The HPE FlexFabric 5900CP Switch Series is a family of high-density, ultra-low-latency, converged, top-of-rack (ToR) switches that
is part of the Hewlett Packard Enterprise (HPE) FlexNetwork architecture's HPE FlexFabric solution.
Ideally suited for deployment at
Switch Series is also powerful enough for deployment at the data center core layer of medium
in virtualized applications and
server traffic, customers now require ToR switch innovations that will meet their needs for
higher-performance server connectivity, convergence of Ethernet and storage traffic, the capability to handle virtual environments,
and ultra
The 5900CP has been tested in typical and popular storage configurations with HPE 3PAR storage solutions. Tested and
supported deployments include FC, FCoE, iSCSI and NAS storage environments. They also include single and multiple h
configurations as well as connecting to 3rd party FC SANs.The FlexFabric 5900CP is SDN
protocol.
Key features
• Cut-through with ultra-low-latency and wire speed
Features and benefits
the server access layer of medium or large enterprise data centers, the HPE FlexFabric 5900CP
-sized enterprises. With the increase
server-to-
-low-latency all in a single device.
op
-enabled and supports OpenFlow
• HPE Intelligent Resilient Fabric (IRF) for virtualization and two-tier architecture
• High 1GbE/10GbE and 4Gbps/8Gbps FC ToR port density with 40 GbE uplinks
• IPv4/IPv6 dual stach with full L2/L3 features
• Convergence ready with Native Fiber Channel, DCB, FCoE, and TRILL
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
2
Quality of Service (QoS)
), and Weighted Random
Data center optimized
through and nonblocking architecture delivers low latency (~1 microsecond for 10GbE) for very demanding enterprise
monitoring, and restart; the OS also allows individual software modules to be upgraded for higher availability and supports
performance remote backup
Manageability
• Powerful QoS features:
− Flexible classification
− Feature support
• Flexible high port density
the HPE 5900CP Switch Series enables scaling of the server edge with 1 GbE and 10GbE as well as 4Gbps and 8Gbps
Fiber Channel ToR deployments to new heights with high-density 48-port solutions delivered in a 1RU design; the high
server port density is backed by 40 GbE QSFP+ uplinks to deliver the availability of needed bandwidth for demanding
applications; each 40 GbE QSFP+ port can also be configured as four 10GbE ports by using a 40-GbE-to-10GbE splitter
cable
•High-performance switching
cutapplications; the switch delivers high-performance switching capacity and wire-speed packet forwarding
• Higher scalability
HPE Intelligent Resilient Fabric (IRF) technology simplifies the architecture of server access networks; up to nine HPE
5900 switches can be combined to deliver unmatched scalability of virtualized access layer switches and flatter two-tier
networks using IRF, which reduces cost and complexity
• Advanced modular operating system
Comware v7 software's modular design and multiple processes bring native high stability, independent process
creates traffic classes based on access control lists (ACLs), IEEE 802.1p precedence, IP, and DSCP or Type of
Service (ToS) precedence; supports filter, redirect, mirror, remark, and logging
provides support for Strict Priority Queuing (SP), Weighted Fair Queuing (WFQ), Weighted Deficit Round Robin
(WDRR), SP+WDRR together, configurable buffers, Explicit Congestion Notification (ECN
Early Detection (WRED)
enhanced serviceability functions like hitless software upgrades with single-chassis ISSU
• TRILL and EVB/VEPA:
transparent Interconnection of Lots of Links (TRILL) is supported to increase the scale of enterprise data centers; Edge
Virtual Bridging with Virtual Ethernet Port Aggregator (EVB/VEPA) provides connectivity into the virtual environment for
a data center-ready environment
• Reversible airflow
enhanced for data center hot-cold aisle deployment with reversible airflow—for either front-to-back or back-to-front
airflow
•Redundant fans and power supplies
1+1 internal redundant and hot-pluggable power supplies and dual fan trays enhance reliability and availability
• Lower OPEX and greener data center
provide reversible airflow and advanced chassis power management
• Data Center Bridging (DCB) protocols
provides support for IEEE 802.1Qbb Priority Flow Control (PFC), Data Center Bridging Exchange (DCBX), and IEEE
802.1Qaz Enhanced Transmission Selection (ETS) for converged applications
•FCoE support
provides support for Fibre Channel over Ethernet (FCoE), including expansion, fabric, trunk VF and N ports, and
aggregation of E-port and N-port virtualization; fabric services such as name server, registered state change notification,
and login services; per-VSAN fabric services, FSPF, soft and hard zoning, Fibre Channel traceroute, ping, debugging, and
FIP snooping
• Jumbo frames
with frame sizes of up to 10,000 bytes on Gigabit Ethernet and 10-Gigabit ports, allows highand disaster-recovery services to be enabled
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
3
• Full-featured console
Resiliency and high availability
based networks
provides complete control of the switch with a familiar CLI
• Troubleshooting
− Ingress and egress port monitoring
enable network problem solving
• Multiple configuration files
• sFlow (RFC 3176)
• SNMP v1, v2c and v3
• Out-of-band interface
• Remote configuration and management
• ISSU and hot patching
• Autoconfiguration
• Network Time Protocol (NTP) and Secure Network Time Protocol (SNTP)
− Traceroute and ping
enable testing of network connectivity
allow multiple configuration files to be stored to a flash image
provides wire-speed traffic accounting and monitoring
facilitate centralized discovery, monitoring, and secure management of networking devices
isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
is available through a secure command-line interface (CLI) over Telnet and SSH; Role-Based Access Control (RBAC)
provides multiple levels of access; Configuration Rollback and multiple configurations on the flash provide ease of
operation; remote visibility is provided with sFlow and SNMP v1/v2/v3, and is fully supported in HPE Intelligent
Management Center (IMC)
provides hitless software upgrades with single-unit In Services Software Upgrade (ISSU) and hitless patching of the
modular operating system
provides automatic configuration via DHCP autoconfiguration
synchronize timekeeping among distributed time servers and clients; keep consistent timekeeping among all clockdependent devices within the network so that the devices can provide diverse applications based on the consistent time
enables an HPE FlexFabric to deliver resilient, scalable, and secured data center networks for physical and virtualized
environments; groups up to nine HPE 5900 switches in an IRF configuration, allowing them to be configured and
managed as a single switch with a single IP address; simplifies ToR deployment and management, reducing data center
deployment and operating expenses
• IEEE 802.1w Rapid Convergence Spanning Tree Protocol
increases network uptime through faster recovery from failed links
• IEEE 802.1s Multiple Spanning Tree
provides high link availability in multiple VLAN environments by allowing multiple spanning trees
• Virtual Router Redundancy Protocol (VRRP)
allows groups of two routers to dynamically back each other up to create highly available routed environments
• Hitless patch upgrades
allows patches and new service features to be installed without restarting the equipment, increasing network uptime and
facilitating maintenance
Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Device Link Detection Protocol (DLDP)
monitors link connectivity and shuts down ports at both ends if unidirectional traffic is detected, preventing loops in STP-
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
4
• Graceful restart
Layer 2 switching
Policy; IPv6 IGMP Snooping provides Layer 2 optimization of
Layer 3 services
determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection
Layer 3 routin
MD5 authentication for increased security and graceful restart for faster failure recovery
allows routers to indicate to others their capability to maintain a routing table during a temporary shutdown and
significantly reduces convergence times upon recovery; supports OSPF, BGP, and IS-IS
•MAC-based VLAN
provides granular control and security; uses RADIUS to map a MAC address/user to specific VLANs
• Address Resolution Protocol (ARP)
supports static, dynamic, and reverse ARP and ARP proxy
•Flow Control
IEEE 802.3x Flow Control provides intelligent congestion management via PAUSE frames
• Ethernet Link Aggregation
provides IEEE 802.3ad Link Aggregation of up to 128 groups of 16 ports; support for LACP, LACP Local Forwarding First,
and LACP Short-time provides a fast, resilient environment that is ideal for the data center
provides support for 4,096 VLANs based on port, MAC address, IPv4 subnet, protocol, and guest VLAN; supports VLAN
mapping
• IGMP support
provides support for IGMP Snooping, Fast-Leave, and Groupmulticast traffic
•DHCP support at Layer 2
provides full DHCP Snooping support for DHCP Snooping Option 82, DHCP Relay Option 82, DHCP Snooping Trust, and
DHCP Snooping Item Backup
• Address Resolution Protocol (ARP)
• Dynamic Host Configuration Protocol (DHCP)
• Operations, administration and maintenance (OAM) support
• Virtual Router Redundancy Protocol (VRRP) and VRRP Extended
• Policy-based routing
• Equal-Cost Multipath (ECMP)
• Layer 3 IPv4 routing
• Open shortest path first (OSPF)
of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a
Layer 2 network
simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation
across subnets
provides support for Connectivity Fault Management (IEEE 802.1AG) and Ethernet in the First Mile (IEEE 802.3AH);
provides additional monitoring that can be used for fast fault detection and recovery
g
allow quick failover of router ports
makes routing decisions based on policies set by the network administrator
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, BGP, and IS-IS
delivers faster convergence; uses this link-state routing Interior Gateway Protocol (IGP), which supports ECMP, NSSA, and
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
5
•Border Gateway Protocol 4 (BGP-4)
IS routing and extended
Additional information
Management
dependent devices within the network so that the devices can provide diverse applications based on the consistent time
delivers an implementation of the Exterior Gateway Protocol (EGP) utilizing path vectors; uses TCP for enhanced
reliability for the route discovery process; reduces bandwidth consumption by advertising only incremental updates;
supports extensive policies for increased flexibility; scales to very large networks
•Intermediate system to intermediate system (IS-IS)
uses a path vector Interior Gateway Protocol (IGP), which is defined by the ISO organization for ISby IETF RFC 1195 to operate in both TCP/IP and the OSI reference model (Integrated IS-IS)
• Static IPv6 routing
provides simple manually configured IPv6 routing
• Dual IP stack
maintains separate stacks for IPv4 and IPv6 to ease the transition from an IPv4-only network to an IPv6-only network
design
•Routing Information Protocol next generation (RIPng)
extends RIPv2 to support IPv6 addressing
• OSPFv3
provides OSPF support for IPv6
• BGP+
extends BGP-4 to support Multiprotocol BGP (MBGP), including support for IPv6 addressing
•IS-IS for IPv6
extends IS-IS to support IPv6 addressing
•IPv6 tunneling
allows IPv6 packets to traverse IPv4-only networks by encapsulating the IPv6 packet into a standard IPv4 packet;
supports manually configured, 6to4, and Intra-Site Automatic Tunnel Addressing Protocol (ISATAP) tunnels; is an
important element for the transition from IPv4 to IPv6
• Policy routing
allows custom filters for increased performance and security; supports ACLs, IP prefix, AS paths, community lists, and
aggregate policies
• Bidirectional Forwarding Detection (BFD)
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and
IRF
• Multicast Routing
provides robust support of multicast protocols
• Layer 3 IPv6 routing
provides routing of IPv6 at media speed; supports static routing, RIPng, OSPFv3, BGP4+ for IPv6, and IS-ISv6
• Green IT and power
improves energy efficiency through the use of the latest advances in silicon development; shuts off unused ports and
utilizes variable-speed fans, reducing energy costs
• Low power consumption
is rated to have one of the lowest power usages in the industry by Miercom independent tests
• USB support
− File copy
• Multiple configuration files
stores easily to the flash image
•SNMPv1, v2c, and v3
facilitate centralized discovery, monitoring, and secure management of networking devices
• Network Time Protocol (NTP)
synchronizes timekeeping among distributed time servers and clients; keeps timekeeping consistent among all clock-
allows users to copy switch files to and from a USB flash drive
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
6
• Out-of-band interface
Security
ring based on source/destination IP address/subnet and source/destination TCP/UDP port number
controls port-based access for authentication and accountability
isolates management traffic from user data plane traffic for complete isolation and total reachability, no matter what
happens in the data plane
• Port mirroring
enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
• Remote configuration and management
is available through a command-line interface (CLI)
• IEEE 802.1AB Link Layer Discovery Protocol (LLDP)
advertises and receives management information from adjacent devices on a network, facilitating easy mapping by
network management applications
• sFlow (RFC 3176)
provides scalable ASIC-based wirespeed network monitoring and accounting with no impact on network performance; this
allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and
real-time network monitoring purposes
• Command authorization
leverages RADIUS to link a custom list of CLI commands to an individual network administrator's login; an audit trail
documents activity
• Dual flash images
provides independent primary and secondary operating system files for backup while upgrading
•Command-line interface (CLI)
provides a secure, easy-to-use CLI for configuring the module via SSH or a switch console; provides direct real-time
session visibility
• Logging
provides local and remote logging of events via SNMP (v2c and v3) and syslog; provides log throttling and log filtering to
reduce the number of log events generated
• Management interface control
provides management access through a modem port and terminal interface, as well as in-band and out-of-band Ethernet
ports; provides access through terminal interface, Telnet, or secure shell (SSH)
• Industry-standard CLI with a hierarchical structure
reduces training time and expenses, and increases productivity in multivendor installations
• Management security
restricts access to critical configuration commands; offers multiple privilege levels with password protection; ACLs provide
Telnet and SNMP access; local and remote syslog capabilities allow logging of all access
• Information center
provides a central repository for system and network information; aggregates all logs, traps, and debugging information
generated by the system and maintains them in order of severity; outputs the network information to multiple channels
based on user-defined rules
• Network management
HPE Intelligent Management Center (IMC) centrally configures, updates, monitors, and troubleshoots
• Remote intelligent mirroring
mirrors ingress/egress ACL-selected traffic from a switch port or VLAN to a local or remote switch port anywhere on the
network
• Access control lists (ACLs)
• RADIUS/TACACS+
• Secure shell
• IEEE 802.1X and RADIUS network logins
provide IP Layer 3 filte
eases switch management security administration by using a password authentication server
encrypts all transmitted data for secure remote CLI access over IP networks
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Overview
7
• Port security
Conve
defines a standard extension of LLDP that stores values for parameters such as QoS and VLAN to automatically configure
Warranty and support
; for details on the software releases
HPE Recommended Options have the best performance, value and availability.
Recommended Options
workloads and market segments. Fully integrated into the ProLiant management and security experience, Recommended Options
provide the best fit with ti
Extended Options
requiring the utmost in performance or value.
Options represent great value and performance but typically have a longer lead
allows access only to specified MAC addresses, which can be learned or specified by the administrator
rgence
•LLDP-MED (Media Endpoint Discovery)
network devices such as IP phones
•1-year Warranty
see http://www.hpe.com/networking/warrantysummary
product purchase.
• Software releases
to find software for your product, refer to http://www.hpe.com/networking/support
available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary
for warranty and support information included with your
have been selected by Hewlett Packard Enterprise experts to provide the right technology for a range of
mely availability. View the list for your region.
provide an extended catalog of products tailored for customers in specific markets or with specific workloads,
Fully integrated into the ProLiant management and security experience, Extended
-time.
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Configuration
8
Build To Order:
BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable solution.
Note 5
The following 40G Transceivers install into this Module: (Use #0D1 or #B01 if switch is
CTO)
HPE X140 40G QSFP+ LC BiDi 100m MM Transceiver
JL251A
Note 6
The following 10G/40G Transceivers install into this switch: (Use #0D1 or #B01 quoted
to switch if switch is CTO) - if applicable)
HPE X2A0 10G SFP+ to SFP+ 7m Active Optical Cable
JL290A
HPE X2A0 10G SFP+ to SFP+ 10m Active Optical Cable
JL291A
HPE X2A0 10G SFP+ to SFP+ 20m Active Optical Cable
JL292A
HPE X2A0 40G QSFP+ to QSFP+ 7m Active Optical Cable
JL287A
HPE X2A0 40G QSFP+ to QSFP+ 10m Active Optical Cable
JL288A
HPE X2A0 40G QSFP+ to QSFP+ 20m Active Optical Cable
JL289A
Note 10
If the Switch Chassis is to be Box Level Factory Integrated (CTO), Then the #0D1 is required on the Switch
Chassis and integrated to the JG505A
per SSP)
HPE Premier Flex MPO/MPO OM4 100m (12ft) Cable (Recommended)
H6Z30A
Internal Power Supplies
(JG838A) System (std 0 // max 2) User Selection (min 1 // max 2) per switch
(JH302A and JH303A) System (std 2 // max 2) User Selection (min 0 // max 0) per switch
HPE 58x0AF 650W AC Power Supply
JC680A
• includes 1 x c13, 300w
See Configuration
PDU Cable NA/MEX/TW/JP
JC680A#B2B
• C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC680A#B2C
• C15 PDU Jumper Cord (ROW)
HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W AC Power Supply
JG900A
•
See Configuration
NOTE:
PDU Cable NA/MEX/TW/JP
JG900A#B2B
• C15 PDU Jumper Cord (ROW)
High Volt Switch/Router to Wall Power Cord
JG900A#B2E
• C15 PDU Jumper Cord (ROW)
HPE A58x0AF Back (Power Side) to Front (Port Side) Airflow 300W DC Power Supply
JG901A
See Configuration
NOTE: 1, 3, 5
C15 PDU Jumper Cord (NA/MEX/TW/JP)
NOTE: 1, 2, 3
1, 3, 4
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Configuration
15
HPE FlexFabric Switch 650W 48V Hot Plug NEBS-compliant DC Power Supply
JH336A
See Configuration
NOTE: 1, 3
Configuration Rules
Note 1
If 2 power supplies are selected they must be the same Sku number.
Note 2
Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) . (See Localization
Menu)
REMARK: When Switches/Routers are Factory Racked, Then #B2B, or #B2C should be the Defaulted Power
Cable option on the Switches/Routers.
Note 3
Only supported on JG838A
Note 4
Localization (Wall Power Cord) required on orders without #B2B, #B2C (PDU Power Cord) or #B2E. (See
Localization Menu)
REMARK: When Switches/Routers are Factory Racked, Then #B2B, #B2C should be the Defaulted Power
Cable option on the Switches/Routers
Note 5
Watson Only - Add "(NEBS)" after the description on the PS table.
Remarks:
Drop down under power supply should offer the following options and results:
Switch/Router/Power Supply to PDU Power Cord
#B2C ROW. (Watson Default B2B or B2C for Rack Level CTO)
Switch/Router/Power Supply to Wall Power Cord
CTO)
High Volt Power Electrical Module to Wall Power Cord
in North America, Mexico,
Taiwan, and Japan)
NOTE* Switch JG838A should default selection of Power Supply as JC680A but allow selection of JG900A
and JG901A.
Switch Options
Fan Trays
(JG838A) System (std 0 // max 2) User Selection (min 2 // max 2) per switch
(JH302A and JH303A) System (std 2 // max 2) User Selection (min 0 // max 0) per switch
HPE 58x0AF Back (Power Side) to Front (Port Side) Airflow Fan Tray
JC682A
See Configuration
NOTE: 1,3
HPE 58x0AF Front (Port Side) to Back (Power Side) Airflow Fan Tray
JC683A
See Configuration
NOTE: 1,3
HPE X711 Front (Port Side) to Back (Power Side) Airflow High Volume Fan Tray
JG552A
See Configuration
- #B2B in North America, Mexico, Taiwan, and Japan or
- Localized Option (Watson Default for BTO and Box Level
- #B2E Option. (Offered only
NOTE: 1,4
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Configuration
16
HPE X712 Back (Power Side) to Front (Port Side) Airflow High Volume Fan Tray
JG553A
See Configuration
NOTE: 1,4
Configuration Rules
Note 1
Fan Trays cannot be mixed in the same switch enclosure
Note 3
Only supported on JG838A.
Note 4
Only supported on JG838A.
Remarks:
Watson Blue Text:
If there is any empty space below the switch in a rack when using Back to Front Fan Trays, JC682A
or JG553A, the rack will receive an Air Plenum kit that takes up 1U of additional space in the rack.
The Air P
Integration. The Air Plenum Kit is a non
Factory Rack Level Integration.
Tamper Evidence Labels
System (std 0 // max 1) User Selection (min 0 // max 1)
HPE 12mm x 60mm Tamper Evidence (30) Labels
JG585A
•
See Configuration
NOTE:
Configuration Rules
Note 1
If selected with a CTO Switch Solution, Quantity 1 of JG719A#B01 must also be ordered.
Remarks
Each JG719A would use 1 of JG585A.
lenum kit is not required on fully configured racks. This only applies for CTO Rack Level
-saleable SKU, and is brought in automatically for CTO
2 power supply slots
1 minimum power supply required (ordered separately)
Fan tray
2 fan tray slots
direction airflow fan trays to function properly. The system should not be operated with only
than two minutes. The system should not be operated outside of the temperature range of 32°F (0°C)
to 113°F (45°C). Failure to comply with these operating requirements may void the product warranty.
Physical characteristics
Dimensions
17.32(w) x 25.98(d) x 1.72(h) in (43.99 x 65.99 x 4.37 cm)
Idle power is the actual power consumption of the device with no ports
pped), 100% traffic, all ports plugged in, and all
modules populated.
Safety
UL 60950-1; EN 60825-1 Safety of Laser Products-Part 1; EN 60825-2 Safety of Laser Products-Part
Subchapter J; NOM; ROHS Compliance
Emissions
VCCI Class A; EN 55022 Class A; ICES-003 Class A; ANSI C63.4 2003; AS/NZS CISPR 22 Class A; EN
47, Part 15) Class A
Immunity
Generic
ETSI EN 300 386 V1.3.3
EN
EN 55024:1998+ A1:2001 + A2:2003
slots
1 RJ-45 out-of-band management port
The customer must order fan trays, as fan trays are not included with the switch. This system requires
two sameone fan tray for more than 24 hours. The system should not be operated without a fan tray for more
< 1.5 µs (64-byte packets)
connected.
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure
with fully loaded PoE (if equi
2; IEC 60950-1; CAN/CSA-C22.2 No. 60950-1; Anatel; ULAR; GOST; EN 60950-1/A11; FDA 21 CFR
61000-3-2:2006; EN 61000-3-3:1995 +A1:2001+A2:2005; EMC Directive 2004/108/EC; FCC (CFR
details on the service-level descriptions and product numbers. For details about services and response
times in your area, please contact your local Hewlett Packard Enterprise sales office.
General protocols
IEEE 802.1D MAC Bridges
IEEE 802.1p Priority
IEEE 802.1Q VLANs
IEEE 802.1s Multiple Spanning Trees
IEEE 802.1w Rapid Reconfiguration of Spanning
73 SNMP-Target MIB
-
t
-BGP-4 for IPv6
ressing Architecture
-
-MPD MIB
-Notification MIB
-User based-SM MIB
-View based-ACM MIB
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Technical Specifications
19
IEEE 802.3ad Link Aggregation Control Protocol
Protocol
LLDP-EXT-DOT1-MIB
LLDP
LLDP
Network management
RFC 3164 BSD syslog Protocol
OSPF
RFC 1587 OSPF NSSA
R
RFC 3101 OSPF NSSA
RFC 3137 OSPF Stub Router Advertisement
RFC 3623 Graceful OSPF Restart
RFC 4577 OSPF as the Provider/Customer Edge
Protocol for BGP/MPLS IP Virtual Private Networks
(VPNs)
RFC 4811 OSPF Out
Resynchronization
R
RFC 4813 OSPF Link
QoS/CoS
IEEE 802.1p (CoS)
RFC 2475 DiffServ Architecture
RFC 2597 DiffServ Assured Forwarding (AF)
RFC 3247 Supplemental Information for the New
Definition of the EF PHB (Expedited Forwardin
Per
RFC 3260 New Terminology and Clarifications for
DiffServ
Security
Access Control Lists (ACLs)
SSHv2 Secure Shell
(LACP)
IEEE 802.3ae 10-Gigabit Ethernet
IEEE 802.3ag Ethernet OAM
IEEE 802.3ah Ethernet in First Mile over Point to
Point Fiber – EFMF
IEEE 802.3x Flow Control
RFC 768 UDP
RFC 783 TFTP Protocol (revision 2)
RFC 791 IP
RFC 792 ICMP
RFC 793 TCP
RFC 826 ARP
RFC 854 TELNET
RFC 856 TELNET
RFC 868 Time Protocol
RFC 896 Congestion Control in IP/TCP
Internetworks
RFC 950 Internet Standard Subnetting Procedure
RFC 1027 Proxy ARP
RFC 1058 RIPv1
RFC 1091 Telnet Terminal-Type Option
RFC 1141 Incremental updating of the Internet
checksum
RFC 1142 OSI IS-IS Intra-domain Routing Protocol
RFC 1191 Path MTU discovery
RFC 1213 Management Information Base for
Network Management of TCP/IP-based internets
RFC 1253 (OSPF v2)
RFC 1531 Dynamic Host Configuration Protocol
RFC 1533 DHCP Options and BOOTP Vendor
Extensions
RFC 1534 DHCP/BOOTP Interoperation
RFC 1541 DHCP
RFC 1591 DNS (client only)
RFC 1624 Incremental Internet Checksum
RFC 1723 RIP v2
RFC 1812 IPv4 Routing
RFC 2030 Simple Network Time Protocol (SNTP)
v4
RFC 2131 DHCP
RFC 2236 IGMP Snooping
RFC 2338 VRRP
RFC 2453 RIPv2
RFC 2581 TCP Congestion Control
RFC 2644 Directed Broadcast Control
RFC 2767 Dual Stacks IPv4 & IPv6
RFC 3046 DHCP Relay Agent Information Option
RFC 3768 Virtual Router Redundancy Protocol
(VRRP)
RFC 4250 The Secure Shell (SSH) Protocol
Assigned Numbers
RFC 4251 The Secure Shell (SSH) Protocol
Architecture
RFC 4252 The Secure Shell (SSH) Authentication
-EXT-DOT3-MIB
-MIB
FC 2328 OSPFv2
-of-Band LSDB
FC 4812 OSPF Restart Signaling
-Local Signaling
g
-Hop Behavior)
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Technical Specifications
20
RFC 4253 The Secure Shell (SSH) Transport Layer
Address Autoconfiguration in IPv6
Protocol
RFC 4254 The Secure Shell (SSH) Connection
Protocol
RFC 4364 BGP/MPLS IP Virtual Private Networks
(VPNs)
RFC 4419 Diffie-Hellman Group Exchange for the
Secure Shell (SSH) Transport Layer Protocol
RFC 4594 Configuration Guidelines for DiffServ
Service Classes
RFC 4941 Privacy Extensions for Stateless
Page
QuickSpecs
HPE FlexFabric 5900CP Switch Series
Accessories
21
HPE FlexFabric 5900CP Switch Series bundles and accessories
Bundles
HPE FlexFabric 5900CP 48XG 4QSFP+ Front-to-Back AC Switch Bundle
JH302A
Included in this bundle: (1) FlexFabric 5900CP 48XG 4QSFP+ Switch (JG838A), (2) HPE 58x0AF Front (port
side) to Back (power side) Airflow Fan Tray (JC683A), and (2)
(JC680A)
HPE FlexFabric 5900CP 48XG 4QSFP+ Back-to-Front AC Switch Bundle
JH303A
Included in this bundle: (1) FlexFabric 5900CP 48XG 4QSFP+ Switch (JG838A), (2) HPE 58x0AF Back
(power side) to Front (port side) Airflow Fan T
(JC680A)
Transceivers
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X120 1G SFP LC BX 10-U Transceiver
JD098B
HPE X120 1G SFP LC BX 10-D Transceiver
JD099B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC SR Data Center Transceiver
JL437A
HPE X130 10G SFP+ LC LRM Transceiver
JD093B
HPE X130 10G SFP+ LC LRM Data Center Transceiver
JL438A
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC LR Data Center Transceiver
JL439A
HPE X130 10G SFP+ LC ER 40km Transceiver
JG234A
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable