HPE FlexNetwork 5940 48p 10GbE SFP/SFP+ and 6p 40/100GbE QSFP28 with 2 Fans 2 PS Switch Bundle
JH684A
HPE FlexNetwork 5940 48p 10GBaseT and 6p 40/100GbE QSFP28 with 2 Fans 2 PS Switch Bundle
JH685A
HPE FlexNetwork 5940 32-port 40GbE QSFP+ with 2 Fans 2 Power Supply Switch Bundle
JH686A
HPE FlexNetwork 5940 2-slot Chassis with 2 Fans 2 Power Supply Bundle
JH691A
HPE FlexNetwork 5940 4-slot Chassis with 2 Fans 4 Power Supply Bundle
JH692A
Key features
• VXLAN L2 and L3 and EVPN support for virtualized environments
Product overview
The HPE FlexFabric 5940 Switch Series is a family of high performance and low-latency 10GbE, 40GbE top-of-rack (ToR) data
center switches. The switch series include also 100G uplink technology and also a 2-slot and 4-slot modular form factor providing
• OpenFlow support for investment protection and SDN environments
• High-density 10GbE, 40GbE with 40G or 100G uplink and modular for spine-and–leaf deployments
• Unify management of virtual and physical network with VEPA and IMC
• Data center convergence and resiliency with SPB, ISSU, DCB, FC/FCoE, IRF, and TRILL
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
2
ultimate flexibility for an ever-changing Data Center requirements. This entire series is part of the Hewlett Packard Enterprise
FlexFabric data center solution, which is a cornerstone of the FlexNetwork architecture.
The FlexFabric
data centers, or at the core layer of medium
With the increase pace of deploying virtualized applications, adopting softwar
server traffic,
many data centers now require spine and ToR switch innovations that will meet their requirements. The HPE FlexFabric 5940 is
optimized to meet the increasing requirements for higher
traffic, the capability to handle virtual environments, and low-latency.
Features and benefits
Quality of Service (QoS)
os architecture with VOQs and large buffers with the flexibility and scalability for
Data center optimized
through and nonblocking architecture delivers low latency (~1 microsecond for 10GbE) for very demanding enterprise
monitoring, and restart; the OS also allows individual software modules to be upgraded for higher availability and supports
provides support for T11 standards-compliant FC-BB-5 Fibre Channel over Ethernet (FCoE), including FCoE initialization
5940 Switch Series is ideally suited for deployment at the aggregation or server access layer of large enterprise
− Packet filtering and remarking: Packet filtering at L2 (Layer 2) through L4 (Layer 4); flow classification based
-sized enterprises.
e-defined networking, and the server-to-
-performance server connectivity, convergence of Ethernet and storage
Configurable Buffer, Time range, Queue Shaping, CAR with 8kbps granularity.
on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6)
address, port, protocol, and VLAN.
provides nonblocking, lossless Cl
future growth
• Flexible high port density
5940 switch enables customers to scale their server-edge 10/40/100 GbE ToR deployments to new heights with highdensity 48 x 10 GbE ports with 6 ports of 40G, 48 x 10 GbE ports with 6 ports of 100G and 32 x 40 GbE delivered in a
1RU design; the 5940 32 ports of 40G switch can also be configured as a 72 x 10 GbE port device by using a 40G-to-10
GbE splitter cable that turns each 40 GbE port into four 10-GbE ports. The 48 ports models comes in SFP+ or BASE-T
• High-performance switching
cutapplications; the switch delivers high-performance switching capacity and wire-speed packet forwarding
• Higher scalability
Hewlett Packard Enterprise Intelligent Resilient Fabric (IRF) technology simplifies the architecture of server access
networks; up to nine HPE 5940 switches can be combined to deliver unmatched scalability of virtualized access layer
switches and flatter two-tier networks using IRF, which reduces cost and complexity
• Advanced modular operating system
Comware v7 software's modular design and multiple processes bring native high stability, independent process
enhanced serviceability functions like hitless software upgrades
• Reversible airflow
enhanced for data center hot-cold aisle deployment with reversible airflow—for either front-to-back or back-to-front
airflow
• Redundant fans and power supplies
Internal redundant and hot-pluggable power supplies and dual fan trays enhance reliability and availability
• Lower OPEX and greener data center
provide reversible airflow and advanced chassis power management
• Data Center Bridging (DCB) protocols
provides support for IEEE 802.1Qbb Priority Flow Control (PFC), Data Center Bridging Exchange (DCBX), IEEE 802.1Qaz
Enhanced Transmission Selection (ETS), Explicit Congestion Notification (ECN) for converged FCoE, iSCSI and RoCE
environments
• FCoE support
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
3
protocol (FIP), FCP, Fiber Channel enhanced port types VE, TE and VF, NPV, NPIV, fabric name server, RSCN, login
performance remote backup
Manageability
cased access control (RBAC) provides
multiple levels of access; configuration rollback and multiple configurations on the flash provide ease of operation; remote
Resiliency and high
allows groups of two routers to back each other up dynamically to create highly available routed environments
• Jumbo frames
• VXLAN hardware support
• Dynamic VXLAN configuration
• EVPN
• Full-featured console
• Troubleshooting
• Multiple configuration files
• SNMP v1, v2c and v3
• Out-of-band interface
• Remote configuration and management
services, and name-server zoning, per-VSAN fabric services, FSPF, standard zoning and fiber channel ping
with frame sizes of up to 10,000 bytes on Gigabit Ethernet and 10-Gigabit ports, allows highand disaster-recovery services to be enabled
VXLAN Layer 2 and Layer 3 gateway support for up to 4k tunnels
OVSDB & ML2 support for dynamic VXLAN configuration
Control plane protocol for VXLAN based on industry standards. It enables Layer-2 and Layer-3 control-plane learning of
end-host reachability information, enabling organizations to scale their VXLAN infrastructure better. Integration with
Openstack Neutron plugin for overlay automation/orchestration
provides complete control of the switch with a familiar CLI
− Ingress and egress port monitoring: enable network problem solving
− Traceroute and ping: enable testing of network connectivity
allow multiple configuration files to be stored to a flash image
facilitate centralized discovery, monitoring, and secure management of networking devices
isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
delivered through a secure command-line interface (CLI) over Telnet and SSH; role-
visibility is provided with sFlow and SNMP v1/v2/v3, and is fully supported in HPE Intelligent Management Center (IMC)
• ISSU and hot patching
In Services Software Upgrade (ISSU) provides hitless software upgrades and hitless patching of the modular operating
system
• Autoconfiguration
provides automatic configuration via DHCP autoconfiguration
• NTP, SNTP
synchronizes timekeeping among distributed time servers and clients; support for network time protocol (NTP), secure
network time protocol (SNTP)
• IRF technology
enables an Hewlett Packard Enterprise FlexFabric to deliver resilient, scalable, and secured data center networks for
physical and virtualized environments; groups up to nine HPE 5940 switches in an IRF configuration, allowing them to be
configured and managed as a single switch with a single IP address; simplifies ToR deployment and management,
reducing data center deployment and operating expenses
• IEEE 802.1w Rapid Convergence Spanning Tree Protocol
increases network uptime through faster recovery from failed links
• IEEE 802.1s Multiple Spanning Tree
provides high link availability in multiple VLAN environments by allowing multiple spanning trees
• Virtual Router Redundancy Protocol (VRRP)
availability
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
4
• Hitless patch upgrades
Layer 2 switching
pport for LACP, LACP Local Forwarding First,
optimization of
Layer 3 services
es the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection
Layer 3 routing
allow quick failover of router ports
allows patches and new service features to be installed without restarting the equipment, increasing network uptime and
facilitating maintenance
Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Device Link Detection Protocol (DLDP)
monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STPbased networks
• Graceful restart
allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown and
significantly reduces convergence times upon recovery; supports OSPF, BGP, and IS-IS
• MAC-based VLAN
provides granular control and security; uses RADIUS to map a MAC address/user to specific VLANs
• Address Resolution Protocol (ARP)
supports static, dynamic, and reverse ARP and ARP proxy
• IEEE 802.3x Flow Control
provides intelligent congestion management via PAUSE frames
• Ethernet Link Aggregation
provides IEEE 802.3ad Link Aggregation of up to 128 groups of 32 ports; su
and LACP Short-time provides a fast, resilient environment that is ideal for the data center
provides support for 4,096 VLANs based on port, MAC address, IPv4 subnet, protocol, and guest VLAN; supports VLAN
mapping
• IGMP support
provides support for IGMP Snooping, Fast-Leave, and Group-Policy; IPv6 IGMP Snooping provides Layer 2
multicast traffic
•DHCP support at Layer 2
provides full DHCP Snooping support for DHCP Snooping Option 82, DHCP Relay Option 82, DHCP Snooping trust, and
DHCP Snooping item backup
• Address Resolution Protocol (ARP)
• Dynamic Host Configuration Protocol (DHCP)
• Operations, administration and maintenance (OAM) support
• Virtual Router Redundancy Protocol (VRRP) and VRRP Extended
determin
of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a
Layer 2 network
simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation
across subnets
provides support for Connectivity Fault Management (IEEE 802.1AG) and Ethernet in the First Mile (IEEE 802.3AH);
provides additional monitoring that can be used for fast fault detection and recovery
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
5
• Policy-based routing
IS routing and extended
Additional in
Management
− File copy: allows users to copy switch files to and from a USB flash drive
makes routing decisions based on policies set by the network administrator
• Equal-Cost Multipath (ECMP)
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
• Layer 3 IPv4 routing
provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, BGP, and IS-IS
• Open shortest path first (OSPF)
delivers faster convergence; uses this link-state routing Interior Gateway Protocol (IGP), which supports ECMP, NSSA, and
MD5 authentication for increased security and graceful restart for faster failure recovery
• Border Gateway Protocol 4 (BGP-4)
delivers an implementation of the Exterior Gateway Protocol (EGP) utilizing path vectors; uses TCP for enhanced
reliability for the route discovery process; reduces bandwidth consumption by advertising only incremental updates;
supports extensive policies for increased flexibility; scales to very large networks
• Intermediate system to intermediate system (IS-IS)
uses a path vector Interior Gateway Protocol (IGP), which is defined by the ISO organization for ISby IETF RFC 1195 to operate in both TCP/IP and the OSI reference model (Integrated IS-IS)
• Static IPv6 routing
provides simple manually configured IPv6 routing
• Dual IP stack
maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network to an IPv6-only network
design
• Routing Information Protocol next generation (RIPng)
extends RIPv2 to support IPv6 addressing
• OSPFv3
provides OSPF support for IPv6
• BGP+
extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
• IS-IS for IPv6
extends IS-IS to support IPv6 addressing
• IPv6 tunneling
allows IPv6 packets to traverse IPv4-only networks by encapsulating the IPv6 packet into a standard IPv4 packet;
supports manually configured, 6to4, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunnels; is an
important element for the transition from IPv4 to IPv6
• Policy routing
allows custom filters for increased performance and security; supports ACLs, IP prefix, AS paths, community lists, and
aggregate policies
• Bidirectional Forwarding Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Multicast Routing PIM Dense and Sparse modes
provides robust support of multicast protocols
• Layer 3 IPv6 routing
provides routing of IPv6 at media speed; supports static routing, RIPng, OSPFv3, BGP4+ for IPv6, and IS-ISv6
• Green IT and power
• USB support
formation
improves energy efficiency through the use of the latest advances in silicon development; shuts off unused ports and
utilizes variable-speed fans, reducing energy costs
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
6
• Port mirroring
Security
Convergence
enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
• Remote configuration and management
is available through a CLI
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
advertises and receives management information from adjacent devices on a network, facilitating easy mapping by
network management applications
• sFlow (RFC 3176)
provides scalable ASIC-based wirespeed network monitoring and accounting with no impact on network performance; this
allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and
real-time network monitoring purposes
• Command authorization
leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; an audit trail
documents activity
• Dual flash images
provides independent primary and secondary operating system files for backup while upgrading
• Command-line interface (CLI)
provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console; provides direct real-time
session visibility
• Logging
provides local and remote logging of events via SNMP (v2c and v3) and syslog; provides log throttling and log filtering to
reduce the number of log events generated
• Management interface control
provides management access through a modem port and terminal interface, as well as in-band and out-of-band Ethernet
ports; provides access through terminal interface, Telnet, or secure shell (SSH)
• Industry-standard CLI with a hierarchical structure
reduces training time and expenses, and increases productivity in multivendor installations
• Management security
restricts access to critical configuration commands; offers multiple privilege levels with password protection; ACLs provide
Telnet and SNMP access; local and remote syslog capabilities allow logging of all access
• Information center
provides a central repository for system and network information; aggregates all logs, traps, and debugging information
generated by the system and maintains them in order of severity; outputs the network information to multiple channels
based on user-defined rules
• Network management
HPE IMC centrally configures, updates, monitors, and troubleshoots
• Remote intelligent mirroring
mirrors ingress/egress ACL-selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the
network
• Access control lists (ACLs)
• RADIUS/TACACS+
• Secure shell
• IEEE 802.1X and RADIUS network logins
• Port security
provide IP Layer 3 filtering based on source/destination IP address/subnet and source/destination TCP/UDP port number
eases switch management security administration by using a password authentication server
encrypts all transmitted data for secure remote CLI access over IP networks
controls port-based access for authentication and accountability
allows access only to specified MAC addresses, which can be learned or specified by the administrator
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Overview
7
•LLDP-MED (Media Endpoint Discovery)
defines a standard extension of LLDP that stores values for parameters such as QoS and VLAN to configure automatically
Warranty and support
; for details on the software releases
HPE Recommended Options have the best performance, value and availability.
Recommended Options
workloads and market segments.
nd security experience, Recommended Options
provide the best fit with timely availability.
Extended Options
requiring the utmost in performance or value.
Options represent great value and performance but
network devices such as IP phones
•1-year warranty
see http://www.hpe.com/networking/warrantysummary
product purchase.
• Software releases
to find software for your product, refer to http://www.hpe.com/networking/support
available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary
for warranty and support information included with your
have been selected by Hewlett Packard Enterprise experts to provide the right technology for a range of
Fully integrated into the ProLiant management a
View the list for your region.
provide an extended catalog of products tailored for customers in specific markets or with specific workloads,
Fully integrated into the ProLiant management and security experience, Extended
typically have a longer lead-time.
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
8
Build To Order
Shippable solution.
Standard Switch Enclosures
HPE FlexFabric 5940 32QSFP+ Switch
JH396A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 2-slot Switch
JH397A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 4-slot Switch
JH398A
•
• 2U - Height
HPE FlexFabric 5940 2-slot 2QSFP+ Front-to-Back AC Bundle
JQ041A
•
• 1U - Height
See Configuration
PDU Cable NA/MEX/TW/JP
JQ041A#B2B
•
PDU Cable ROW
JQ041A#B2C
• C15 PDU Jumper Cord (ROW)
High Volt Power Supply to Wall Power Cord
JQ041A#B2E
• NEMA L6-20P Cord (NA/MEX/JP/TW)
No Power Cord
JQ041A#AC3
• No Localized Power Cord Selected
HPE FlexFabric 5940 2-slot 2QSFP+ Back-to-Front AC Bundle
JQ042A
•
• Includes 2 Power Supply (JC680A)
See Configuration
: BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-
32 QSFP+ ports (min=0 \ max=32)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
2 QSFP+ ports (min=0 \ max=2)
• 2 port expansion module slots
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
NOTE:2
NOTE:2
4 port expansion module slots
• Must select min 2 Power Supply
• Must select min 2 Fan Trays
2 QSFP+ ports (min=0 \ max=2)
• 2 port expansion module slots
• Includes 2 Power Supply (JC680A)
• Includes 2 Fan Trays (JG552A)
C15 PDU Jumper Cord (NA/MEX/TW/JP)
NOTE:2
2 QSFP+ ports (min=0 \ max=2)
• 2 port expansion module slots
NOTE:2
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
9
•
• 1U - Height
PDU Cable NA/MEX/TW/JP
JQ042A#B2B
• C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JQ042A#B2C
• C15 PDU Jumper Cord (ROW)
High Volt Power Supply to Wall Power Cord
JQ042A#B2E
• NEMA L6-20P Cord (NA/MEX/JP/TW)
No Power Cord
JQ042A#AC3
•
HPE FlexFabric 5940 4-slot Front-to-Back AC Bundle
JQ043A
•
• 2U - Height
PDU Cable NA/MEX/TW/JP
JQ043A#B2B
• C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JQ043A#B2C
• C15 PDU Jumper Cord (ROW)
High Volt Power Supply to Wall Power Cord
JQ043A#B2E
• NEMA L6-20P Cord (NA/MEX/JP/TW)
No Power Cord
JQ043A#AC3
• No Localized Power Cord Selected
HPE FlexFabric 5940 4-slot Back-to-Front AC Bundle
JQ044A
•
• 2U - Height
PDU Cable NA/MEX/TW/JP
JQ044A#B2B
• C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JQ044A#B2C
• C15 PDU Jumper Cord (ROW)
High Volt Power Supply to Wall Power Cord
JQ044A#B2E
• NEMA L6-20P Cord (NA/MEX/JP/TW)
No Power Cord
JQ044A#AC3
Includes 2 Fan Trays (JG553A)
No Localized Power Cord Selected
4 port expansion module slots
• Includes 4 Power Supply (JC680A)
• Includes 2 Fan Trays (JH186A)
4 port expansion module slots
• Includes 4 Power Supply (JC680A)
• Includes 2 Fan Trays (JH185A)
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
10
• No Localized Power Cord Selected
HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch
JH395A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 48XGT 6QSFP+ Switch
JH394A
•
•
See Configuration
HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch
JH390A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 48XGT 6QSFP28 Switch
JH391A
•
• 1U - Height
See Configuration
Configuration Rules
Note 1
The following SFP+ Transceivers install into this Switch:
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC SR Data Center Transceiver
JL437A
HPE X130 10G SFP+ LC LR Data Center Transceiver
JL439A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
JG331A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 3
The following QSFP28 Transceivers install into this switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver
JL274A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver
JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable
JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable
JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable
JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver
JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver
JH673A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable
JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable
JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable
JL273A
Note 4
If this switch is configured for an NFV solution(Q0F04A - HPE NFV System V1.3 3Par Storage Block), default no
less than the quantities specified below for the following components:
Qty 2
Qty 2
Qty 4
Qty 1 - JG326A (min 1)
Note 5
The following SFP Transceivers install into this Switch:
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 6
Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) . (See Localization Menu)
REMARK: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be
option on the Switches/Routers.
Note 7
The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver
JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver
JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 8
The following 100G Transceivers install into this Switch's QSFP28 Ports: (Use #0D1 or #B01 if switch is CTO) - if
applicable
JH419A - HPE X150 100G QSFP28 SWDM4 100m MM XCVR
Remarks:
Drop down under power supply should offer the following options and results:
Switch/Router to PDU Power Cord
#B2B in NA, Mexico, Taiwan, and Japan or #B2C ROW. (Watson Default B2B or
B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord
Hi
Taiwan, and Japan)
No Power Cord
OCA Only Model Selection Form
HPE Offering > DataCenter Networking > FlexFabric Switches
5940 DCN Switch Series
Box Level Integration CTO Models
CTO Solution Sku
HPE 59xx CTO Switch Solution
JG505A
See Configuration
Configuration Rules
Note 1
Clic UNB - Min/Max 1 CTO switch per SSP.
CTO Switch Chassis
HPE FlexFabric 5940 32QSFP+ Switch
JH396A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 2-slot Switch
JH397A
•
• 1U - Height
See Configuration
-
- Localized Option (Watson Default for BTO and Box Level CTO)
gh Volt Switch/Router/Power Supply to Wall Power Cord - #B2E Option. (Offered only in North America, Mexico,
- #AC3 Option
-
- Access:
• SSP trigger sku
32 QSFP+ ports (min=0 \ max=32)
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
2 QSFP+ ports (min=0 \ max=2)
• 2 port expansion module slots
• Must select min 1 Power Supply
• Must select min 2 Fan Trays
NOTE:1
NOTE:2, 4
NOTE:2, 4
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
13
HPE FlexFabric 5940 4-slot Switch
JH398A
•
• 2U - Height
See Configuration
HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch
JH395A
•
•
See Configuration
HPE FlexFabric 5940 48XGT 6QSFP+ Switch
JH394A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch
JH390A
•
• 1U - Height
See Configuration
HPE FlexFabric 5940 48XGT 6QSFP28 Switch
JH391A
•
• 1U - Height
See Configuration
Configuration Rules
Note 1
The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if applicable
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC SR Data Center Transceiver
JL437A
HPE X130 10G SFP+ LC LR Data Center Transceiver
JL439A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
JG331A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 3
The following QSFP28 Transceivers install into this switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver
JL274A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver
JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable
JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable
JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable
JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver
JH420A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable
JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable
JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable
JL273A
Note 4
If the Switch Chassis is to be Box Level Factory Integrated (CTO), Then the #0D1 is required on the Switch Chassis
and integrated to the JG505A - HPE 59xx CTO Switch Solution. (Min 1/Max 1 Router per SSP)
Note 5
If this switch is configured for an NFV solution(Q0F04A - HPE NFV System V1.3 3Par Storage Block), default no
less than the quantities specified below for the following components:
Qty 2
Qty 2
Qty 4
Qty 1 - JG326A (min 1)
Note 6
The following SFP Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if applicable
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 7
The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if
switch is CTO) - if applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver
JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver
JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
JG331A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 3
The following QSFP28 Transceivers install into this switch:
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver
JL274A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver
JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable
JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable
JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable
JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver
JH420A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable
JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable
JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable
JL273A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver
JH673A
Note 4
If HPE CTO Switch Chassis is selected for Rack Level Integration, Then the Switch needs to integrate (with #0D1) to
the Rack.
Note 5
If this switch is configured for an NFV solution(Q0F04A - HPE NFV System V1.3 3Par Storage Block), default no
less than the quantities
Qty 2
Qty 2
Qty 4
Qty 1 - JG326A (min 1)
Note 6
The following SFP Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) - if applicable
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
specified below for the following components:
- JG553A (min 2)
- JC680A (min 2)
- JD092B (min 4)
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
19
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 7
The following 40G Transceivers install into this Module's QSFP+ Ports: (Use #0D1 or #B01 if switch is CTO) - if
applicable
HPE X140 40G QSFP+ LC LR4 SM 10km 1310nm Transceiver
JG661A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
JL251A
HPE X140 40G QSFP+ MPO SR4 Transceiver
JG325B
HPE X140 40G QSFP+ LC ER4 40km SM Transceiver
JL306A
HPE X140 40G QSFP+ MPO MM 850nm CSR4 300m Transceiver
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 8
The following 100G Transceivers install into this Switch's QSFP28 Ports: (Use #0D1 or #B01 if switch is CTO) - if
applicable
JH419A - HPE X150 100G QSFP28 SWDM4 100m MM XCVR
Remarks
Drop down under power supply should offer the following options and results:
Switch/Router to PDU Power Cord
#B2B in NA, Mexico, Taiwan, and Japan or #B2C ROW. (Watson Default B2B or
B2C for Rack
Switch/Router/Power Supply to Wall Power Cord
High Volt Switch/Router/Power Supply to Wall Power Cord
Taiwan, and Japan)
No Power Cord - #AC3 Option
Clic UNB - If an option is ordered with #0D1/#B01, then the switch must have #0D1 option.
Enter the following menu selections as integrated to the CTO Model X server above if order is factory built.
Switch Options
(JH397A, JQ041A, JQ042A) System (std 0 // max 2) User Selection (min 0 // max 2)
(JH398A, JQ043A, JQ044A) System (std 0 // max 4) User Selection (min 0 // max 4)
OCA Blue NOTE:
Fibre channel support is 8Gb/4Gb/2Gb on any of the 24
Module. Note that a maximum of 8Gb FC is supported regardless of the FC optics used.
Note 14
The following SFP Transceivers install into this Module: (Use #0D1 or #B01 if switch is CTO) if applicable
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 15
The following SFP+ Transceivers install into this Switch: (Use #0D1 or #B01 if switch is CTO) if applicable
HPE X130 10G SFP+ LC LH 80km Transceiver
JG915A
HPE X130 10G SFP+ LC ER 40km Transceiver
JG234A
converged ports of the JH184A
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
23
Transceivers
SFP Transceivers
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
NOTE: Only supported on PHY switch ports
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
NOTE: Only supported on PHY switch ports
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Remarks
:
OCA Blue Note - The SFP Transceivers(JD061A, JD062A) are only supported in ports 1-8 for the JH390A Switch
and ports 1-16 for the JH395A Switch.
SFP+ Transceivers
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC SR DC XCVR
JL437A
HPE X130 10G SFP+ LC LR DC XCVR
JL439A
HPE X130 10G SFP+ LC LH 80km Transceiver
JG915A
HPE X130 10G SFP+ LC ER 40km XCVR
JG234A
HPE X240 10G SFP+ SFP+ 0.65m DAC Cable
JD095C
HPE X240 10G SFP+ SFP+ 1.2m DAC Cable
JD096C
HPE X240 10G SFP+ SFP+ 3m DAC Cable
JD097C
HPE X240 10G SFP+ SFP+ 5m DAC Cable
JG081C
HPE X2A0 10G SFP+ 7m AOC Cable
JL290A
HPE X2A0 10G SFP+ 10m AOC Cable
JL291A
HPE X2A0 10G SFP+ 20m AOC Cable
JL292A
FC SFP+ Transceivers
HPE StoreFabric 16Gb FC/10GbE 100m SR SFP+ Transceiver
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 1m Direct Attach Copper Splitter Cable
JG329A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 3m Direct Attach Copper Splitter Cable
JG330A
HPE FlexNetwork X240 40G QSFP+ to 4x10G SFP+ 5m Direct Attach Copper Splitter Cable
JG331A
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
JL251A
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
24
HPE X140 40G QSFP+ LC LR4L 2km SM Transceiver
JL286A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
OCA Blue Note - The QSFP+ Splitter Cables (JG329A, JG330A, JG331A, JH700A) are only supported in ports 5-28 for the
JG396A Switch.
The QSFP+ Splitter Cables
Module when used in a 4 slot switch
These modules
JG331A, JH700A) when used in a 4 slot switch(JH398A).
QSFP28 Transceivers
HPE X150 100G QSFP28 MPO SR4 100m MM Transceiver
JL274A
HPE X150 100G QSFP28 LC LR4 10km SM Transceiver
JL275A
HPE X2A0 100G QSFP28 to QSFP28 7m Active Optical Cable
JL276A
HPE X2A0 100G QSFP28 to QSFP28 10m Active Optical Cable
JL277A
HPE X2A0 100G QSFP28 to QSFP28 20m Active Optical Cable
JL278A
HPE X150 100G QSFP28 MPO PSM4 500m SM Transceiver
JH420A
HPE X150 100G QSFP28 CWDM4 2km SM Transceiver
JH673A
HPE X150 100G QSFP28 LC SWDM4 100m MM Transceiver
JH419A
HPE X240 100G QSFP28 to QSFP28 1m Direct Attach Copper Cable
JL271A
HPE X240 100G QSFP28 to QSFP28 3m Direct Attach Copper Cable
JL272A
HPE X240 100G QSFP28 to QSFP28 5m Direct Attach Copper Cable
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 1m Cable
QK732A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 2m Cable
QK733A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 5m Cable
QK734A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 15m Cable
QK735A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 30m Cable
QK736A
HPE Premier Flex LC/LC Multi-mode OM4 2 fiber 50m Cable
QK737A
MPO Cables
HPE Multi Fiber Push On to 4 x Lucent Connector 5m Cable
K2Q46A
HPE Multi Fiber Push On to 4 x Lucent Connector 15m Cable
K2Q47A
HPE Premier Flex MPO/MPO Multi-mode OM4 12 fiber 10m Cable
QK729A
HPE Premier Flex MPO/MPO Multi-mode OM4 8 fiber 50m Cable
QK731A
HPE Premier Flex MPO/MPO OM4 100m (12ft) Cable
H6Z30A
Internal Power Supplies
(JG329A, JG330A, JG331A, JH700A) are only supported on the first 6 ports of the JH183A
(JH398A).
(JH180A, JH181A, JH183A, JH184A, JH182A) do not support the QSFP+ Splitter Cables(JG329A, JG330A,
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
25
(JH390A, JH391A, JH394A, JH395A, JH396A, JH397A) System (std 0 // max 2) User Selection (min 1 //
max 2)
(JH398A) System (std 0 // max 4) User Selection (min 2 // max 4)
HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W AC Power Supply
JG900A
•
See Configuration
NOTE:
PDU Cable NA/MEX/TW/JP
JG900A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W DC Power Supply
JG901A
•
See Configuration
HPE 58x0AF 650W AC Power Supply
JC680A
•
See Configuration
NOTE:1, 2
PDU Cable NA/MEX/TW/JP
JC680A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
HPE 58x0AF 650W AC Power Supply
JC680A
•
See Configuration
NOTE:
PDU Cable NA/MEX/TW/JP
JC680A#B2B
• C15 PDU Jumper Cord (NA/MX/TW/JP)
PDU Cable ROW
JC680A#B2C
• C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC680A#B2E
• HPE 2.3M C13 to NEMA L6-20P Power Cord(J9936A)
No Power Cord Selected
JC680A#AC3
•
HPE FlexFabric Switch 650W 48V Hot Plug NEBS-compliant DC Power Supply
JH336A
See Configuration
NOTE:1
Configuration Rules
Note 1
If 2 power supplies are selected they must be the same SKU number.
Note 2
Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) . (See Localization Menu)
REMARK: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power Cable
option on the Switches/Routers.
Note 3
This power supply is only compatible with the following Switches:
includes 1 x c13, 300w
1, 2, 3
includes 1 x c13, 300w
NOTE:1, 3
includes 1 x c13, 300w
includes 1 x c13, 300w
No Localized Power Cord Selected
• includes 1 x c13, 650w
1, 2
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
26
JH390A
JH395A
Remarks:
Drop down under power supply should offer the following options and results:
Switch/Router to PDU Power Cord
Mexico, Taiwan, and Japan or #B2C ROW. (Watson Default B2B or
B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord
No Power Cord - #AC3 Option
Fan Trays
(JH390A, JH391A, JH394A, JH395A, JH396A, JH397A) System (std 0 // max 2) User Selection (min 2 //
max 2)
(JH398A) System (std 0 // max 2) User Selection (min 2 // max 2)
HPE 58x0AF Back (Power Side) to Front (Port Side) Airflow Fan Tray
JC682A
See Configuration
NOTE:1, 6
HPE 58x0AF Front (Port Side) to Back (Power Side) Airflow Fan Tray
JC683A
See Configuration
NOTE:1, 6
HPE X711 Front (Port Side) to Back (Power Side) Airflow High Volume Fan Tray
JG552A
See Configuration
HPE X712 Back (Power Side) to Front (Port Side) Airflow High Volume Fan Tray
JG553A
See Configuration
NOTE:1, 2
HPE 5930 4-slot Back (Power Side) to Front (Port Side) Airflow Fan Tray
JH185A
See Configuration
NOTE:1, 3
HPE 5930 4-slot Front (Port Side) to Back (Power Side) Airflow Fan Tray
JH186A
See Configuration
NOTE:1, 3
Configuration Rules
Note 1
Fan Trays cannot be mixed in the same switch enclosure
Note 2
This fan tray is only supported on JH390A, JH391A, JH394A, JH395A, JH396A, JH397A.
Note 3
This fan tray is only supported on JH398A.
Note 6
This power supply is only compatible with the following Switches:
JH390A
JH395A
Remarks:
OCA Blue NOTE:
- #B2B in NA,
- Localized Option (Watson Default for BTO and Box Level CTO)
NOTE:1, 2
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Configuration
27
If there is any empty space below the switch in a rack when using Back to Front Fan Trays, JG553A, JH185A and
JC682A, the rack will receive an Air Plenum kit that takes up 1U of additional space in the rack. The Air Plenum kit
is not required on fully configured racks. This only applies for CTO Rack Level Integration. The Air Pl
non-saleable SKU, and is brought in automatically for CTO Factory Rack Level Integration.
enum Kit is a
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
28
HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)
I/O ports and slots
48 fixed 1000/10000 SFP+ ports
6 QSFP+ 40GbE ports
Additional ports and slots
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
1 Mini USB 2.0
Power supplies
2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
This system requires
product warranty.
Physical characteristics
Dimensions
17.32(w) x 18.11(d) x 1.72(h) in (44 x 46 x 4.36 cm)
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
The customer must order fan trays, as fan trays are not included with the switch.
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
s (64-byte packets)
40 to -60 VDC, rated
Part 2
IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
30
Operating relative
humidity
10% to 90%, noncondensing
Acoustic
Low-speed fan: 59.8 dB, High-speed fan: 74.4 dB
Electrical characteristics
Maximum heat
dissipation
597/1361 BTU/hr (629.83/1435.86 kJ/hr)
Voltage
90 - 264 VAC, rated
(depending on power supply chosen)
Maximum power rating
409 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC 61000-4-2
Radiated
EN 61000-4-3; IEC 61000-4-3
EFT/Burst
EN 61000-4-4; IEC 61000-4-4
Surge
EN 61000-4-5; IEC 61000-4-5
Conducted
EN 61000-4-6; IEC 61000-4-6
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
capacity
40 to -60 VDC, rated
Part 2
IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
s (64-byte packets)
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
33
-40 to -60 VDC, rated
(depending on power supply chosen)
Maximum power rating
196 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
The customer must order a power supply, as the device does not come with one. At least one
JC680A or JC681A is required.
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
response times in your area, please contact your local Hewlett Packard Enterprise sales office.
HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)
I/O ports and slots
48 1/10GBASE-T ports
6 QSFP28 100GbE ports
Additional ports and slots
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 SFP GbE port
1 USB 2.0
1 Mini USB 2.0
Power supplies
2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This system requires
two same-direction airflow fan trays to function properly. The system should not be operated with
planning the
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
34
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
product warranty.
Physical characteristics
Dimensions
17.32(w) x 25.98(d) x 1.72(h) in (44 x 66 x 4.36 cm)
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC 61000-4-2
Radiated
EN 61000-4-3; IEC 61000-4-3
EFT/Burst
EN 61000-4-4; IEC 61000-4-4
Surge
EN 61000-4-5; IEC 61000-4-5
Conducted
EN 61000-4-6; IEC 61000-4-6
Power frequency
IEC 61000-4-8; EN 61000-4-8
Voltage dips and
interruptions
EN 61000-4-11; IEC 61000-4-11
Harmonics
EN 61000-3-2, IEC 61000-3-2
Flicker
EN 61000-3-3, IEC 61000-3-3
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
capacity
40 to -60 VDC, rated
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
more than two minutes. The system should not be operated outside of the temperature range of
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
s (64-byte packets)
40 to -75 VDC, rated
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
36
Notes
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst
case theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
The customer must order a power supply, as the device does not come with one. At least one
JC680A or JC681A is required.
Services
Refer to the Hewlett Packard Enterprise website at: http://www.hpe.com/networking/services for
response times in your area, please contact your local Hewlett Packard Enterprise sales office.
HPE FlexFabric 5940 4-slot Switch (JH398A)
I/O ports and slots
4 module slots
Supports a maximum of 32 40GbE ports or 96 1/10GBASE-T ports or 96 SFP+ ports or 96
Converged ports, or a combination
Additional ports and slots
1 RJ-45 serial console port
1 RJ-45 out-of-band management port
1 USB 2.0
1 Mini USB 2.0
Power supplies
4 power supply slots
2 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
The customer must order fan trays, as fan trays are not included with the switch. This system requires
more than two minutes. The system should not be operated outside of the temperature range of
-
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
two same-direction airflow fan trays to function properly. The system should not be operated with
only one fan tray for more than 24 hours. The system should not be operated without a fan tray for
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
37
32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the
product warranty.
Physical characteristics
Dimensions
17.32(w) x 25.98(d) x 3.47(h) in (44.00 x 66.0 x 8.81 cm) (2U height)
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst
case theoretical maximum numbers provided for planning the
infrastructure with fully loaded
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
ESD
EN 61000-4-2; IEC 61000-4-2
Radiated
EN 61000-4-3; IEC 61000-4-3
EFT/Burst
EN 61000-4-4; IEC 61000-4-4
Surge
EN 61000-4-5; IEC 61000-4-5
Conducted
EN 61000-4-6; IEC 61000-4-6
Power frequency
magnetic field
IEC 61000-4-8; EN 61000-4-8
Voltage dips and
interruptions
EN 61000-4-11; IEC 61000-4-11
40 to -75 VDC, rated
-
PoE (if equipped), 100% traffic, all ports
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
details on the service-level descriptions and product numbers. For details about services and
This system requires two samebe operated with only one fan tray for more than 24 hours. The system should not be operated
without a fan tray for more than two minutes. The system should not be operated outside of the
temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating
s (64-byte packets)
40 to -60 VDC, rated
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
39
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
This system requires two samebe operated with only one fan tray for more than 24 hours. The system should not be operated
without a fan tray for more than two minutes. The system should not be operated outside of the
temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
40
Performance
10 Gbps Latency
< 1 µs (64-byte packets)
Throughput
up to 1607 Mpps
Routing/Switching
capacity
2160 Gbps
Routing table size
120000 entries (IPv4), 60000 entries (IPv6)
MAC address table size
288000 entries
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
humidity
10% to 90%, noncondensing
Acoustic
Low-speed fan: 65.7 dB, High-speed fan: 70.6 dB
Electrical characteristics
Maximum heat
dissipation
887 BTU/hr (935.79 kJ/hr)
Voltage
100 - 240 VAC, rated
(depending on power supply chosen)
Maximum power rating
320 W
Frequency
50/60 Hz
Notes
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Maximum power rating and maximum heat dissipation are the worstcase theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Immunity
Generic
EN 55024:1998+ A1:2001 + A2:2003
EN
EN 61000-4-2; IEC 61000-4-2
2 power supply slots
This system requires two samebe operated with only one fan tray for more than 24 hours. The system should not be operated
without a fan tray for more than two minutes. The system should not be operated outside of the
temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating
humidity
40 to -75 VDC, rated
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
details on the service-level descriptions and product numbers. For details about services and
1 QSFP+ 40GbE ports
Converged ports, or a combination
This system requires two samebe operated with only one fan tray for more than 24 hours. The system should not be operated
without a fan tray for more than two minutes. The system should not be operated outside of the
temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
43
Reliability
MTBF (years)
47.2
MTTR (hours)
1
Environment
Operating temperature
32°F to 113°F (0°C to 45°C)
Operating relative
humidity
10% to 90%, noncondensing
Acoustic
Low-speed fan: 59.8 dB, High-speed fan: 74.4 dB
Electrical characteristics
Voltage
90 - 264 VAC, rated
(depending on power supply chosen)
Maximum power rating
508 W
Idle power
105 W
Frequency
50/60 Hz
Notes
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the worst
case theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
Idle power is the actual power consumption of the device with no ports
connected.
Maximum power rating and maximum heat dissipation are the
case theoretical maximum numbers provided for planning the
infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports
plugged in, and all modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-
1/A11; FDA 21
CFR Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
(CFR 47, Part 15) Class A; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED)
This system requires two samebe operated with only one fan tray for more than 24 hours. The system should not be operated
without a fan tray for more than two minutes. The system should not be operated outside of the
temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating
s (64-byte packets)
40 to -75 VDC, rated
Part 2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC
IEEE 802.1AX-2008 Link Aggregation
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
46
IEEE 802.1s Multiple Spanning Trees
RFC 3417 Transport Mappings for the Simple Network Management Protocol (SNMP)
IEEE 802.1w Rapid Reconfiguration of Spanning Tree
IEEE 802.3ad Link Aggregation Control Protocol (LACP)
IEEE 802.3ae 10-Gigabit Ethernet
IEEE 802.3ag Ethernet OAM
IEEE 802.3ah Ethernet in First Mile over Point to Point Fiber - EFMF
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 791 IP
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 856 TELNET
RFC 868 Time Protocol
RFC 896 Congestion Control in IP/TCP Internetworks
RFC 950 Internet Standard Subnetting Procedure
RFC 1027 Proxy ARP
RFC 1058 RIPv1
RFC 1091 Telnet Terminal-Type Option
RFC 1141 Incremental updating of the Internet checksum
RFC 1142 OSI IS-IS Intra-domain Routing Protocol
RFC 1191 Path MTU discovery
RFC 1213 Management Information Base for Network Management of TCP/IP-based internets
RFC 1253 (OSPF v2)
RFC 1531 Dynamic Host Configuration Protocol
RFC 1533 DHCP Options and BOOTP Vendor Extensions
RFC 1534 DHCP/BOOTP Interoperation
RFC 1541 DHCP
RFC 1542 Clarifications and Extensions for the Bootstrap Protocol
RFC 1591 DNS (client only)
RFC 1624 Incremental Internet Checksum
RFC 1723 RIP v2
RFC 1812 IPv4 Routing
RFC 2030 Simple Network Time Protocol (SNTP) v4
RFC 2131 DHCP
RFC 2236 IGMP Snooping
RFC 2338 VRRP
RFC 2453 RIPv2
RFC 2581 TCP Congestion Control
RFC 2644 Directed Broadcast Control
RFC 2767 Dual Stack Hosts using BIS
RFC 2865 Remote Authentication Dial In User Service (RADIUS)
RFC 2868 RADIUS Attributes for Tunnel Protocol Support
RFC 2890 Key and Sequence Number Extensions to GRE
RFC 2929 DNS IANA Considerations
RFC 3046 DHCP Relay Agent Information Option
RFC 3411 An Architecture for Describing Simple Network Management Protocol (SNMP)
Management Frameworks
RFC 3412 Message Processing and Dispatching for the Simple Network Management Protocol
(SNMP)
RFC 3413 Simple Network Management Protocol (SNMP) Applications
RFC 3416 Protocol Operations for SNMP
Page
QuickSpecs
HPE FlexFabric 5940 Switch Series
Technical Specifications
47
RFC 3418 Management Information Base (MIB) for the Simple Network Management Protocol
RFC 5905 Network Time Protocol Version 4: Protocol and Algorithms Specification
IPv6
RFC 2080 RIPng for IPv6
RFC 5095 Deprecation of Type 0 Routing Headers in IPv6
MIBs
RFC 1213 MIB II
LLDP-EXT-DOT3-MIB
(SNMP)
RFC 3768 Virtual Router Redundancy Protocol (VRRP)
RFC 4250 The Secure Shell (SSH) Protocol Assigned Numbers
RFC 4251 The Secure Shell (SSH) Protocol Architecture
RFC 4252 The Secure Shell (SSH) Authentication Protocol
RFC 4253 The Secure Shell (SSH) Transport Layer Protocol
RFC 4254 The Secure Shell (SSH) Connection Protocol
RFC 4292 IP Forwarding Table MIB
RFC 4293 Management Information Base for the Internet Protocol (IP)
RFC 4364 BGP/MPLS IP Virtual Private Networks (VPNs)
RFC 4419 Diffie-Hellman Group Exchange for the Secure Shell (SSH) Transport Layer Protocol
RFC 4594 Configuration Guidelines for DiffServ Service Classes
RFC 4601 Protocol Independent Multicast - Sparse Mode (PIM-SM): Protocol Specification (Revised)
RFC 4604 Using Internet Group Management Protocol Version 3 (IGMPv3) and Multicast Listener
Discovery Protocol Version 2 (MLDv2) for Source-Specific Multicast
RFC 4607 Source-Specific Multicast for IP
RFC 4941 Privacy Extensions for Stateless Address Autoconfiguration in IPv6
RFC 5340 OSPF for IPv6
RFC 2460 IPv6 Specification
RFC 2461 IPv6 Neighbor Discovery
RFC 2462 IPv6 Stateless Address Auto-configuration
RFC 2463 ICMPv6
RFC 2464 Transmission of IPv6 over Ethernet Networks
RFC 2473 Generic Packet Tunneling in IPv6
RFC 2545 Use of MP-BGP-4 for IPv6
RFC 2563 ICMPv6
RFC 2711 IPv6 Router Alert Option
RFC 2740 OSPFv3 for IPv6
RFC 2767 Dual Stack Hosts using BIS
RFC 3315 DHCPv6 (client and relay)
RFC 3484 Default Address Selection for IPv6
RFC 3810 Multicast Listener Discovery Version 2 (MLDv2) for IPv6
RFC 4213 Basic Transition Mechanisms for IPv6 Hosts and Routers
RFC 4291 IP Version 6 Addressing Architecture
RFC 4443 ICMPv6
RFC 4552 Authentication/Confidentiality for OSPFv3
RFC 4862 IPv6 Stateless Address Auto-configuration
RFC 2475 DiffServ Architecture
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 3247 Supplemental Information for the New Definition of the EF PHB (Expedited Forwarding PerHop Behavior)
RFC 2818 HTTP Over TLS
RFC 6192 Partial Support - Protecting the Router Control Plane
Access Control Lists (ACLs)