HPE JC101A Getting Started Guide

QuickSpecs
HPE FlexFabric 5800 Switch Series

Overview

1
HPE FlexFabric 5800 Switch Series
HPE FlexFabric 5800 24G PoE+ Switch (JC099B)
HPE FlexFabric 5800 24G Switch (JC100B)
HPE FlexFabric 5800 24G SFP 1-slot Switch (JC103B)
HPE FlexFabric 5800 48G PoE+ 1-slot Switch (JC104B)
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
2
HPE FlexFabric 5800 48G 1-slot Switch (JC105B)
HPE FlexFabric 5800 48G POE+ 2-slot Switch (JC101B)
HPE FlexFabric 5800AF 48G Switch (JG225B)
Models
HPE FlexFabric 5800 24G PoE+ Switch
JC099B
HPE FlexFabric 5800 24G Switch
JC100B
HPE FlexFabric 5800 24G SFP 1-slot Switch
JC103B
HPE FlexFabric 5800 48G PoE+ 1-slot Switch
JC104B
HPE FlexFabric 5800 48G 1-slot Switch
JC105B
HPE FlexFabric 5800 48G POE+ 2-slot Switch
JC101B
HPE FlexFabric 5800AF 48G Switch
JG225B
Key features
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
3
For enterprise edge, distribution, data center
Product overview
The HPE FlexFabric 5800 Switch Series offer an unmatched combination of Gigabit and 10-Gigabit Ethernet port density, high­availability architecture, and full Layer 2 and Layer 3 dual performance on all p Protocol (RRPP), which allow local or geographically distributed HPE 5800 switches to be interconnected for higher resiliency performance. Avail switches are built on open standards and include an open application architecture (OAA) module slot that enables flexible deployment options for new services. These versatile switches are ideal for use in the network core of buildings or departments, or as high-performance switches in the convergence layer or network edge of enterprise campus networks
Features and benefits
Quality of Service (QoS)
based topology; provides consistent application performance for applications such
Management
Cut-through design with low latency
Support for up to 84 ports
OAA module for flexible deployment
Redundant, hot-swappable power supplies, fans
Powerful QoS feature
creates traffic classes based on access control lists (ACLs), IEEE 802.1p precedence, IP, and DSCP or Type of Service (ToS) precedence; supports filter, redirect, mirror, or remark; supports the following congestion actions: strict priority (SP) queuing, weighted round robin (WRR), weighted fair queuing (WFQ), weighted random early discard (WRED), weighted deficit round robin (WDRR), and SP+WDRR
Integrated network services
with support for open application architecture (OAA) modules, extends and integrates application capability into the network
Ring Resiliency Protection Protocol (RRPP)
provides fast recovery for ring Ethernet­as VoIP
-stack IPv4 and IPv6 capabilities. In addition to wire-speed line-rate
orts, the switches include patented Intelligent Resilient Fabric (IRF) technology and Rapid Ring Protection
and
able in PoE and non-PoE models as well as 1 RU and 2 RU form factor configurations, HPE FlexFabric 5800
Remote configuration and management
is available through a secure Web browser or a command-line interface (CLI)
IEEE 802.1AB LLDP discovery
advertises and receives management information from adjacent devices on a network, facilitating easy mapping by network management applications
USB support:
File copy
allows users to copy switch files to and from a USB flash drive
DHCP options:
DNS Relay and SMTP Redirection
DHCP: Server (RFC 2131), Client, and Option-82 Relay (RFC 3046)
sFlow
provides scalable, ASIC-based network monitoring and accounting; this allows network operators to gather a variety of sophisticated network statistics and information for capacity planning and real-time network monitoring purposes
SNMPv1, v2c, and v3
facilitate centralized discovery, monitoring, and secure management of networking devices
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
4
Network Time Protocol (NTP)
Connectivity
evices such as IP phones, wireless access points,
Performance
Resiliency and high availability
front airflow for hot/cold aisles, rear rack mounts,
Manageability
provide advanced monitoring and reporting capabilities for statistics, history, alarms, and events
synchronizes timekeeping among distributed time servers and clients; keeps consistent timekeeping among all clock­dependent devices within the network so that the devices can provide diverse applications based on the consistent time
High-density port connectivity
supports up to 84 1-Gigabit ports per unit (612 per stack)
Auto-MDIX
automatically adjusts for straight-through or crossover cables on all 10/100 ports
Jumbo frames
on Gigabit Ethernet and 10-Gigabit ports, jumbo frames of 9k size allow high-performance remote backup and disaster­recovery services
IEEE 802.3af Power over Ethernet (PoE)
provides up to 15.4 W per port to IEEE 802.3af-compliant PoE-powered d and security cameras
IEEE 802.3at Power over Ethernet (PoE+) support
simplifies deployment and dramatically reduces installation costs by helping to eliminate the time and cost involved in supplying local power at each access point location
IPv6 native support
IPv6 host
enables switches to be managed and deployed at the IPv6 network's edge
Dual stack (IPv4/IPv6)
transitions from IPv4 to IPv6, supporting connectivity for both protocols
MLD snooping
forwards IPv6 multicast traffic to the appropriate interface
IPv6 ACL/QoS
supports ACL and QoS for IPv6 network traffic, preventing traffic flooding
IPv6 routing
supports IPv6 static routes and IPv6 versions of RIP, OSPF, IS-IS, and BGP routing protocols
Hardware-based wire-speed access control lists (ACLs)
feature-rich ACL implementation (TCAM-based) helps provide high levels of security and ease of administration without impacting network performance
Unique versatile architecture
supports the best of both fixed-port and modular configurations
Data center–optimized design
the HPE 5800AF-48G Switch (JG225B) supports front-to-back/back-to­and redundant hot-swappable AC or DC power and fans
Full-featured console
provides complete control of the switch with a familiar command-line interface (CLI)
Web interface
allows configuration of the switch from any Web browser on the network
RMON and sFlow
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
5
Multiple configuration files
Layer 2 switching
Layer 3 services
determines the MAC address of another IP host in the same subnet; supports static ARPs; gratuitous ARP allows detection
Layer 3 routing
provides routing of IPv6 at media speed; supports static routes, RIPng, OSPFv3, IS-ISv6, and BGP4+
allow multiple configuration files to be stored to a flash image
Troubleshooting
GARP VLAN Registration Protocol:
32K MAC addresses
4,094 port-based VLANs
IEEE 802.1ad QinQ and Selective QinQ
Gigabit Ethernet port aggregation
10 GbE port aggregation
Spanning Tree/MSTP, RSTP, and STP Root Guard
IPFIX/sFlow
Spanning Tree Protocols (STP, MSTP, and RSTP) and STP root guard
Ingress and egress port monitoring
enable network problem solving
Traceroute and ping
enable testing of network connectivity
Virtual cable tests
provide visibility to cable problems
allows automatic learning and dynamic assignment of VLANs
provide access to many Layer 2 devices
provide security between workgroups
increase the scalability of an Ethernet network by providing a hierarchical structure; connect multiple LANs on a high­speed campus or metro network
allows grouping of ports to increase overall data throughput to a remote device
allows grouping of ports to increase overall data throughput to a remote device
prevent network loops
allows traffic sampling
helps prevent network loops; up to 32 MSTP instances available
Address Resolution Protocol (ARP)
Dynamic Host Configuration Protocol (DHCP)
Layer 3 IPv4 routing
RIP and RIPng support
OSPF and OSPFv3 support
IS-IS and IS-ISv6 support
Layer 3 IPv6 routing
of duplicate IP addresses; proxy ARP allows normal ARP operation between subnets or when subnets are separated by a Layer 2 network
simplifies the management of large IP networks and supports client and server; DHCP Relay enables DHCP operation across subnets
provides routing of IPv4 at media speed; supports static routes, RIP and RIPv2, OSPF, IS-IS, and BGP
provides complete support of RIP for both IPv4 and IPv6
provides complete support of OSPF for both IPv4 and IPv6
provides complete support of IS-IS for both IPv4 and IPv6
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
6
Bidirectional Forwarding Detection (BFD)
Security
enables link connectivity monitoring and reduces network convergence time for RIP, OSPF, BGP, IS-IS, VRRP, MPLS, and IRF
Virtual Router Redundancy Protocol (VRRP) and VRRP Extended
allow quick failover of router ports
Policy-based routing
makes routing decisions based on policies set by the network administrator
IGMPv1, v2, and v3
allow individual hosts to be registered on a particular VLAN
PIM-SSM, PIM-DM, and PIM-SM (for IPv4 and IPv6)
support IP Multicast address management and inhibition of DoS attacks
Equal-Cost Multipath (ECMP)
enables multiple equal-cost links in a routing environment to increase link redundancy and scale bandwidth
NEW MPLS support
provides extended support of MPLS, including MPLS VPNs and MPLS Traffic Engineering (MPLS TE)
NEW VPLS support
provides extended support of VPLS for data center to data center communication at Layer 2; provides support of hierarchical VPLS for scalability
Unicast Reverse Path Forwarding (URPF)
allows normal packets to be forwarded correctly, but discards the attaching packet due to lack of reverse path route or incorrect inbound interface; prevents source spoofing and distributed attacks; supports distributed UFPF
Defense-in-depth security
provides integrated and distributed security enforcement that can be managed from a central location, such as the HPE Intelligent Management Center (IMC)
Advanced processor queuing mechanism
helps prevent denial-of-service (DoS) attacks, while DHCP snooping helps ensure that devices can only receive an IP address from a legitimate DHCP server on the network
IEEE 802.1X-based dynamic delivery of QoS, ACLs, and VLANs
allows complete control over user network access
Guest VLAN
similar to IEEE 802.1X, it provides a browser-based environment to authenticated clients
Port isolation
secures and adds privacy, and prevents malicious attackers from obtaining user information
MAC-based authentication
allows or denies access to the switch based on client MAC address
HTTPS management
provides secure Web management
Multi-Customer Edge (MCE)-Multicast Virtual Routing and Forwarding (MVRF)
provide MPLS Edge router support
Public Key Infrastructure (PKI)
is used to control access
RADIUS/HWTACACS
eases switch management security administration by using a password authentication server
Secure Shell (SSHv2)
encrypts all transmitted data for secure, remote CLI access over IP networks
IP Source Guard
helps prevent IP spoofing attacks; filters packets on a per-port basis, which prevents illegal packets from being forwarded
Access control lists (ACLs)
helps provide high levels of security and ease of administration; 6k ingress entries and 1k egress entries (IPv4 and IPv6)
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Overview
7
Convergence
LLDP that stores values for parameters such as QoS and VLAN to configure automatically
Monitor and diagnostics
Additional information
Warranty and support
; for details on the software releases
Voice VLAN
Internet Group Management Protocol (IGMP)
Protocol Independent Multicast (PIM)
LLDP-MED (Media Endpoint Discovery)
automatically assigns VLAN and priority for IP phones, simplifying network configuration and maintenance
is used by IP hosts to establish and maintain multicast groups; supports v1, v2, and v3; utilizes Any-Source Multicast (ASM) or Source-Specific Multicast (SSM) to manage IPv4 multicast networks
defines modes of Internet multicasting to allow one-to-many and many-to-many transmission of information; supports PIM Dense Mode (DM), Sparse Mode (SM), and Source-Specific Multicast(SSM)
defines a standard extension of network devices such as IP phones
Port mirroring
enables traffic on a port to be simultaneously sent to a network analyzer for monitoring
OAM (IEEE 802.3ah)
operational, administration and maintenance (OAM) management capabilities detects data link layer problems that occurred in the "last mile"; monitors the status of the link between the two devices
CFD (IEEE 802.1ag)
connectivity fault detection (CFD) provides a Layer 2 link OAM mechanism used for link connectivity detection and fault locating
HPE Intelligent Resilient Fabric (IRF)
Creates virtual resilient switching fabrics, where two or more switches perform as a single Layer 2 switch and
OAA modules
Switches do not have to be co-located and can be part of a disaster-recovery system
Servers or switches can be attached using standard LACP for automatic load balancing and high availability
Simplifies network operation by eliminating the complexity of Spanning Tree Protocol, ECMP, or VRRP
support wireless network management and high-performance security applications; leverage network infrastructure investment
Green IT and power
use the latest advances in silicon development, shut off unused ports, and use variable-speed fans to improve energy efficiency
Higher scalability with IRF
simplifies the architecture of server access networks and reduces cost and complexity; up to nine 5800 Switches can be combined to deliver unmatched scalability of virtualized access layer switches and flatter, two-tier FlexFabric networks
Layer 3 router
Limited Lifetime warranty
See http://www.hpe.com/networking/warrantysummary product purchase.
Software releases
to find software for your product, refer to http://www.hpe.com/networking/support available with your product purchase, refer to http://www.hpe.com/networking/warrantysummary
for warranty and support information included with your
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series

Configuration

8
Build To Order:
BTO is a standalone unit with no integration. BTO products ship standalone are not part of a CTO or Rack-Shippable solution.
Standard Switch Chassis
HPE FlexFabric 5800 24G Switch
JC100B
24 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC100B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC100B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC100B#B2E
HPE FlexFabric 5800 24G PoE+ Switch
JC099B
24 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC099B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC099B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC099B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800 24G SFP 1-slot Switch
JC103B
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
NEMA L6-20P Cord (NA/MEX/JP/TW)
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
Configuration
NOTE:1, 3, 7
Configuration
NOTE:1, 3, 7
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
9
24 100/1000 SFP ports
See
HPE FlexFabric 5800 48G 1-slot Switch
JC105B
48 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC105B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC105B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC105B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800AF 48G Switch
JG225B
48 RJ-45 autosensing 10/100/1000 ports
See
HPE FlexFabric 5800 48G PoE+ 1-slot Switch
JC104B
48 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC104B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
min=0 \ max=24 SFP Transceivers
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Must select min 1 Power Supply
1U - Height
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U- Height
Configuration
NOTE:1, 4
Configuration
NOTE:1, 3, 7
6 fixed 1000/10000 SFP+ ports
min=0 \ max=6 SFP+ Transceivers
Must select min 1 Power Supply
Must select min 2 Fan Trays
1U- Height
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
Configuration
NOTE:1
Configuration
NOTE:1, 3, 7
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
10
PDU Cable ROW
JC104B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC104B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800 48G POE+ 2-slot Switch
JC101B
48 RJ-45 autosensing 10/100/1000 ports
See
Configuration Rules
Note 1
The following Transceivers install into this switch:
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC LRM Transceiver
JD093B
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC SR Data Center Transceiver
JL437A
HPE X130 10G SFP+ LC LRM Data Center Transceiver
JL438A
HPE X130 10G SFP+ LC LR Data Center Transceiver
JL439A
HPE X130 10G SFP+ LC ER 40km Transceiver
JG234A
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH70 Transceiver
JD063B
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HPE X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Campus-Cable
JH693A
HPE X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Campus-Cable
JH694A
HPE X240 10G SFP+ to SFP+ 3m Direct Attach Copper Campus-Cable
JH695A
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
JG081C
Note 3
Localization required on orders without #B2B, #B2C or #B2E options.
Note 4
The following Transceivers install into this Switch:
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X110 100M SFP LC LH40 Transceiver
JD090A
2 extended module slot
4 fixed 1000 SFP ports
min=0 \ max=4 SFP Transceivers
Must select min 1 Power Supply
2U - Height
Configuration
NOTE:4
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
11
HPE X110 100M SFP LC LH80 Transceiver
JD091A
HPE X115 100M SFP LC FX Transceiver
JD102B
HPE X110 100M SFP LC LX Transceiver
JD120B
HPE X115 100M SFP LC BX 10-U Transceiver
JD100A
HPE X115 100M SFP LC BX 10-D Transceiver
JD101A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 7
#B2E is Offered only NA, Mexico, Taiwan, and Japan.
Box Level Integration CTO Models
CTO Solution Sku
HPE FlexFabric 58xx Configure-to-order Switch Solution
JG478A
SSP trigger sku
CTO Base Sku
HPE FlexFabric 5800 24G Switch
JC100B
24 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC100B#B2B
PDU Cable ROW
JC100B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC100B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800 24G PoE+ Switch
JC099B
24 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC099B#B2B
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
C15 PDU Jumper Cord (NA/MEX/TW/JP)
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
Configuration
NOTE:1, 3, 9,
10, 11
Configuration
NOTE:1, 3, 9,
10, 11
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
12
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC099B#B2C
C15 PDU Jumper Cord (ROW)
High Volt Switch to Wall Power Cord
JC099B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800 24G SFP 1-slot Switch
JC103B
24 100/1000 SFP ports
See
HPE FlexFabric 5800 48G 1-slot Switch
JC105B
48 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC105B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC105B#B2C
High Volt Switch to Wall Power Cord
JC105B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800AF 48G Switch
JG225B
48 RJ-45 autosensing 10/100/1000 ports
See
HPE FlexFabric 5800 48G PoE+ 1-slot Switch
JC104B
min=0 \ max=24 SFP Transceivers
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Must select min 1 Power Supply
1U - Height
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U- Height
C15 PDU Jumper Cord (ROW)
Configuration
NOTE:1, 4, 5,
10
Configuration
NOTE:1, 3, 9,
10, 11
6 fixed 1000/10000 SFP+ ports (min=0 \ max=6 SFP+ Transceivers)
Must select min 1 Power Supply
Must select min 2 Fan Trays
1U - Height
Configuration
NOTE:1, 8, 10
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
13
48 RJ-45 autosensing 10/100/1000 ports
See
PDU Cable NA/MEX/TW/JP
JC104B#B2B
C15 PDU ROW
JC104B#B2C
High Volt Switch to Wall Power Cord
JC104B#B2E
NEMA L6-20P Cord (NA/MEX/JP/TW)
HPE FlexFabric 5800 48G POE+ 2-slot Switch
JC101B
See
Configuration Rules
Note 1
The following Transceivers install into this switch: (Use #0D1 or #B01 if switch is CTO) If Applicable -
HPE X130 10G SFP+ LC SR Transceiver
JD092B
HPE X130 10G SFP+ LC LRM Transceiver
JD093B
HPE X130 10G SFP+ LC LR Transceiver
JD094B
HPE X130 10G SFP+ LC SR Data Center Transceiver
JL437A
HPE X130 10G SFP+ LC LRM Data Center Transceiver
JL438A
HPE X130 10G SFP+ LC LR Data Center Transceiver
JL439A
HPE X130 10G SFP+ LC ER 40km Transceiver
JG234A
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X125 1G SFP LC LH70 Transceiver
JD063B
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE FlexNetwork X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Cable
JD095C
HPE FlexNetwork X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Cable
JD096C
HPE FlexNetwork X240 10G SFP+ to SFP+ 3m Direct Attach Copper Cable
JD097C
HPE X240 10G SFP+ to SFP+ 0.65m Direct Attach Copper Campus-Cable
JH693A
HPE X240 10G SFP+ to SFP+ 1.2m Direct Attach Copper Campus-Cable
JH694A
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
C15 PDU Jumper Cord (NA/MEX/TW/JP)
C15 PDU Jumper Cord (ROW)
48 RJ-45 autosensing 10/100/1000 ports
2 extended module slot
4 fixed 1000 SFP ports
min=0 \ max=4 SFP Transceivers
Must select min 1 Power Supply
2U - Height
Configuration
NOTE:1, 3, 9,
10, 11
Configuration
NOTE:4, 5,10
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
14
HPE X240 10G SFP+ to SFP+ 3m Direct Attach Copper Campus-Cable
JH695A
HPE FlexNetwork X240 10G SFP+ to SFP+ 5m Direct Attach Copper Cable
JG081C
Note 3
Localization required on orders without #B2B, #B2C or #B2E options.
Note 4
The following Transceivers install into this Switch: (Use #0D1 if switch is CTO) If Applicable -
HPE X125 1G SFP LC LH40 1310nm Transceiver
JD061A
HPE X120 1G SFP LC LH40 1550nm Transceiver
JD062A
HPE X120 1G SFP RJ45 T Transceiver
JD089B
HPE X120 1G SFP LC SX Transceiver
JD118B
HPE X120 1G SFP LC LX Transceiver
JD119B
HPE X110 100M SFP LC LH40 Transceiver
JD090A
HPE X110 100M SFP LC LH80 Transceiver
JD091A
HPE X115 100M SFP LC FX Transceiver
JD102B
HPE X110 100M SFP LC LX Transceiver
JD120B
HPE X115 100M SFP LC BX 10-U Transceiver
JD100A
HPE X115 100M SFP LC BX 10-D Transceiver
JD101A
HPE X125 1G SFP LC LH70 Transceiver
JD063B
Note 5
If this Switch is selected at least one of these Power Supply with #0D1 is required:
HPE 5800 300W AC Power Supply
JC087A
HPE 5800 750W AC Power Supply
JC089A
Note 8 If this Switch is selected at least one of these Power Supply with #0D1 is required:
HPE 58x0AF 650W AC Power Supply
JC680A
Note 9
B2E is Offered only in . NA, Mexico, Taiwan, and Japan.
Note 10
If the Switch Chassis is to be Box Level Factory Integrated (CTO), Then the #0D1 is required on the Switch Chassis and integrated to the JG478A SSP)
Note 11
If this Switch is selected, Then a Minimum of 1 factory integrated accessory, OR Factory Service, must be ordered and integrated to CTO chassis. See Menu below, option must have a #0D1 to be integrated to the CTO Chassis.
Rack Level Integration CTO Models
Standard Switch Chassis
HPE FlexFabric 5800 24G Switch
JC100B
24 RJ-45 autosensing 10/100/1000 ports
See Configuration
PDU Cable NA/MEX/TW/JP
JC100B#B2B
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
- HPE FlexFabric 58xx Configure-to-order Switch Solution. (Min 1/Max 1 Switch per
NOTE:1, 3, 10
Page
QuickSpecs
HPE FlexFabric 5800 Switch Series
Configuration
15
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC100B#B2C
C15 PDU Jumper Cord (ROW)
HPE FlexFabric 5800 24G PoE+ Switch
JC099B
24 RJ-45 autosensing 10/100/1000 ports
See Configuration
PDU Cable NA/MEX/TW/JP
JC099B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC099B#B2C
C15 PDU Jumper Cord (ROW)
HPE FlexFabric 5800 24G SFP 1-slot Switch
JC103B
24 100/1000 SFP ports
See Configuration
HPE FlexFabric 5800 48G 1-slot Switch
JC105B
48 RJ-45 autosensing 10/100/1000 ports
See Configuration
PDU Cable NA/MEX/TW/JP
JC105B#B2B
C15 PDU Jumper Cord (NA/MEX/TW/JP)
PDU Cable ROW
JC105B#B2C
C15 PDU Jumper Cord (ROW)
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U - Height
min=0 \ max=24 SFP Transceivers
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Must select min 1 Power Supply
1U - Height
NOTE:1, 3, 10
NOTE:1, 4, 10
1 extended module slot
4 fixed 1000/10000 SFP+ ports
min=0 \ max=4 SFP+ Transceivers
Power Supply included
1U- Height
NOTE:1, 3, 10
Page
Loading...
+ 34 hidden pages