HPE G2 Metered and Switched Power Distribution Units
Overview
New G2 features allow for greater management of power and environment in IT racks
HPE Enterprise Series G2 Metered and Switched PDUs are designed to work precisely with HPE Infrastructure and Compute
solutions
for your
stan
warranty
operational reliability for power distribution in your IT rac
A major concern for IT administrators and facility managers is their ability to quickly diagnose and service power related pr
in their IT racks
r simple and
quick access to IT equipment and power cables in the rear of the rack
HPE G2 Metered & Switched PDU features
alleviates the need to maintain older switch soluti
density outlet configurations that provide up to 48 power outlets
power in the rack while minimizing physical cabl
and exhaustive
in both the front and rear
of the rack.
All G2 Metered & Switched PDU
most HPE G2 PDUs
against vibration during shipping
Cords provide a safe and secure solution against the common issues that lead to power
HPE offers multiple Metered PDU form factors that promote efficient use of space in the rack and provide flexibility in how
, providing a highly accurate (billing grade accuracy) power distribution solution with outlet-level metering and switching
IT racks. Designed for use with HPE Standard, Advanced, and Enterprise racks (and compatible with other industry-
dard server racks), HPE G2 Metered and Switched PDUs guaranty a compatible fit and reliable operation backed by a 3 year
. HPE G2 Metered & Switched PDUs are also rated for operating temperatures up to 60°C, adding an increased level of
ks.
. G2 Metered & Switched PDU features such as color-coded outlets and low-profile form factors allow fo
.
are also directly focused on other pain points in the data center. 1Gb Ethernet
ons that have been traditionally required for PDU network connectivity. High-
in a full-height vertical form factor allow for simple access to
e requirements. Support for up to eight sensors per PDU provides a cost-effective
solution for monitoring the environmental elements (temperature, humidity, and leakage)
models feature support for HPE’s IEC Locking Power Cords, a new supported option available for
. The IEC Locking Power Cords provide secure cable retention to both the PDU and target device, protecting
and ensuring that cables are not dislodged during a service event. HPE’s IEC Locking Power
HPE Metered and Switched PDUs?
• HPE Foundation Care services purchased for server and storage products, such as extended warranties and premium
support services, extend to our PDU products free of charge when purchased together.
• HPE guarantees 100% compatibility between its Rack and Power Infrastructure products and its industry-standard
compute, storage, and networking solutions, backed with a 3-year warranty for all G2 Metered PDU models.
•
each PDU can be mounted and configured with cables.
-related downtime.
oblems

HPE G2 Metered and Switched Power Distribution Units
Models
200-208V Input, Single Phase, North America/Japan
HPE G2 Metered/Switched 4.9kVA/L6-30P 24A/208V Outlets (20) C13, (4) C19/Vertical NA/JP PDU
220-240V Input, Single Phase, International
HPE G2 Metered/Switched 7.3kVA/60309 3-Wire 32A/230V Outlets (20) C13, (4) C19/Vertical INTL PDU
200-208V Input, Three Phase, North America/Japan
HPE G2 Metered/Switched 3Ph 8.6kVA/L15-30P 24A/208V Outlets (18) C13, (6) C19/Vertical NA/JP PDU
HPE G2 Metered/Switched 3Ph 14.4kVA/CS8365C 40A/208V Outlets (12) C13, (12) C19/Vertical NA/JP PDU
HPE G2 Metered/Switched 3Ph 17.3kVA/60309 4-wire 48A/208V Out (12) C13, (12) C19/Vertical NA/JP PDU
HPE G2 Metered/Switched 3Ph 17.3kVA/60309 4-wire 48A/208V Out (36) C13, (12) C19/Vertical NA/JP PDU
220-240V Input, Three Phase, International
HPE G2 Metered/Switched 3Ph 11kVA/60309 5-Wire 16A/230V Out (18) C13, (6) C19/Vertical INTL PDU
HPE G2 Metered/Switched 3Ph 22kVA/60309 5-Wire 32A/230V Out (12) C13, (12) C19/Vertical INTL PDU
HPE G2 Metered/Switched 3Ph 22kVA/60309 5-Wire 32A/230V Out (36) C13, (12) C19/Vertical INTL PDU

HPE G2 Metered and Switched Power Distribution Units
Single-Phase Full-Height Model (P9S15A, P9S18A)
Three-Phase Full-Height Model (P9S21A, P9S24A)
Three-Phase High-Density Outlet Model (P9S23A, P9S25A)

HPE G2 Metered and Switched Power Distribution Units
Key Features
Power Metering
and Management
• All G2 HPE Metered & Switched PDUs meet IEC 62053-21, Class 1 standards for ±1% or better accuracy in
• OLED display provides local monitoring and alert indications
CLI, and third-party software applications supporting SNMP
• Designed specifically for use with HPE rack enclosures, but compatible with most 3rd party IT racks
• Integrated web-based user interface compatible with IPv4/IPv6 and SNMPv1/SNMPv3
• Multiple full-height vertical models with a range of outlet configurations
•
• Local and remote firmware updates
• Outlet-level on/off power switching that can be accessed locally and remotely
•
• Configurable alarm thresholds for both power and environmental monitoring
HPE G2 Metered & Switched PDUs support multiple features that are unique to HPE and help to provide the best user experience.
Inf
User’s Guide.
Rated for High
Operating
Temperatures
Increasing IT densities and escalating operating costs have created a need for rack infrastructure that can
operate reliably at higher operating temperatures
rated premium components and construction that support increased reliability levels at elevated temperatures
HPE G2 PDUs are rated for operation in temperatures up to 60°C (or 140°F) in the rear of the rack.
HPE G2 PDU models support optional IEC Locking Power Cords with an integrated locking technology on both
ends of the cable
multiple cable length options, and can be purchased in single or six
been included with each PDU model that supports either a C13 and/or C19 outlet.
High-Density
Vertical
PDU Models
High-density Vertical PDU models provide 48 outlets in a full-height (42U) form factor. This density is achieved
by placing the power receptacles on one side of the PDU and access to the circuit breakers on the opposite side
without significantly impacting the height (profile) of the PDU
information on high-density PDU models.
All HPE G2 PDU models now include color-coded outlets which are highly visible from the rear of the rack. The
color
configuring your IT equipment.
HPE is the first IT solutions company to standardize on 1Gb Ethernet for PDU network connectivity. This
eliminates the need to maintain older switching solutions needed for the 10/100 connectivity provided by most
other PDU manufacturers.
outlet-level power metering of:
o Amperage
o Voltage
o Wattage
Remote PDU management and power monitoring supported through integrated web-based user interface,
Low-profile form factors ensure integrity of rear-rack keep-out zone for IT maintenance
Color-coded receptacles to easily distinguish between the different load segments/phases
Integrated cord retention for all IEC C19 and C13 receptacles
Optional dual-locking power cords securing both power connections
Local and LDAP security with multiple access levels
Support for HTTP, HTTPS, and SSH protocols
ormation on these features is summarized below with additional information found online in HPE G2 Metered & Switched PDU
. HPE G2 PDUs have been designed with high temperature-
. HPE Locking Power Cord are available for both C13/14 and C19/20 power receptacles in
-pack kits. One IEC Locking Power Cord has
. See the Model Matrix section for more
.
-coding helps to easily and clearly identify outlets to simplify cabling and power phase balancing when

HPE G2 Metered and Switched Power Distribution Units
HPE G2 Metered & Switched PDU models include two environmental sensor ports (can be upgraded to six ports
with the addition of up to two
measurements
midity, water
leakage, and intrusion for each rack. Please review the Related Options section for a list of the options available.
Most vertical HPE G2 PDU models support mounting on the back and both sides of the PDU using an industrystandard button and keyhole mounting
capability that allows power cables to be configured
rack.
HPE PDU
Extension Ba
Options
HPE PDU extension bar options help expand the availability of power in the rear of the rack. Each extension bar
includes a locking input power cord that connects to the PDU and supports HPE’s new IEC Locking Power Cords
for C13/C14 and C19/C20 o
models
the rack when needed
the flexibility of placing access to power where it is
options are available to help you customize the outlet configurations you require
compatible with previous generation PDU models that offer C20 outlets (locking feature only supported on new
G2 PDU models). See the Related Options section for more information on G2 Extension Bar models.
HPE G2 Metered PDU models are supported with a 3-year warranty. Additionally, the HPE Foundation Care
Extension program provides additional support and services for your PDU models when purchased with HPE
servers, storage, and networking solutions at no additional charge
Additional
http://h17007.www1.hpe.com/us/en/enterprise/servers/warranty/index.aspx#.V-10xE3rvbq
G2 PDU Sensor Port Hubs) that can monitor and record up to eight sensor
. Multiple senor options are available providing the ability to monitor temperature, hu
system for easy drop-in installation. This provides a flexible mounting
with outlets facing toward the center, back, or front of the
r
utlets. HPE PDU extension bars can be added to Horizontal and Vertical PDU
, with available C19 outlets, to add additional power outlets and expand access to power in the back of
. Extension Bars mount directly to the frame of the rack in multiple locations allowing you
needed most (see figure above). Multiple extension bar
extension bars are also
.
information regarding worldwide limited warranty and technical support is available at:

HPE G2 Metered and Switched Power Distribution Units
Related Options
HPE G2 IEC C20 Input/(8) C13 Expansion Outlets/PDU Extension Bar Kit
HPE G2 IEC C20 Input/(4) C13 (2) C19 Expansion Outlets/PDU Extension Bar Kit
HPE G2 IEC C20 Input/(7) 5-20R Expansion Outlets/PDU Extension Bar Kit
NOTE: All kits include 2 extension bars with a locking C19 input power cord (1.8m).
HPE C13 - C14 WW 250V 10Amp 0.7m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 0.7m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 1.4m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 1.4m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 2m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 2m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 3m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 3m Black 6-pack Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 0.7m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 0.7m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 1.2m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 1.2m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2.5m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2.5m 6-pack Black Locking Power Cord
NOTE: HPE Locking Power Cords are only supported on either C13/14 or C19/20
outlets using HPE G2 PDUs.
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord
HP C13 - C14 WW 250V 10Amp 0.7m Jumper Cord
HP C13 - C14 WW 250V 10Amp 1.4m Jumper Cord
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord
HP C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord
HP C13 - C14 WW 250V 10Amp 2.5m Jumper Cord
HP C13 - C14 WW 250V 10Amp 3.0m Jumper Cord
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord
HP 200-250V 10A C15 to C14 .76m Jumper Cable
HP C13 - NEMA 5-15P US/CA 110V 10Amp 1.83m Power Cord
HP C13 - NEMA 5-15P TH/PH 250V 10Amp 1.83m Power Cord
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord
Cords

HPE G2 Metered and Switched Power Distribution Units
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord
HP C19 - NEMA 5-15P TH-PH 125V 15Amp 3.6m Power Cord
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord
HP C19 - NEMA 5-15 US/CA 125V 15Amp 3.6m Power Cord
HP C19 - NEMA L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord
HP C19 - NEMA 5-20P US/CA 125V 20Amp 4.5m Power Cord
HP 240 VAC 4.5M Unterminated End NA Power Cord
HPE Vertical PDU 10K G2 Mounting Kit
NOTE: This kit allows for vertical HPE G2 PDU models to be mounted in HPE 10000 G2
series racks and in the HPE Standard Series rack.
HPE G2 Metered PDUs include 2 physical sensor ports and can monitor and record up to eight sensor
measurements
user interface (GUI), or by third
supported API
software applications.
HPE G2 PDU Environmental Temperature Sensor
NOTE: Requires one input port and monitor/records one sensor measurement.
HPE G2 PDU Environmental Temperature and Humidity Sensor
NOTE: Requires one input port and monitors/records two sensor measurements.
HPE G2 PDU Environmental 3-Temperature and 1-Humidty Sensor
NOTE: Requires one input port and monitors/records four sensor measurements.
HPE G2 PDU Open/Close Door Sensor
NOTE:
HPE G2 PDU Leak Detection Sensor
NOTE:
covers up to six linear meters and can be expanded to cover up to thirty linear meters
with the addition of up to four HPE G2 PDU Leak Detection Sensor Extension Kits
(P9T08A).
HPE G2 PDU Sensor Port Hub
NOTE:
HPE G2 PDU Leak Detection Sensor Extension Kit
NOTE:
con
Detection Sensor to cover up to a maximum of thirty linear meters.
. Data collected by each sensor can be viewed and managed through the integrated graphical
-party applications that communicate through SNMP or through a Redfish
. Consult the HPE G2 Metered PDU User Guide for more information on use with third-party
Requires two input ports and monitors/records two sensor measurements.
Requires one input port and monitors/records one sensor measurement. Kit
This is an adapter that expands a single physical sensor port into three physical
Leak Detection Sensor (P9T04A) must be purchased separately to use in
junction with this kit. Up to four Extension Kits can be added to a single Leak

HPE G2 Metered and Switched Power Distribution Units
Matrix – Input Power
Mounting options for Vertical PDU models in HPE Advanced and Enterprise racks (1075mm depth)
Maximum PDUs per Side of Rack
* HPE high density model mounts on its side with outlets facing the back of the rack
NOTE: HPE G2 Advanced and Enterprise 1200mm deep racks include an extra set (2) of PDU trays in the rear of the rack
enabling support of up to 2x the number of PDUs listed above for 1075mm deep racks.
Model Matrix – Input Power
3-ph, 200-240V
3-ph, 346-415V
3-ph, 200-240V
3-ph, 346-415V
NOTE: All Input Circuit Ratings for NA/JP models have been de-rated according to NEC requirements.
Nominal Input Voltage Ratings used for calculating output power are as follows:
• 200 – 240V/346 – 415V: 230V
Model
Model Region
P9S20A INTL
3-ph, 346-415V
Vertical Height
Input Amps Circuit Breaker Input Plug Type
16A none IEC 16A, 3ph 10’
P9S24A INTL
P9S25A INTL
• 200 – 208V: 208V
• 220 – 240V: 230V
32A (6) 1-pole 16A IEC 32A, 3ph 10’
32A (6) 1-pole 16A IEC 32A, 3ph 10’

HPE G2 Metered and Switched Power Distribution Units
– Output Power
Model Matrix – Output Power
Model Region kVA
Output Voltage
Range
Output Receptacles
Options
Support Locking
Power Cord Options

HPE G2 Metered and Switched Power Distribution Units
PDU Plugs
Sample Plug Image
(color may vary by manufacturer)
Voltage Amps # Wires Plug Name
100-125 V
Single Phase
200-240 V
Single Phase
15 A 3 NEMA 5-15
20 A 3 NEMA 5-20
30 A 3 NEMA L5-30
20 A 3 IEC C20
30 A 3 NEMA L6-30
32 A 3 IEC 309 32A
50 A
CS8265C
63 A 3 IEC 309 63A
200 - 208 V
Three Phase
200 – 240 V
400 – 415 V
Three Phase
NA/JPN
INTL
30 A 5 NEMA L15-30
30 A 5 NEMA L21-30
50 A 4 CS8365C
60 A 4 IEC 309 60A
16 A 5 IEC 309 16 A
32 A 5 IEC 309 32 A