Excel and Linea
Dual USB Charger Mechanism
Cat no. 770USB2PSAMWE
770USB2PSAMBL
770USB2PSXMWE
770USB2PSXMBL
Instruction Sheet
770USB2PSAMWE
770USB2PSAMBL
770USB2PSXMWE
770USB2PSXMBL
12 Features
Cat No. 770USB2PSAMWE, 770USB2PSAMBL, 770USB2PSXMWE, 770USB2PSXMBL
Ouput: 5V d.c. ± 5% 4.8 A
Input current 10A (GPO): 230-240V a.c. 50Hz
Mains connections: Via ‘A’ and ‘N’ wires
Standby power consumption: ‹ 0.07W
Overload protection on output: 5.1A
NOTE: USB charger mechanism can be assembled with Excel and Linea powerpoints and switch plates (if Neutral is available) and
powerpoints with extra function hole.
Installation
Installation in powerpoints
1. Push USB mechanism into extra function hole with arrows facing up as shown.
2. Join wires with corresponding Mains cables in the ‘A’
and ‘N’ terminals of powerpoint.
Installation in switch plates
1. Push USB mechanism into extra function
hole with arrows facing up as shown.
2a. Configuration with USB mechanism stand alone in plate.
Connect USB module wires to the mains cable via insulated
connectors (401 series) as per diagram below.
WIRING OF USB DRIVER
TO MAINS WIRING WITH 401
CONNECTOR (REQ. NEUTRAL)
Insulated
connetors
401
Mains cable
2b. Configuration with USB mechanism installed
next to a switch on a plate. Connect USB
wires to switch mechanism as per below.
(TO LIGHT)
NEUTRAL
IN
MAINS
USB
MAINS
USB
ACTIVE
IN

Installation on brick veneer
1. Push assembled unit into the wall cavity. 2. Screw the unit to wall with standard mounting accessories and then fix front plate.
Brick wall
Plasterboard
Cable tie box to
Mains cable to avoid
strain on USB mechanism
Wall cavity
Metal
bracket
Brick wall
0.8 Nm
Installation with wall box for 770USB2PSXMWE / 770USB2PSXMBL
1
CLICK
Plasterboard
Connect USB wires with corresponding
mains cables with the “A” and “N” terminals
of the powerpoint
Metal wall box 435
Push assembled unit
into the wall cavity
Mains cable
2
Wall cavity
0.8Nm
Plasterboard
Mains cable
Brick wall

Installation with wall box and 3m USB extension lead (EAUSBEXT3WE) for 770USB2PSXMWE / 770USB2PSXMBL
1
USB driver
Mains cable
Insulation area
Ceiling
CLICK
Connect mains cables to GPO
Plasterboard
Note:
• In application requiring the 3m USB extension lead, it shall not share the same conduit as the 240V a.c.
mains wiring in accordance with the Wiring Rules.
• The 3m extension lead is suitable for a standard Ø20mm conduit.
• Do not cover this USB driver with insulating matting or similiar material under any circumstances.
Connect USB wires with
corresponding mains cables.
Use junction box 404 or equivalent
for mains wiring connection
USB extension lead
EAUSBEXT3WE
Metal wall box 435 or plastic
wall box 429R
2
Wall cavity
0.8Nm
Plasterboard
Mains cable
Brick wall

Variable field of view
3
Wall Cut Out
Wall cut out for standard installation only
Recommended Cut-Out Sizes to Fit Finished Products
Used on A B
MIN MAX MIN MAX
XL777X 70 92 50 56
LN777X 96 100 58 60
Min Wall Cavity (mm)
50XLV777X 74 92 52 56
Disclaimers
• This product must be installed by a licensed electrician.
• For indoor use only.
• Some references are suitable for installation in wall boxes or single brick applications.
• This product should not be installed in areas exposed to constant vibration, temperature fluctuations,
or areas of high humidity.
• This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it
should be discarded.
• This product has been designed to operate in ambient temperatures 5°C to 40°C.
• The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be
guaranteed.
• Electrical installations periodically receive transient over voltages. This product has been designed to minimise the effect
of such voltages on connected equipment. It may not give full protection for extreme over voltage transients such as those
resulting from a close lighting strike.
• This product has been designed to operate on a nominal supply voltage of 230 - 240V a.c. +/- 6%.
• Cable wiring of different voltage systems, such as Low Voltage and SELV cables, shall not share the same conduit
• This product must be installed and used as per these instructions.
• This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual
property remains the property of HPM Legrand in all cases
• HPM Legrand reserves the right to modify the specification of this product at any time.
Warranty
HPM Legrand will honour all statutory guarantees that you as a consumer are
entitled to rely upon under the Australian and New Zealand Consumer Laws against
a manufacturer including a guarantee that this product is of acceptable quality.
To make a claim under any statutory guarantee you should first contact the supplier,
or retailer from whom you purchased this product.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
HPM Legrand Australia
1300 369 777
www.hpm.com.au
HPM Legrand New Zealand
0800 476 009
www.hpm.co.nz
ABN: 31 000 102 661
LE08769AAB 10_2015 HPML0433