HPE G2 Switched Power Distribution Units
Overview
Setting new standards for reliable power distribution and metering
HPE G2 Switched PDUs are designed to work precisely with HPE Infrastructure and Compute solutions, providing a highly accurate
(billing grade accuracy) power distribution and metering so
with HPE Standard, Advanced, and Enterprise racks (and compatible with other industry
PDUs guaranty a compatible fit and reliable operation
operating temperatures up to 60°C
A major concern for IT administrators and facility managers is
in their IT racks
promote flexible power configuration in
utilize rack space while placing access to power where you need it most in the rack
such as color
the rear of the rack
HPE G2 Switched PDU features
to maintain old
sensors
humidity, and leakage)
HPE IEC Locking Power Cords are a new supported option available for most HPE G2 PDUs. The IEC Locking Power Cords provide
secure cable retention to both the PDU and target device
are not dislodged during a service event
issues that lead to power
HPE offers multiple Metered PDU form factors that promote efficient use of space in the rack and provide flexibility in how
each PDU can be mounted and configured with cables.
lution with outlet-level switching for your IT racks. Designed for use
-standard server racks), HPE G2 Switched
backed by a 3 year warranty. HPE G2 Switched PDUs are also rated for
, adding an increased level of operational reliability for power distribution in your IT racks.
their ability to quickly diagnose and service power related problems
. The HPE G2 PDU portfolio addresses this problem by, first, offering a range of models and mounting options that
IT racks. Vertical, Horizontal, and True 0U mounting, give you the flexibility to efficiently
. Serviceability is further enhanced with features
-coded outlets and low-profile form factors, allowing for simple and quick access to IT equipment and power cables in
.
are also directly focused on other pain points in the data center. 1Gb Ethernet alleviates the need
er switch solutions that have been traditionally required for PDU network connectivity. Support for up to eight
per PDU provides a cost-effective and exhaustive solution for monitoring the environmental elements (temperature,
in both the front and rear of the rack.
, protecting against vibration during shipping and ensuring that cables
. HPE’s IEC Locking Power Cords provide a safe and secure solution against the common
-related downtime.
HPE Switched PDUs?
• HPE Foundation Care services purchased for server and storage products, such as extended warranties and premium
support services, extend to our PDU products free of charge when purchased together.
• HPE guarantees 100% compatibility between its Rack and Power Infrastructure products and its industry-standard
compute, storage, and networking solutions, backed with a 3-year warranty for all G2 Metered PDU models.
•

HPE G2 Switched Power Distribution Units
Models
100-120V Input, Single Phase, North America/Japan
HPE G2 Switched 1.9kVA/IEC C20 Detachable 16A/120V Outlets (8) 5-20R/1U Horizontal NA/JP PDU
HPE G2 Switched 1.9kVA/IEC C20 Detachable 16A/120V Outlets (12) 5-20R/Vertical NA/JP PDU
HPE G2 Switched 2.8kVA/L5-30P 24A/120V Outlets (18) 5-20R/Vertical NA/JP PDU
HPE G2 Switched 2.8kVA/L5-30P 24A/120V Outlets (16) 5-20R/2U Horizontal NA/JP PDU
NOTE: Models P9S07A and P9S08A include a C19 to NEMA 5-15 detachable input power cord.
100-240V Input, Single Phase, Worldwide
HPE G2 Switched 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (8) C13/1U Horizontal WW PDU
HPE G2 Switched 3.6kVA/IEC C20 Detachable 16A/100-240V Outlets (12) C13, (4) C19/Vertical WW PDU
NOTE: Worldwide models do not include an input power cord. Please go to the Related Options section and select
the appropriate input power cord for your geographic location.
200-208V Input, Single Phase, North America/Japan
HPE G2 Switched 4.9kVA/L6-30P 24A/208V Outlets (12) C13, (4) C19/2U Horizontal NA/JP PDU
HPE G2 Switched 4.9kVA/L6-30P 24A/208V Outlets (20) C13, (4) C19/Vertical NA/JP PDU
220-240V Input, Single Phase, International
HPE G2 Switched 7.3kVA/60309 3-Wire 32A/230V Outlets (12) C13, (4) C19/2U Horizontal INTL PDU
HPE G2 Switched 7.3kVA/60309 3-Wire 32A/230V Outlets (20) C13, (4) C19/Vertical INTL PDU

HPE G2 Switched Power Distribution Units
1U Horizontal WW Model (P9S11A)
Vertical 120V Model (P9S08A)
WW Vertical Model (P9S12A)
Full-Height Vertical Models (P9S14A, P9S17A)
2U Horizontal Models (P9S13A, P9S16A)

HPE G2 Switched Power Distribution Units
Key Features
Power Metering
and Management
• All G2 HPE Switched PDUs meet IEC 62053-21, Class 1 standards for ±1% or better accuracy in power
• OLED display provides local monitoring and alert indications
CLI, and third-party software applications supporting SNMP
• Designed specifically for use with HPE rack enclosures, but compatible with most 3rd party IT racks
• Integrated web-based user interface compatible with IPv4/IPv6 and SNMPv1/SNMPv3
• Range of mounting options including vertical, 1U/2U horizontal, and True 0U (between the RETMA rails)
•
• Local and remote firmware updates
• Outlet-level on/off power switching that can be accessed locally and remotely
•
• Optional dual-locking power cords securing both power connections
HPE G2 Switched PDUs support multiple features that are unique to HPE and help to provide the best user experience. Information
on these features is summarized below with additional information found online in HPE G2 Metered PDU User’s Guide.
Rated for High
Operating
Temperatures
Increasing IT densities and escalating operating costs have created a need for rack infrastructure that can
operate reliably at higher operating temperatures
rated premium components and construction that support increased reliability levels at elevated temperatures
HPE G2 PDUs are rated for operation in temperatures up to 60°C (or 140°F) in the rear of the rack.
HPE G2 PDU models support optional IEC Locking Power Cords with an integrated locking technology on both
ends of the cable
multiple cable length options
been included with each PDU model that supports either a C13 and/or C19 outlet.
All HPE G2 PDU models now include color-coded outlets which are highly visible from the rear of the rack. The
color
configuring your IT equipment.
HPE is the first IT solutions company to standardize on 1Gb Ethernet for PDU network connectivity. This
eliminates the need to maintain older switching solutions needed for the 10/100 connectivity provided by most
other PDU manufacturers.
HPE G2 Switched PDU models include two environmental sensor ports (can be upgraded to six ports with the
addition of up to two
.
Multiple senor options are available providing the ability to monitor temperature, hu
intrusion for each rack. Please review the Related Options section for a list of the options available.
metering of:
o Amperage
o Voltage
o Wattage
Remote PDU management and power monitoring supported through integrated web-based user interface,
Low-profile PDU form factors ensure integrity of rear-rack keep-out zone for IT maintenance
Color-coded receptacles to easily distinguish between the different load segments/phases
Integrated cord retention on all IEC C19 and C13 receptacles (does not require any additional brackets)
Local and LDAP security with multiple access levels
Support for HTTP, HTTPS, SSH protocols
Configurable alarm thresholds for both power and environmental monitoring
. HPE G2 PDUs have been designed with high temperature-
. HPE Locking Power Cord are available for both C13/14 and C19/20 power receptacles in
.
, and can be purchased in single or six-pack kits. One IEC Locking Power Cord has
-coding helps to easily and clearly identify outlets to simplify cabling and power phase balancing when
G2 PDU Sensor Port Hubs) that can monitor and record up to eight sensor measurements
midity, water leakage, and

HPE G2 Switched Power Distribution Units
Most vertical HPE G2 PDU models support mounting on the back and both sides of the PDU using a button and
keyhole mounting system for easy drop
power cables to be configured toward the front, middle, or rear of the rack, allowing users to customize their
cable management strategy specifically for each rack.
HPE Horizontal PDUs have a unique design specifically for data center customers who want to maximize space
efficiencies in the rack.
installed in the 0U space between the RETMA rails on HPE Advanced and Enterprise Series racks
below).
HPE PDU
Extension Bar
Options
HPE PDU extension bar options help expand the availability of power in the rear of the rack. Each extension bar
includes a locking input power cord that connects to the PDU and supports HPE’s new IEC Locking Power Cords
for C13/C14 and C19/C20 outlets
models
the rack when needed. Extension Bars mount directly to the frame of the rack in multiple locations allowing you
the flexibil
options are available to help you customize the outlet configurations you require
compatible with previous generation PDU models that
C20 outlets (locking feature only supported on new
G2 PDU models). See the Related Options section for more information on G2 Extension Bar models.
HPE G2 Switched PDU models are supported with a 3-year warranty. Additionally, the HPE Foundation Care
Extension program provides additional support and services for your PDU models when purchased with HPE
servers, storage, and networking solutions at no additional charge
Additional information regarding worldwide limited warranty and
http://h17007.www1.hpe.com/us/en/enterprise/servers/warranty/index.aspx#.V-10xE3rvbq
All HPE 1U Horizontal PDUs can be installed in any U position in your rack or can be
-in installation. This provides a flexible mounting capability that allows
(see figure
. HPE PDU extension bars can be added to Horizontal and Vertical PDU
, with available C19 outlets, to add additional power outlets and expand access to power in the back of
ity of placing access to power where it is needed most (see figure above). Multiple extension bar
extension bars are also
offer
.
technical support is available at:

HPE G2 Switched Power Distribution Units
Related Options
HPE G2 IEC C20 Input/(8) C13 Expansion Outlets/PDU Extension Bar Kit
HPE G2 IEC C20 Input/(4) C13 (2) C19 Expansion Outlets/PDU Extension Bar Kit
HPE G2 IEC C20 Input/(7) 5-20R Expansion Outlets/PDU Extension Bar Kit
NOTE: All kits include 2 extension bars with a locking C19 input power cord (1.8m).
HPE C13 - C14 WW 250V 10Amp 0.7m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 0.7m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 1.4m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 1.4m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 2m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 2m Black 6-pack Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 3m Black Locking Power Cord
HPE C13 - C14 WW 250V 10Amp 3m Black 6-pack Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 0.7m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 0.7m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 1.2m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 1.2m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2m 6-pack Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2.5m Black Locking Power Cord
HPE C19 - C20 WW 250V 16Amp 2.5m 6-pack Black Locking Power Cord
NOTE: HPE Locking Power Cords are only supported on either C13/14 or C19/20 power
receptacles using HPE G2 PDUs.
HP C13 - C14 WW 250V 10A Gray 0.7m Jumper Cord
HP C13 - C14 WW 250V 10Amp 0.7m Jumper Cord
HP C13 - C14 WW 250V 10Amp 1.4m Jumper Cord
HP C13 - C14 WW 250V 10A Gray 1.37m Jumper Cord
HP C13 - C14 WW 250V 10Amp 1.4m 15 pc Jumper Cord
HP C13 - C14 WW 250V 10Amp 2.0m Jumper Cord
HP C13 - C14 WW 250V 10Amp Flint Gray 2.0m Jumper Cord
HP C13 - C14 WW 250V 10Amp 2.5m Jumper Cord
HP C13 - C14 WW 250V 10Amp 3.0m Jumper Cord
HP C13 - C14 WW 250V 10A Gray 3.0m Jumper Cord
HP C20 - C13 WW 250V 15Amp 2.0m Jumper Cord
HP C19 - C20 WW 250V 16Amp Flint Gray 1.20m Jumper Cord
HP C19 - C20 WW 250V 16Amp Flint Gray 2.0m Jumper Cord
HP C19 - C20 WW 250V 16Amp 2.5m Jumper Cord
HP 200-250V 10A C15 to C14 .76m Jumper Cable
Country-Specific
Power Cords
HP C13 - NEMA 5-15P US/CA 110V 10Amp 1.83m Power Cord
HP C13 - NEMA 5-15P TH/PH 250V 10Amp 1.83m Power Cord
HP C19 - CEE-VII EU 250V 16Amp 3.6m Power Cord
HP C19 - AS3112-3 AU/NZ 250V 15Amp 3.6m Power Cord
HP C19 - SABS-164 ZA 250V 16Amp 3.6m Power Cord
HP C19 - CEI-23-50 IT/CL 250V 16Amp 3.6m Power Cord
HP C19 - IEC-309 DK/SE/AR 250V 16Amp 3.6m Power Cord

HPE G2 Switched Power Distribution Units
HP C19 - IS-1293 IN/PK/BD 250V 16Amp 2.5m Power Cord
HP C19 - ISI-32 IL 250V 16Amp 2.5m Power Cord
HP C19 - GB-1002 CN 250V 16Amp 2.5m Power Cord
HP C19 - NEMA 5-15P TH-PH 125V 15Amp 3.6m Power Cord
HP C19 - NBR-14136 BR 250V 16Amp 2.5m Power Cord
HP C19 - NEMA 5-15 US/CA 125V 15Amp 3.6m Power Cord
HP C19 - NEMA L6-20P NA/JP 250V 20Amp High Voltage 3.6m Power Cord
HP C19 - BS-1363/A UK/HK/SG 250V 13Amp 3.6m Power Cord
HP C19 - NEMA 5-20P US/CA 125V 20Amp 4.5m Power Cord
HP 240 VAC 4.5M Unterminated End NA Power Cord
HPE Vertical PDU 10K G2 Mounting Kit
NOTE: This kit allows for vertical HPE G2 PDU models to be mounted in HPE 10000 G2 series racks and
in the HPE Standard Series rack.
HPE G2 Metered PDUs include 2 physical sensor ports and can monitor and record up to eight sensor
measurements. Data collected by each sensor can be viewed and managed through the integrated graphical
user interface (GUI), or by third
supported API
software applications.
HPE G2 PDU Environmental Temperature Sensor
NOTE: Requires one input port and monitor/records one sensor measurement.
HPE G2 PDU Environmental Temperature and Humidity Sensor
NOTE: Requires one input port and monitors/records two sensor measurements.
HPE G2 PDU Environmental 3-Temperature and 1-Humidty Sensor
NOTE: Requires one input port and monitors/records four sensor measurements.
HPE G2 PDU Open/Close Door Sensor
NOTE:
HPE G2 PDU Leak Detection Sensor
NOTE:
covers up to six linear meters and can be expanded to cover up to thirty linear meters
with the addition of up to four HPE G2 PDU Leak Detection Sensor Extension Kits
(P9T08A).
HPE G2 PDU Sensor Port Hub
NOTE:
HPE G2 PDU Leak Detection Sensor Extension Kit
NOTE:
conjunction with this kit. Up to four Extensi
Detection Sensor to cover up to a maximum of thirty linear meters.
rackets
-party applications that communicate through SNMP or through a Redfish
. Consult the HPE G2 Metered PDU User Guide for more information on use with third-party
Requires two input ports and monitors/records two sensor measurements.
Requires one input port and monitors/records one sensor measurement. Kit
This is an adapter that expands a single physical sensor port into three physical
Leak Detection Sensor (P9T04A) must be purchased separately to use in
on Kits can be added to a single Leak

HPE G2 Switched Power Distribution Units
– Input Power
Mounting options for Horizontal 1U and 2U PDU models
Mounting options for Vertical PDU models in HPE Advanced and Enterprise racks (1075mm depth)
Maximum PDUs per Side of Rack
NOTE: HPE G2 Advanced and Enterprise 1200mm deep racks include an extra set (2) of PDU trays in the rear of the rack
enabling support of up to 2x the number of PDUs listed above for 1075mm deep racks.
Model Matrix – Input Power
*WW models require the selection of a regional power cord. Refer to Related Options section for HPE power cord options.
NOTE: All Input Circuit Ratings for NA/JP models have been de-rated according to NEC requirements.
Nominal Input Voltage Ratings used for calculating output power are as follows:
Model
P9S13A
Model
Model Region
(inches)
15.9
(lbs.)
U Height
Vertical Height
True 0U Mounting
• 100 – 125V: 120V
• 200 – 208V: 208V
• 100 – 240V: 230V
• 220 – 240V: 230V
12’ (detachable)

HPE G2 Switched Power Distribution Units
– Output Power
Model Matrix – Output Power
NOTE: For more information on Extension Bar and Power Cord options, please see the Related Options section.
Model Region
Nominal
Power (kVA)
Output Voltage
Range
Output
Receptacles
Support Extension
Bar Options
Support Locking Power
Cord Options

HPE G2 Switched Power Distribution Units
PDU Plugs
Sample Plug Image
(color may vary by manufacturer)
Voltage Amps # Wires Plug Name
100-125 V
Single Phase
200-240 V
Single Phase
15 A 3 NEMA 5-15
20 A 3 NEMA 5-20
30 A 3 NEMA L5-30
20 A 3 IEC C20
30 A 3 NEMA L6-30
32 A 3 IEC 309 32A
50 A
CS8265C
63 A 3 IEC 309 63A
200 - 208 V
Three Phase
200 – 240 V
400 – 415 V
Three Phase
NA/JPN
INTL
30 A 5 NEMA L15-30
30 A 5 NEMA L21-30
50 A 4 CS8365C
60 A 4 IEC 309 60A
16 A 5 IEC 309 16 A
32 A 5 IEC 309 32 A