The HPE FlexFabric 5930 Switch Series is a family of high performance and ultra-low-latency
10GbE and 40GbE top-of-rack (ToR) data center switches. The switch series is part of the
Hewlett Packard Enterprise FlexFabric data center solution, which is a cornerstone of the
FlexNetwork architecture.
The FlexFabric 5930 Switch Series is ideally suited for deployment at the aggregation or
server access layer of large enterprise data centers, or at the core layer of medium-sized
enterprises.
With the increase pace of deploying virtualized applications, adopting software-defined
networking, and the server-to-server traic, many data centers now require spine and ToR
switch innovations that will meet their requirements. The HPE FlexFabric 5930 is optimized to
meet the increasing requirements for higher-performance server connectivity, convergence of
Ethernet and storage traic, the capability to handle virtual environments, and ultra-low-latency.
A summary of the highlights of the FlexFabric 5930 Switch Series:
• VXLAN VTEP support for virtualized environments
• OpenFlow support for investment protection and SDN environments
• High-density 10GbE and 40GbE for spine-and–leaf deployments
• Unify management of virtual and physical network with VEPA and IMC
• Data center convergence and resiliency with DCB, FC/FCoE, IRF, and TRILL
Data sheet
Page 2
Features and benefits
Quality of Service (QoS)
• Powerful QoS features
– Flexible queue scheduling
Including Strict Priority (SP), WRR, WDRR, WFQ, SP+WRR, SP+WDRR, SP+WFQ, Configurable
Buer, Time range, Queue Shaping, CAR with 8kbps granularity
– Packet filtering and remarking
Packet filtering at Layer 2 (L2) through Layer 4 (L4); flow classification based on source
MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/
IPv6) address, port, protocol, and VLAN
Data center optimized
• Flexible high port density
The HPE FlexFabric 5930 Switch Series enables scaling of the server edge with 10GbE and
40GbE spine and ToR deployments to new heights with a high-density 32-port fixed port
switch in a 1RU design, a 2 Slot Modular design with Two 40GbE QSFP+ ports and a 4 Slot
Design. Support for 10GbE SFP+, 10GBASE-T, Converged Port 1/10GbE or 4/8Gbps Fibre
Channel, and 40GbE ports
• High-performance switching
Cut-through and nonblocking architecture delivers low latency (1 microsecond for 10GbE)
for very demanding enterprise applications; the switch delivers high-performance switching
capacity and wire-speed packet forwarding
• Higher scalability
The Hewlett Packard Enterprise Intelligent Resilient Framework (IRF) technology simplifies
the architecture of server access networks; up to nine 5930 switches can be combined
to deliver unmatched scalability of virtualized access layer switches and flatter two-tier
networks using IRF, which reduces cost and complexity
• Advanced modular operating system
Comware v7 software’s modular design and multiple processes bring native high stability,
independent process monitoring, and restart; the OS also allows individual software modules
to be upgraded for higher availability and supports enhanced serviceability functions such as
hitless software upgrades with single-chassis ISSU
Data sheet
Page 3
• TRILL, SPB, and EVB/VEPA
TRansparent Interconnection of Lots of Links (TRILL) is supported including support of TRILL
with IRF, TRILL ECMP up to 8 paths. Support for Shortest Path Bridging (IEEE 8021aq) with
ECMP up to 8 paths. Edge Virtual Bridging with Virtual Ethernet Port Aggregator (EVB/VEPA)
provides connectivity into the virtual environment for a data center-ready environment
• Reversible airflow
Enhanced for data center hot-cold aisle deployment with reversible airflow—for either
front-to-back or back-to-front airflow
• Redundant fans and power supplies
Internal redundant and hot-pluggable power supplies and dual fan trays enhance reliability
and availability
• Lower OPEX and greener data center
Provide reversible airflow and advanced chassis power management
• Data Center Bridging (DCB) protocols
Provides support for IEEE 8021Qbb Priority Flow Control (PFC), Data Center Bridging
Exchange (DCBX), IEEE 8021Qaz Enhanced Transmission Selection (ETS), Explicit Congestion
Notification (ECN) for converged FCoE, iSCSI, and RoCE environments
• FCoE support
Provides support T11 standards-compliant FC-BB-5 Fibre Channel over Ethernet (FCoE),
including FCoE Initialization Protocol (FIP), FCP, Fibre Channel enhanced port types VE, TE and
VF, NPV, NPIV, Fabric Name Server, RSCN, Login Services, and name-server zoning, per-VSAN
Fabric Services, FSPF, Standard Zoning, and Fibre Channel Ping
• Jumbo frames
With frame sizes of up to 10000 bytes on Gigabit Ethernet and 10 Gigabit ports,
high-performance remote backup and disaster-recovery services are enabled
• VXLAN support
VXLAN Layer 2 gateway support for up to 4k tunnels
Data sheet
Page 4
Manageability
• Full-featured console
Provides complete control of the switch with a familiar command-line interface (CLI)
• Troubleshooting
– Ingress and egress port monitoring
Enable network problem solving
– Traceroute and ping
Enable testing of network connectivity
• Multiple configuration files
Allow multiple configuration files to be stored to a flash image
• sFlow® (RFC 3176)
Provides wire-speed traic accounting and monitoring
• SNMPv1, v2c, and v3
Facilitate centralized discovery, monitoring, and secure management of networking devices
• Out-of-band interface
Isolates management traic from user data plane traic for complete isolation and total
reachability, no matter what happens in the data plane
• Remote configuration and management
Delivered through a secure CLI over Telnet and SSH; Role-Based Access Control (RBAC)
provides multiple levels of access; Configuration Rollback and multiple configurations on
the flash provide ease of operation; remote visibility is provided with sFlow and SNMPv1/
v2/v3 and is fully supported in the HPE Intelligent Management Center (IMC)
• ISSU and hot patching
Provides hitless software upgrades with single-unit In Services Software Upgrade (ISSU)
and hitless patching of the modular operating system
• Autoconfiguration
Provides automatic configuration via DHCP autoconfiguration
• NTP, SNTP
Synchronize timekeeping among distributed time servers and clients; Support for Network
Time Protocol (NTP), Secure Network Time Protocol (SNTP), IEEE 1588v2 (2008)
Data sheet
Page 5
Resiliency and high availability
• Hewlett Packard Enterprise IRF technology
Enables a FlexFabric solution to deliver resilient, scalable, and secured data center networks for
physical and virtualized environments; groups up to nine 5930 switches in an IRF configuration,
allowing them to be configured and managed as a single switch with a single IP address; and
simplifies ToR deployment and management, reducing data center deployment and operating
expenses
• IEEE 8021w Rapid Convergence Spanning Tree Protocol
Increases network uptime through faster recovery from failed links
• IEEE 8021s Multiple Spanning Tree
Provides high link availability in multiple VLAN environments by allowing multiple spanning
trees
• Virtual Router Redundancy Protocol (VRRP)
Allows groups of two routers to dynamically back each other up to create highly available
routed environments
• Hitless patch upgrades
Allows patches and new service features to be installed without restarting the equipment,
increasing network uptime and facilitating maintenance
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF,
BGP, IS-IS, VRRP, MPLS, and IRF
• Device Link Detection Protocol (DLDP)
Monitors link connectivity and shuts down ports at both ends if unidirectional traic is detected,
helping prevent loops in STP-based networks
• Graceful restart
Allows routers to indicate to others their capability to maintain a routing table during a
temporary shutdown and significantly reduces convergence times upon recovery; and
supports OSPF, BGP, and IS-IS
Data sheet
Page 6
L2 switching
• MAC-based VLAN
Provides granular control and security; and uses RADIUS to map a MAC address/user to specific
VLANs
• Address Resolution Protocol (ARP)
Supports static, dynamic, and reverse ARP and ARP proxy
• IEEE 8023x Flow Control
Provides intelligent congestion management via PAUSE frames
• Ethernet Link Aggregation
Provides IEEE 8023ad Link Aggregation of up to 128 groups of 16 ports; and support for
LACP, LACP Local Forwarding First, and LACP Short-time provides a fast, resilient environment
that is ideal for the data center
Provides support for 4096 VLANs based on the port, MAC address, IPv4 subnet, protocol,
and guest VLAN; and supports VLAN mapping
• IGMP support
Provides support for IGMP Snooping, Fast-Leave, and Group-Policy; IPv6 IGMP Snooping
provides L2 optimization of multicast traic
• DHCP support at L2
Provides full DHCP Snooping support for DHCP Snooping Option 82, DHCP Relay Option
82, DHCP Snooping Trust, and DHCP Snooping Item Backup
Data sheet
Page 7
L3 services
• Address Resolution Protocol (ARP)
Determines the MAC address of another IP host in the same subnet; supports static ARPs;
gratuitous ARP allows detection of duplicate IP addresses; proxy ARP allows normal ARP
operation between subnets or when subnets are separated by an L2 network
• Dynamic Host Configuration Protocol (DHCP)
Simplifies the management of large IP networks and supports client and server; DHCP Relay
enables DHCP operation across subnets
• Operations, administration and maintenance (OAM) support
Provides support for Connectivity Fault Management (IEEE 8021AG) and Ethernet in the
First Mile (IEEE 8023AH); and provides additional monitoring that can be used for fast fault
detection and recovery
L3 routing
• Virtual Router Redundancy Protocol (VRRP) and VRRP Extended
Allow quick failover of router ports
• Policy-based routing
Makes routing decisions, based on policies set by the network administrator
• Equal-Cost Multipath (ECMP)
Enables multiple equal-cost links in a routing environment to increase link redundancy and
scale bandwidth
• L3 IPv4 routing
Provides routing of IPv4 at media speeds; and supports static routes, RIP and RIPv2, OSPF,
BGP, and IS-IS
• Open shortest path first (OSPF)
Delivers faster convergence; and uses this link-state routing Interior Gateway Protocol (IGP),
which supports ECMP, NSSA, and MD5 authentication, for increased security and graceful
restart for faster failure recovery
Data sheet
Page 8
• Border Gateway Protocol 4 (BGP-4)
Delivers an implementation of the Exterior Gateway Protocol (EGP), utilizing path vectors; uses
TCP for enhanced reliability for the route discovery process; reduces bandwidth consumption
by advertising only incremental updates; supports extensive policies for increased flexibility; and
scales to very large networks
• Intermediate system to intermediate system (IS-IS)
Uses a path-vector IGP, which is defined by the ISO organization for IS-IS routing and extended
by IETF RFC 1195 to operate in both TCP/IP and the OSI reference model (Integrated IS-IS)
• Static IPv6 routing
Provides simple manually configured IPv6 routing
• Dual IP stack
Maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network
to an IPv6-only network design
• Routing Information Protocol next generation (RIPng)
Extends RIPv2 to support IPv6 addressing
• OSPFv3
Provides OSPF support for IPv6
• BGP+
Extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
• IS-IS for IPv6
Extends IS-IS to support IPv6 addressing
• IPv6 tunneling
Allows IPv6 packets to traverse IPv4-only networks by encapsulating the IPv6 packet into a
standard IPv4 packet; supports manually configured, 6-to-4, and Intra-Site Automatic Tunnel
Addressing Protocol (ISATAP) tunnels; and is an important element for the transition from
IPv4 to IPv6
Data sheet
Page 9
• Policy routing
Allows custom filters for increased performance and security; and supports ACLs, IP prefix,
AS paths, community lists, and aggregate policies
• Bidirectional Forwarding Detection (BFD)
Enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP,
IS-IS, VRRP, MPLS, and IRF
• Multicast Routing PIM Dense and Sparse modes
Provides robust support of multicast protocols
• L3 IPv6 routing
Provides routing of IPv6 at media speeds; and supports static routing, RIPng, OSPFv3, BGP4+
for IPv6, and IS-ISv6
Additional information
• Green IT and power
Improves energy eiciency through the use of the latest advances in silicon development;
and shuts o unused ports and utilizes variable-speed fans, reducing energy costs
Management
• USB support
– File copy
Allows users to copy switch files to and from a USB flash drive
• Multiple configuration files
Stores easily to the flash image
• SNMPv1, v2c, and v3
Facilitate centralized discovery, monitoring, and secure management of networking devices
Data sheet
Page 10
• Out-of-band interface
Isolates management traic from user data plane traic for complete isolation and total
reachability, no matter what happens in the data plane
• Port mirroring
Enables traic on a port to be simultaneously sent to a network analyzer for monitoring
• Remote configuration and management
Is available through a CLI
• IEEE 8021AB Link Layer Discovery Protocol (LLDP)
Advertises and receives management information from adjacent devices on a network,
facilitating easy mapping by network management applications
• sFlow (RFC 3176)
Provides scalable ASIC-based wirespeed network monitoring and accounting with no impact
on network performance; this allows network operators to gather a variety of sophisticated
network statistics and information for capacity planning and real-time network monitoring
purposes
• Command authorization
Leverages RADIUS to link a custom list of CLI commands to an individual network
administrator’s login; an audit trail documents activity
• Dual flash images
Provides independent primary and secondary operating system files for backup while upgrading
• Command-Line Interface (CLI)
Provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console;
and provides direct real-time session visibility
• Logging
Provides local and remote logging of events via SNMP (v2c and v3) and syslog; and provides
log throttling and log filtering to reduce the number of log events generated
Data sheet
Page 11
• Management interface control
Provides management access through a modem port and terminal interface, as well as in-band
and out-of-band Ethernet ports; and provides access through the terminal interface, telnet, or
secure shell (SSH)
• Industry-standard CLI with a hierarchical structure
Reduces training time and expenses; and increases productivity in multivendor installations
• Management security
Restricts access to critical configuration commands; and oers multiple privilege levels with
password protection; ACLs provide telnet and SNMP access, while local and remote syslog
capabilities allow logging of all access
• Information center
Provides a central repository for system and network information; aggregates all logs, traps, and
debugging information generated by the system and maintains them in the order of severity; and
sends out the network information to multiple channels based on user-defined rules
• Network management
HPE Intelligent Management Center (IMC) centrally configures, updates, monitors, and
troubleshoots
• Remote intelligent mirroring
Mirrors ingress/egress ACL-selected traic from a switch port or VLAN to a local or remote
switch port anywhere on the network
Data sheet
Page 12
Security
• Access control lists (ACLs)
Provide IP Layer 3 filtering based on source/destination IP address/subnet and source/
destination TCP/UDP port number
• RADIUS/TACACS+
Eases switch management security administration by using a password authentication server
• Secure shell
Encrypts all transmitted data for secure remote CLI access over IP networks
• IEEE 8021X and RADIUS network logins
Controls port-based access for authentication and accountability
• Port security
Allows access only to specified MAC addresses, which can be learned or specified by the
administrator
Convergence
• LLDP-MED (Media Endpoint Discovery)
Defines a standard extension of LLDP that stores values for parameters such as QoS and
VLAN to automatically configure network devices such as IP phones
Warranty and support
• 1-year warranty
See hpe.com/networking/warrantysummary for warranty and support information included
with your product purchase
• Software releases
To find software for your product, refer to hpe.com/networking/support; for details on
the software releases available with your product purchase, refer to hpe.com/networking/
Additional ports and slots1 RJ-45 serial console por t
Power supplies2 power supply slots
Fan tray2 fan tray slots
Physical characteristics
Dimensions
Weight
Full configuration weight
(JG726A )
1 RJ-45 out-of-band management port
1 USB 20
1 minimum power supply required
(ordered separately)
The customer must order fan trays, as
fan trays are not included with the switch.
This system requires two same-direction
airflow fan trays to function properly. The
system should not be operated with only
one fan tray for more than 24 hours. The
system should not be operated without a
fan tray for more than t wo minutes. The
system should not be operated outside
of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with
these operating requirements may void
the product warranty.
1732(w) x 2598(d) x 172(h) in.
(4400 x 660 x 436 cm)
3527 lb (16 kg) shipping weight
2866 lb (13 kg)
HPE FlexFabric 59304-slot Switch
(JH179A )
1 RJ-45 serial console por t
1 RJ-45 out-of-band management port
1 USB 20
4 power supply slots
2 minimum power supplies required
(ordered separately)
2 fan tray slots
The customer must order fan trays, as
fan trays are not included with the switch.
This system requires two same-direction
airflow fan trays to function properly. The
system should not be operated with only
one fan tray for more than 24 hours. The
system should not be operated without a
fan tray for more than t wo minutes. The
system should not be operated outside
of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with
these operating requirements may void
the product warranty.
1732(w) x 2598(d) x 347(h) in.
(4400 x 660 x 881 cm) (2U height)
6614 lb (30 kg) shipping weight
5952 lb (27 kg)
HPE FlexFabric 59302QSFP+ 2-slot
Switch (JH178A)
2 QSFP+ 40GbE por ts
1 RJ-45 serial console por t
1 RJ-45 out-of-band management port
1 USB 20
2 power supply slots
1 minimum power supply required
(ordered separately)
2 fan tray slots
The customer must order fan trays, as
fan trays are not included with the switch.
This system requires two same-direction
airflow fan trays to function properly. The
system should not be operated with only
one fan tray for more than 24 hours. The
system should not be operated without a
fan tray for more than t wo minutes. The
system should not be operated outside
of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with
these operating requirements may void
the product warranty.
1732(w) x 2598(d) x 174(h) in.
(4400 x 660 x 442 cm) (1U height)
3968 lb (18 kg) shipping weight
3527 lb (16 kg)
Memory and processor1 GB flash; Packet buer size: 122 MB,
-40 to -75 VDC, rated
(depending on power supply chosen)
399 W
175 W
Notes
Idle power is the actual power
consumption of the device with no
ports connected.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning
the infrastructure with fully loaded PoE
(if equipped), 100% traic, all ports
plugged in, and all modules populated.
HPE FlexFabric 59304-slot Switch
(JH179A )
358
1
32°F to 113°F (0°C to 45°C)
10% to 90%, noncondensing
Low-speed fan: 598 dB,
High-speed fan: 744 dB
-40 to -75 VDC, rated
(depending on power supply chosen)
888 W
139 W
Idle power is the actual power
consumption of the device with no
ports connected.
Maximum power rating and maximum heat
dissipation are the worst-case theoretical
maximum numbers provided for planning
the infrastructure with fully loaded PoE
(if equipped), 100% traic, all ports
plugged in, and all modules populated.
HPE FlexFabric 59302QSFP+ 2-slot
Switch (JH178A)
47 2
1
32°F to 113°F (0°C to 45°C)
10% to 90%, noncondensing
Low-speed fan: 598 dB,
High-speed fan: 744 dB
-40 to -75 VDC, rated
(depending on power supply chosen)
508 W
105 W
Idle power is the actual power
consumption of the device with no
ports connected.
Maximum power rating and maximum h eat
dissipation are the worst-case theoretical
maximum numbers provided for planning
the infrastructure with fully loaded PoE
(if equipped), 100% traic, all ports
plugged in, and all modules populated.
SafetyUL 60950-1; EN 60825-1 Safety of Laser
Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60950-1;
CAN/CSA-C222 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
EmissionsVCCI Class A; EN 55022 Class A;
ICES-003 Class A; ANSI C6342003;
AS/NZS CISPR 22 Class A;
EN 61000-3-22006;
EN 6100 0-3-31995 +A120 01+A22005;
EMC Directive 2004/108/EC; FCC (CFR 47,
Part 15) Class A; ANSI/TIA-1057 LLDP
Media Endpoint Discovery (LLDP-MED)
UL 60950-1; EN 60825-1 Safety of Laser
Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60950-1;
CAN/CSA-C222 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
VCCI Class A; EN 55022 Class A;
ICES-003 Class A; ANSI C6342003;
AS/NZS CISPR 22 Class A;
EN 61000-3-22006;
EN 6100 0-3-31995 +A120 01+A22005;
EMC Directive 2004/108/EC; FCC (CFR 47,
Part 15) Class A; ANSI/TIA-1057 LLDP
Media Endpoint Discovery (LLDP-MED)
UL 60950-1; EN 60825-1 Safety of Laser
Products-Part 1; EN 60825-2 Safety of
Laser Products-Part 2; IEC 60950-1;
CAN/CSA-C222 No. 60950-1; Anatel;
ULAR; GOST; EN 60950-1/A11;
FDA 21 CFR Subchapter J; NOM; ROHS
Compliance
VCCI Class A; EN 55022 Class A;
ICES-003 Class A; ANSI C6342003;
AS/NZS CISPR 22 Class A;
EN 61000-3-22006;
EN 6100 0-3-31995 +A120 01+A22005;
EMC Directive 2004/108/EC; FCC (CFR 47,
Part 15) Class A; ANSI/TIA-1057 LLDP
Media Endpoint Discovery (LLDP-MED)
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
ManagementIMC—Intelligent Management Center;
NotesThe customer must order a power supply,
ServicesRefer to the Hewlet t Packard Enterprise
(JG726A )
ETSI EN 300386 V133
EN 550241998+ A12001 + A22003
EN 61000-4-2; IEC 61000-4-2
EN 6100 0-4-3; IEC 6100 0 -4-3
EN 61000-4-4; IEC 61000-4-4
EN 61000-4-5; IEC 61000-4-5
EN 61000-4-6; IEC 61000-4-6
IEC 61000-4-8; EN 61000-4-8
EN 61000-4-11; IEC 61000-4-11
EN 6100 0-3-2, I EC 610 00 -3-2
EN 6100 0-3-3, IEC 61000-3-3
as the device does not come with one. At
least one JC680A or JC681A is required.
website at hpe.com/networking/services for details on the service-level
descriptions and product numbers. For
details about services, and response times
in your area, please contact your local
Hewlett Packard Enterprise sales oice.
HPE FlexFabric 59304-slot Switch
(JH179A )
ETSI EN 300386 V133
EN 550241998+ A12001 + A22003
EN 61000-4-2; IEC 61000-4-2
EN 6100 0-4-3; IEC 6100 0 -4-3
EN 61000-4-4; IEC 61000-4-4
EN 61000-4-5; IEC 61000-4-5
EN 61000-4-6; IEC 61000-4-6
IEC 61000-4-8; EN 61000-4-8
EN 61000-4-11; IEC 61000-4-11
EN 6100 0-3-2, I EC 610 00 -3-2
EN 6100 0-3-3, IEC 61000-3-3
The customer must order a power supply,
as the device does not come with one. At
least one JC680A or JC681A is required.
Refer to the Hewlet t Packard Enterprise
website at hpe.com/networking/services for details on the service-level
descriptions and product numbers. For
details about services, and response times
in your area, please contact your local
Hewlett Packard Enterprise sales oice.
HPE FlexFabric 59302QSFP+ 2-slot
Switch (JH178A)
ETSI EN 300386 V133
EN 550241998+ A12001 + A22003
EN 61000-4-2; IEC 61000-4-2
EN 6100 0-4-3; IEC 6100 0 -4-3
EN 61000-4-4; IEC 61000-4-4
EN 61000-4-5; IEC 61000-4-5
EN 61000-4-6; IEC 61000-4-6
IEC 61000-4-8; EN 61000-4-8
EN 61000-4-11; IEC 61000-4-11
EN 6100 0-3-2, I EC 610 00 -3-2
EN 6100 0-3-3, IEC 61000-3-3
The customer must order a power supply,
as the device does not come with one. At
least one JC680A or JC681A is required.
Refer to the Hewlet t Packard Enterprise
website at hpe.com/networking/services for details on the service-level
descriptions and product numbers. For
details about services, and response times
in your area, please contact your local
Hewlett Packard Enterprise sales oice.
RFC 3046 DHCP Relay Agent Information
Option
RFC 3411 An Architecture for Describing
Simple Network Management Protocol
(SNMP) Management Frameworks
RFC 3412 Message Processing and
Dispatching for the Simple Network
Management Protocol (SNMP)
RFC 3413 Simple Network Management
Protocol (SNMP) Applications
RFC 3416 Protocol Operations for SNMP
RFC 3417 Transpor t Mappings for the Simple
Network Management Protocol (SNMP)
RFC 3418 Management Information Base
(MIB) for the Simple Net work Management
Protocol (SNMP)
RFC 3768 Virtual Router Redundancy
Protocol (VRRP)
RFC 4250 The Secure Shell (SSH) Protocol
Assigned Numbers
RFC 4251 The Secure Shell (SSH) Protocol
Architecture
RFC 4252 The Secure Shell (SSH)
Authentication Protocol
RFC 4253 The Secure Shell (SSH) Transport
Layer Protocol
RFC 4254 The Secure Shell (SSH) Connection
Protocol
RFC 4292 IP Forwarding Table MIB
RFC 4293 Management Information Base for
the Internet Protocol (IP)
RFC 4364 BGP/MPLS IP Virtual Private
Networks (VPNs)
RFC 4419 Diie-Hellman Group Exchange
for the Secure Shell (SSH) Transport Layer
Protocol
Data sheet
Standards and protocols (continued)
(applies to all products in series)
Page 17
General protocols
IPv6RFC 2080 RIPng for IPv6
MIBsRFC 1213 MIB II
Network managementRFC 2580 Conformance Statements for
OSPFRFC 1587 OSPF NSSA
RFC 4594 Configuration Guidelines for
DiServ Service Classes
RFC 4601 Protocol Independent
Multicast—Sparse Mode (PIM-SM): Protocol
Specification (Revised)
RFC 4604 Using Internet Group Management
Protocol Version 3 (IGMPv3) and Multicast
Listener Discovery Protocol Version 2
(MLDv2) for Source-Specific Multicast
RFC 4607 Source-Specific Multicast for IP
RFC 2545 Use of MP-BGP-4 for IPv6
RFC 2563 ICMPv6
RFC 2711 IPv6 Router Alert Option
RFC 2740 OSPFv3 for IPv6
RFC 2767 Dual stacks IPv46 & IPv6
RFC 3315 DHCPv6 (client and relay)
RFC 3484 Default Address Selection for
IPv6
RFC 3810 Multicast Listener Discovery
Version 2 (MLDv2) for IPv6
RFC 3623 Graceful OSPF Restart
RFC 4577 OSPF as the Provider/Customer
Edge Protocol for BGP/MPLS IP Vir tual
Private Networks (VPNs)
RFC 4941 Privacy Extensions for
Stateless Address Autoconfiguration in
IPv6 RFC 5340 OSPF for IPv6
RFC 5905 Network Time Protocol Version 4:
Protocol and Algorithms Specification
RFC2929 RADIUS Support DS for Radius
RFC 4213 Basic Transition Mechanisms for
IPv6 Hosts and Routers
RFC 4291 IP Version 6 Addressing
Architecture
RFC 4443 ICMPv6
RFC 4552 Authentication/Confidentiality
for OSPFv3
RFC 4862 IPv6 Stateless Address
RFC 5095 Deprecation of Type 0 Routing
Headers in IP v6
RFC 3247 Supplemental Information for the
New Definition of the EF PHB (Expedited
Forwarding Per-Hop Behavior)
RFC 2818 HTTP Over TLS
RFC 6192 Par tial Support-Protecting the
Router Control Plane
RFC 3260 New Terminology and
Clarifications for DiServ
Access Control Lists (ACLs)
SSHv2 Secure Shell
Data sheet
HPE FlexFabric 5930 Switch Series accessories
Page 18
TransceiversHPE X14040 G QSFP+ LC ER440 km SM Transceiver (JL306A)
HPE X14040 G QSFP+ LC LR4 SM 10 km 1310 nm Transceiver (JG661A)
HPE X14040 G QSFP+ LC LR4L 2 km SM Transceiver (JL286A)
HPE X14040 G QSFP+ MPO SR4 Transceiver (JG325B)
HPE X14040 G QSFP+ MPO MM 850 nm CSR4300 m Transceiver (JG709A)
HPE X14040 G QSFP+ LC BiDi 100 m MM Transceiver (JL251A)
HPE X24040 G QSFP+ to QSFP+ 1 m Direct Attach Copper Cable (JG326A)
HPE X24040 G QSFP+ to QSFP+ 3 m Direct Attach Copper Cable (JG327A)
HPE X24040 G QSFP+ to QSFP+ 5 m Direct Attach Copper Cable (JG328A)
HPE X24040 G QSFP+ to 4x10 G SFP+ 1 m Direct Attach Copper Splitter Cable (JG329A)
HPE X24040 G QSFP+ to 4x10 G SFP+ 3 m Direct Attach Copper Splitter Cable (JG330A)
HPE X24040 G QSFP+ to 4x10 G SFP+ 5 m Direct Attach Copper Splitter Cable (JG331A)
HPE X2A040 G QSFP+ to QSFP+ 7 m Active Optical Cable (JL287A)
HPE X2A040 G QSFP+ to QSFP+ 10 m Active Optical Cable (JL288A)
HPE X2A040 G QSFP+ to QSFP+ 20 m Active Optical Cable (JL289A)
HPE X13010 G SFP+ LC SR Transceiver (JD092B)
HPE X13010 G SFP+ LC LRM Transceiver (JD093B)
HPE X13010 G SFP+ LC LR Transceiver (JD094B)
HPE X13010 G SFP+ LC ER 40 km Transceiver (JG234A)
HPE X13010 G SFP+ LC ER 40 km Transceiver (JG234A)
HPE X13010 G SFP+ LC LH 80 km Transceiver (JG915A)
HPE X13010 G SFP+ LC LH80 Tunable Transceiver (JL250A)
HPE X24010 G SFP+ to SFP+ 065 m Direct Attach Copper Cable (JD095C)
HPE X24010 G SFP+ to SFP+ 12 m Direct Attach Copper Cable (JD096C)
HPE X24010 G SFP+ to SFP+ 3 m Direct Attach Copper Cable (JD097C)
HPE X24010 G SFP+ to SFP+ 5 m Direct Attach Copper Cable (JG081C)
HPE X24010 G SFP+ SFP+ 7 m Direct Attach Copper Cable (JC784C)
HPE X2A010 G SFP+ to SFP+ 7 m Active Optical Cable (JL290A)
HPE X2A010 G SFP+ to SFP+ 10 m Active Optical Cable (JL291A)
HPE X2A010 G SFP+ to SFP+ 20 m Active Optical Cable (JL292A)
Power supplyHPE 58x0AF 650W AC Power Supply (JC680A)
HPE FlexFabric 5930-32QSFP+ Switch (JG726A)HPE X711 Front (port side) to Back (power side) Airflow High Volume Fan Tray (JG552A)