HPM 630/3, 630/3A, 630/3ABL Instruction Manual

Light Patrol
Cat. 630/3, 630/3A and 630/3ABL
Instruction Manual
2 Introduction
The Light Patrol Security Sensor incorporates a passive infrared detector that reacts instantly to body heat and movement. When it senses a person (at a distance of up to 12 metres) it acts as a switch to turn the lights on to which it is connected. When body heat and movement are no longer detected, the lights switch off after a period of time (adjustable). A built­in photocell deactivates the motion sensor during daylight hours if required.
The Light Patrol provides convenience, security and safety. Convenience for family and friends, lighting their way and making keys easier to locate. Security from intruders who are unexpectedly blasted by light, which usually has the effect of scaring them off. Safety by avoiding accidents caused by unseen obstacles.
1. Do not install when it is raining.
2. Be sure to switch off power source before installing.
3. Make sure the power wiring comes from a circuit protected by a suitable fuse or circuit breaker.
4. For outdoor installation, a location under eaves is preferable.
5. This unit must be installed by a licensed electrician according to local codes and regulations.
3 Features
4
Wheninstallingthesecuritysensorpay specialattentionto these points
Directed at swimming pools and ponds. The movement and reflections are likely to create nuisance switching.
Avoid, if possible, areas which are accessible to animals.
A position which is subject to drastic changesin
temperature.
In proximity of air conditioner, dryer or heater.
In direct sunlight.
5 Sensorlocationsto beavoided
Detection
Method:
Passive
infrared
Voltage
Supply:
230
-240V a.c. 50Hz
Standby
power:
0.7W
Max.
Lighting Load:
1200W
Incandescent
450VA
Fluorescent & CFL
Temperature:
-
10° C to 45°C
Detection
Range:
12m
at 24° C
Detection
Angle:
180
°
Adjustable
Angle:
180
° vertical
Auto
StopTime:
8
seconds ± 3 seconds (min.)
7
minutes ± 2 minutes (max.)
Lux
Level:
From
3 lux to daylight
Built
-in manual
override
function:
Cat 630/3
only
Weather
protected:
IP44
1 Specifications
1. Thought should be given to exactly what you would like the Light Patrol to do. This may influence your decision as to where to place it. If for instance you simply wish the lights to turn on when someone approaches your front door, the sensor should monitor the pathway leading to the front door. If however, you have a particular problem area where intruders can enter silently and undetected, you need the Light Patrol to monitor this area.
Added security can be achieved by linking the unit to both outdoor lights and lights or buzzer inside the house.
The Light Patrol monitors a 180° field of view. In practice, however, that scanning width may be toowide. If for instance, the neighbour’s driveway is creating nuisance switching (your unit is triggered by cars and people next door) the field of view may need to be restricted.
Four plastic blinkers are supplied. These can be inserted into the corner/s of the lens and will blind the sensor by approx. 13° for each blinker used. All four blinkers will reduce field of view to approx. 130°. These may be inserted one side or the other or shared – depending on the problem that you are attempting to overcome. (see figure 1)
2. Before installation make sure that the power is off
on that particular circuit. Remove the fuse or turn off the circuit breaker at the switchboard.
3. Choose a mounting position approximately 2 metres
above the area that you wish to monitor. (The unit may be mounted to a height of 4 metres.)
4. Remove the base cover and screw it to the wall or
eave through the two screw holes. If brick or concrete, wall plugs may be needed. Note: ‘Bottom’ is downward. Or, in the case of eave mounting, ‘bottom’ is closest to the wall (facing away from monitoring area).
5. Connect the Light Patrol to the power source
according to the ‘wiring instructions'. Then screw the main unit to the base cover.
6. Turn the power on. Start ‘walk test’(see TEST
MODE on page 3). Note: Up and down direction of the Light Patrol is
called the ‘tilting angle’. The bigger the tilting angle the shorter the detection distance – the most ideal tilt angle is between 0° and 10° (see figure 2.)
Variable field of view
Avoid straight-on monitoring as a person may not be detected walking straight ‘into’ the sensingarea.
Better to mount obliquely to the expected direction of approach so that the person walks ‘through’ the sensing area.
6 Installation
Figure 2
.
Figure 1
.
Walk Test
Turn the wall switch on. The light/s should turn on immediately and will remain on while the detection unit warms up, for approximately 40 seconds. It will then turn off. Do a walk test and the light should turn on. This confirms that the wiring is correct and that the light is operational. Walk through the coverage area and adjust the Light Patrol according to your needs. Wait for about 5 seconds between each walk test. You may need to insert plastic blinkers (see page 2).
Time adjustment
The time adjustment controls how long the light/s will stay on after movement is detected. This time varies between approximately 7 minutes (extreme clockwise) to approximately 8 seconds (extreme anti-clockwise).
Light adjustment
The light or lux adjustment controls the light level at which the Light Patrol will switch onwhenin Auto Mode. At the fully clockwise position the unit will operateand sense movement 24 hours aday. At thefully anti-clockwise setting the unit will operate only at night. To obtain the correct setting turn knob clockwiseuntil the light comes on at the desiredlux level.
Manual override (Cat 630/3 only)
There will be times when you wish the light to stay on regardless of motion. This may easily be achieved by turning the light off and on again within 1 -2 seconds. The light/s will now remain on until manually switched off. To return the Light Patrol to the Auto Mode turn the power ‘off’ for longer than 10 seconds and then switch back on. Cat 630/3A and 630/3ABL requires special wiring for manual override (see figure 5).
Cat 630/3A and 630/3ABL. Wiring to terminal block.
Cat 630/3A and 630/3ABL with by-pass switch. Protected position. Under eave if possible.
Turn the time control ( ) anti-clockwise and the light control ( ) clockwise to the test position (see figure 4.)
8 Test mode
Figure 4.
TESTposition
Figure 5.
TerminalBlock BaseCover
YourLamp
NEUTRAL(N) ACTIVE(L)
BOTTOM
Switch
RED
GASKET
WIRINGDIAGRAM
BROWN
BLUE
L N L
Wiring to terminal block. Cat 630/3 only. Protected position. Under eave if possible.
Figure 3.
Route cable from the light/s and cable from the power source to the terminal block.
Strip approximately 6 - 8mm insulation from the cables for insertion into the terminal block.
Run the power and light wires through the gasket hole and connect to the terminal block (see figure 3.)
Connect the neutral from power source to N. Connect the active from the power source to L. (Refer to terminal block for positioning on base cover).
Connect neutral from light/s to N. Connect active from the light/s to L. (see figure 3.)
Position terminal block and screw main unit of Light Patrol to the base cover.
A terminal is provided for terminating an earthing conductor. However, it is not compulsory to do this.
7 Wiring instructions
Warranty
Legrand Australia Pty Ltd warrants this product for a period of three years from the date of purchase. These goods come with guarantees that cannot be excluded under the Australian and New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired if the goods fails to be acceptable quality and the failure does not amount to a major failure. See the Warranty card enclosed with this product for further details.
Customer Service
For all Customer Service and Technical Support please call Monday to Friday during business hours.
Legrand Australia 1300 369 777 www.hpmlegrand.com.au
Legrand NewZealand
0800 476 009
www.hpmlegrand.co.nz
ABN: 31 000 102661
24490B
Trouble shooting suggestions
PROBLEM
LIKELY
CAUSE
POSSIBLE
SOLUTION
Light
will not
switch
on
when
there is
movement
in
detection
area.
1.
Power not available.
Check
connections, switches and fuse.
2.
Faulty globe.
Replace
globe.
3.
Incorrect wiring.
Recheck
all wiring.
4.
Controls incorrectly set.
Change
detection angle. Change light adjustment.
5.
Sensor positioned in wrong direction.
Change
position and direction of sensor.
Light
switches
on
for no
apparent reason.
1.
Air conditioner, heater, vents in proximity of sensor.
Reposition
and redirect sensor.
2.
Animals or birds.
Possibly unavoidable.
Redirect sensor.
3.
Interference on same circuit.
Check
for arcingswitches,replace noisyflouro tubesand/
or
starters. Consider connecting Light Patrol to different
circuit.
4.
Reflective objects in detection area.
Redirect
sensor and possibly reposition.
Light
will not
switch off after
set time
has
elapsed.
1.
Light is in manual mode (not in automatic). 630/3
only
Switch
light off for at least 10 seconds then switch
back
on to return it to auto mode.
2.
Wiring is incorrect.
Recheck
wiring.
3.
The unit has been damaged due to exceeding max
load,
use of an incompatible load type or failure of the
light
fitting (such as short circuit).
Identify
and fix the cause of the failure and replace the
unit with
a new one.
01/2019