QuickSpecs
HP 600 Redundant and External Power Supply
HP 600 Redundant and External Power Supply
HP 600 Redundant and External Power SupplyHP 600 Redundant and External Power Supply
Overview
Models
Models
ModelsModels
HP 600 Redundant and External Power Supply
Product overview
Product overview
Product overviewProduct overview
The HP 600 Redundant and External Power Supply (RPS/EPS) has two different power supplies embedded: one for 12 V and the other one for 50 V. The 12 V power supply is called a redundant power supply (RPS) and the 50 V power supply is called the external PoE power supply (EPS). The RPS has six ports offering redundant power to any one of up to six 2600 switches. The EPS has two ports and can power up to 24 Power over Ethernet (PoE) ports with full 15.4 W PoE power, if only one of the EPS ports is used. Alternatively, it can simultaneously power up to 12 ports with full 15.4 W of PoE power on each of two switches if both EPS ports are used. The pair of EPS ports can supply up to 408 W of PoE power.
Features and benefits
Features and benefits
Features and benefitsFeatures and benefits
Additional information
Additional information
Additional informationAdditional information
Power distribution on an "as-needed" basis
Power distribution on an "as-needed" basis
Power distribution on an "as-needed" basisPower distribution on an "as-needed" basis switch fails, it provides backup power in less than 1 millisecond RPS device prioritization
RPS device prioritization
RPS device prioritizationRPS device prioritization provided to the highest-priority switch; RPS port 1 has the highest priority, whereas port 6 has the lowest priority Redundant switch power
Redundant switch power
Redundant switch powerRedundant switch power supply in a switch in case of loss of AC power or a fault condition External switch power
External switch power
External switch powerExternal switch power to 15.4 W per port on 48-port stackable Hot-plugging
Hot-plugging
Hot-pluggingHot-plugging Supports HP chassis and stackable products
Supports HP chassis and stackable products
Supports HP chassis and stackable productsSupports HP chassis and stackable products switches Cables included
Cables included
Cables includedCables included
: supports changing the configuration of an RPS or EPS cable while the device is powered
: includes two 2-meter EPS cables and six 1.26-meter RPS cables
: if the internal power supply of more than one of the connected switches fails, redundant power is
(six ports): provides redundant power to any one of up to six switch products, backing up the power
(two ports): provides external power to up to two PoE switch devices through two EPS ports; supports up
: monitors power supplies from connected switch or switches; when power from a
: power supply units can be configured to support both chassis and stackable
J8168A
DA - 11992 Worldwide — Version 12 — November 2, 2011
Page 1
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Technical Specifications
HP 600 Redundant and
HP 600 Redundant and
HP 600 Redundant andHP 600 Redundant and External Power Supply
External Power Supply
External Power SupplyExternal Power Supply (J8168A)
Ports
Ports
PortsPorts
Physical
Physical
PhysicalPhysical characteristics
characteristics
characteristicscharacteristics
Mounting
Mounting
MountingMounting
Environment
Environment
EnvironmentEnvironment
Electrical characteristics
Electrical characteristics
Electrical characteristicsElectrical characteristics
Safety
Safety
SafetySafety Emissions
Emissions
EmissionsEmissions Immunity
Immunity
ImmunityImmunity
HP 600 Redundant and External Power Supply
HP 600 Redundant and External Power Supply
HP 600 Redundant and External Power SupplyHP 600 Redundant and External Power Supply
6 redundant power supply ports Restrictions: Each port can provide redundant +12 V power to a connected switch; only one port can provide power at a given time
2 external power supply ports Restrictions: Provides 50 VDC external PoE to up to two ProCurve switch devices; provides max. of 408 W full power to one device, and half power (204 W each) if connected to two devices
Dimensions
Dimensions
DimensionsDimensions
Weight
Weight
WeightWeight 1U rack-mountable and wall-mountable enclosure using standard mounting
hardware Operating temperature
Operating temperature
Operating temperatureOperating temperature Operating relative
Operating relative
Operating relativeOperating relative humidity
humidity
humidityhumidity Nonoperating/Storage
Nonoperating/Storage
Nonoperating/StorageNonoperating/Storage temperature
temperature
temperaturetemperature Nonoperating/Storage
Nonoperating/Storage
Nonoperating/StorageNonoperating/Storage relative humidity
relative humidity
relative humidityrelative humidity Altitude
Altitude
AltitudeAltitude Acoustic
Acoustic
AcousticAcoustic
Description
Description
DescriptionDescription
Voltage
Voltage
VoltageVoltage Current
Current
CurrentCurrent Maximum power rating
Maximum power rating
Maximum power ratingMaximum power rating RPS power
RPS power
RPS powerRPS power PoE power
PoE power
PoE powerPoE power Frequency
Frequency
FrequencyFrequency Notes
Notes
NotesNotes
CSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950 FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A EN
EN
ENEN ESD
ESD
ESDESD Radiated
Radiated
RadiatedRadiated EFT/Burst
EFT/Burst
EFT/BurstEFT/Burst
Surge
Surge
SurgeSurge
12.83(d) x 17.44(w) x 1.73(h) in. (32.59 x 44.3 x 4.39 cm) (1U height)
11.78 lb. (5.34 kg), Fully loaded
32°F to 131°F (0°C to 55°C) 15% to 95% @ 104°F (40°C), noncondensing
-40°F to 158°F (-40°C to 70°C)
15% to 95% @ 149°F (65°C), noncondensing
up to 15,000 ft. (4.6 km) Noise emission LwA=59.2 dB at virtual
workspace, according to DIN 45635 T.19 The unit automatically adjusts to any voltage
between 100-240 V and either 50 or 60 Hz 100-240 VAC 9/5 A 800 W 180 W 408 W 50/60 Hz Maximum power rating and maximum heat
dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
EN 55024, CISPR 24 IEC 61000-4-2; 4 kV CD, 8 kV AD IEC 61000-4-3; 3 V/m IEC 61000-4-4; 1.0 kV (power line), 0.05 kV
(signal line) IEC 61000-4-5; 1 kV/2 kV AC
DA - 11992 Worldwide — Version 12 — November 2, 2011