampholder
Fan blade
Fan intake grille
Light diffuser
Option 1: Fan and light switched together
Option 2: Fan and light switched seperately
Fan/Light switch
Fan switch
Light switch
1
1 2
C
1 2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
K: Double pole disconnection switch or 2 pin plug
K: Double pole disconnection switch or 2 pin plug
INSTALLATION/APPLICATION
Terminal block & cover
Motor housing
Reflector
Dust seal
Retention screws
Lampholder
Fan blade
Fan intake grille
Light diffuser
Option 1: Fan and light switched together
Option 2: Fan and light switched seperately
Option 3: Fan and light switched together with time
delay on fan after switch is turned off
Fan/Light switch
Fan switch
Light switch
1
1 2
C
Fan/Light Switch
HPM Cat. TX770/1RC
to light to fan
1 2
C
1
2
C
2
C
N L
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
FAN
A
A
LOOP
NEUTRAL
LIGHT
N L
N L
K: Double pole disconnection switch or 2 pin plug
K: Double pole disconnection switch or 2 pin plug
K: Double pole disconnection switch or 2 pin plug
Warranty
HPM Legrand will honour all statutory guarantees that you as a consumer are entitled to rely upon under the Australian Consumer Law against a manufacturer including a guarantee that products are of acceptable quality. To make a claim under any statutory guarantee (or other warranty) you should first contact the supplier, contractor or retailer from whom you purchased the products.
Customer Service
For all Customer Service and Technical Support please call Monday to Friday during business hours.
HPM Legrand Australia 1300 369 777 www.hpmlegrand.com.au
HPM Legrand New Zealand 0800 476 009 www.hpmlegrand.co.nz
ABN: 31 000 102 661
LE05800ADA
WARNING:
Ensure the fan is switched off from mains supply before removing grille and diffuser for cleaning purposes.
Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Loading...