HPM EF150SQWE, EF150RDWE, EFS150SQWE, EFS150SQSWE, EF150SQSWE Instruction Sheet

Page 1
EF150SQWE Standard square 150mm wall fan
EFS150SQWE Standard 150mm wall fan with auto shutter
Cat no. EF150SQWE, EF150SQSWE, EF150RDWE, EFS150SQWE, EFS150SQSWE
Instruction Sheet
1 Specifications
For indoor use only. Airflow will be reduced with bends in duct, squashing of duct, restrictions on replacement air entering the room to be ventilated, or pressure-differentials between the room and outside air. The length of the duct will have an effect on the airflow. When fitted, the wall kit (R621/6D) must be at the same height or lower than the exhaust fan.
EF150SQSWE Slimline square 150mm wall fan
EFS150SQSWE Slimline 150mm wall fan with auto shutter
EF150RDWE Round 150mm wall fan
Cat no. EF150SQWE EF150SQSWE EF150RDWE EFS150SQWE EFS150SQSWE
Supply voltage 230–240V a.c. 50Hz Power rating 24W Protection class Class II IP rating IP44 IP24 IP24 IP44 IP24 Duct requirement Ø150mm Wall/ceiling cut-out size Ø160mm Draught stopper PET Sheet Auto-Shutter (Wax Solenoid) Fascia Size 212x212mm 212x212mm Ø253mm 212x212mm 212x212mm
Thickness 43mm 24mm 24mm 43mm 24mm
Weight (excl. packaging) 1.0kg 0.9kg 0.9kg 1.2kg 1.1kg
Cat no. EF150SQWE EF150SQSWE & EF150RDWE EFS150SQWE EFS150SQSWE
Draught stopper with without with without with with No duct 204 218 269 309 200 267 Wall kit R621/6D
(350mm of duct)
184 189 206 217 184 206
1m of duct 175 178 196 201 175 196 3m of duct 158 160 171 181 158 171
Max Airflow (m3/hr)
Please read carefully: Read through these instructions completely before commencing installation. Retain for future use.
This product should be installed by a licensed electrical contractor or similarly qualified person.
Page 2
CAUTION:
Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside. Locate in accordance with the requirements of the Wiring Rules AS/NZS 3000 relating to damp situations.
Note: Steam will only be removed if there is sufficient flow of air through the room. Ensure adequate inlet openings in the room are provided,
for example through windows, vents or under the door. Air-flow paths from room inlets to fan should ideally pass over surfaces where condensation may form.
2 Mounting
These exhaust fans are designed primarily for wall-mounting. They may be vented in to a cavity wall or in to the roof space in the ceiling.
Alternatively, the fan may be ducted through an outside wall (with the addition of ducting and an outside grille). Protrusions into wall/ceiling cavity are as per below figures.
The flaps of the Auto-Shutter are driven by a thermoactuator. Due to this, the flaps will take time to open/close when the exhaust fan is switched on/off. Time to Open: 30 – 60 seconds Time to Close: 120 – 200 seconds
Duct
Ceiling
250mm
Draft Stopper
Duct
Ceiling
96mm
160mm
250mm
Wall/Ceiling
Wall/Ceiling
Fan with duct
Fan with draught stopper Fan with auto shutter and duct
Fan with auto shutter
Fan only
Draft Stopper
160mm
250mm
Wall/Ceiling
Ceiling
Duct
310mm
150mm
Wall/Ceiling
Auto-Shutter
ROOF VENT CAP
ROOFING
When fitted, the duct outlet must be the same height or lower than the exhaust fan.
The duct must not be installed vertically into a roof vent cap – the product is not designed or intended for this type
of installation.
3
Auto-Shutter (for EFS150SQWE & EFS150SQSWE only)
Page 3
Warranty
HPM Legrand warrants this product for a period of 3 years from the date of purchase. These goods come with guarantees that cannot be excluded under the Australian and New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired if the goods fail to be acceptable quality and the failure does not amount to a major failure. See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support please call Monday to Friday during business hours.
HPM Legrand Australia HPM Legrand New Zealand 1300 369 777 0800 476 009 www.hpm.com.au www.hpm.co.nz
ABN: 31 000 102 661
4
5
6
7
Installation
Cleaning
Optional Accessories
Disclaimers
Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before
commencing work.
1. Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draught-stopper and/or ducting. Refer to section 2 for further information.
2. If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer to Optional Accessories section.
3. Time-delay module is available separately, please refer to Optional Accessories section.
4. Make a circular 160mm hole in the wall/ceiling.
5. Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6. Remove draught-stopper if not required. Note that the draught-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below).
8. Ensure orientation of fan is with arrow pointing↑up.
9. Fix fan firmly to the wall with the 4 screws provided.
10. Replace front cover/fascia and tighten fixing screw. Replace cap.
11. Switch on and test function. Use a paper tissue held against fan inlet to verify suction.
This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used. Ensure the fan is switched off from the mains power supply before removing the grille / fascia.
R621/6D – 150mm wall duct kit EF100/150TD – Time delay module allows the fan to run for a set period, adjustable between 1 - 29 mins, after the switch has been turned off.
Fan
mounting
orientation
Cable entry from rear
Cord entry from side for plug and lead (knock-out provided)
N Neutral
L Switched Active
from wall switch
Fixing screw position of fascia
Figure 1.
Figure 2. Fan with timer module and light fitting
1. This product must be installed and used as per these instructions. 2. This product is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 3. This product is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with dust. Under these conditions the life of the fan motor can be significantly reduced. 4. This product should not be enclosed in thermal insulation as it may cause the unit to overheat. 5. This product has been designed to operate in ambient temperatures -10°C to 40°C. 6. This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded. 7. Airflows listed in this product indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, for the appropriate airflow required for a particular installation. 8. Ventilation products must have an adequate source of external air to ensure correct performance. 9. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the duct will not run back into the fan housing. 10. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances. 11. This product has been designed for domestic or similar uses and is not suitable for a commercial installation. 12. This product is not suitable for installation in hazardous and/or corrosive areas. 13. Extended exposure to UV rays (such as exposure to direct sunlight) may cause discolouration of this product. 14. The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed. 15. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property remains the property of HPM Legrand in all cases. 16. HPM Legrand reserves the right to modify the specification of this product at any time.
Active
L
N
LS
Neutral
Connection from rear – bring mains wiring through
cable entry hole.
Connection from side (Fan only) – use twin flat core
(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm
2
and place under cable clamp provided.
Timer
LE06397ATA HPML0703
LE06397ATA
Loading...