QuickSpecs
Compaq R6000 Uninterruptible Power System
Compaq R6000 Uninterruptible Power System
Compaq R6000 Uninterruptible Power SystemCompaq R6000 Uninterruptible Power System
Overview
The Latest Innovation from Compaq
The Latest Innovation from Compaq
The Latest Innovation from CompaqThe Latest Innovation from Compaq
More critical equipment supported in rack space with space-saving design (6U) and more accurate load qualification
Greater system uptime with Extended Run-time Modules (ERMs)
Enhanced system flexibility with five load segments and additional support for Compaq UPS option cards
Benefits at a Glance
Benefits at a Glance
Benefits at a GlanceBenefits at a Glance
Enterprise-wide intelligent manageability with independently controllable load segments and bundled Compaq Power Management Software
Ultimate, long-term battery reliability with Compaq Enhanced Battery Management
System expandability and manageability with Compaq UPS option cards
Ease of serviceability with a service Bypass switch and hot-swappable batteries
Backed by a limited, three-year warranty, Compaq Pre Failure warranty, and $25,000 load protection guaranty. Certain restrictions and exclusions
apply. $25,000 load protection guarantee supported by original equipment manufacturer. Consult the Customer Support Center for details. For more
information about Compaq UPSs or other Compaq products, contact your authorized Compaq reseller or visit our Web site at
More Critical Equipment Supported
More Critical Equipment Supported
More Critical Equipment SupportedMore Critical Equipment Supported
Rated at 6000VA/6000W, the Compaq R6000 UPS achieves a unity power rating. As a unity rated UPS, the Compaq R6000 delivers more true power - as
measured in Watts - than non-unity rated UPSs. The Compaq R6000 UPS delivers more accurate load qualification, allowing you to support a greater
number of today's enterprise computing Power Factor Corrected (PFC) equipment.
www.compaq.com
.
Efficient Design Saves Rack Space
Efficient Design Saves Rack Space
Efficient Design Saves Rack SpaceEfficient Design Saves Rack Space
The Compaq R6000 occupies only 6U (10.5 inches) of valuable rack real estate. The state-of-the art power processing system design of the Compaq R6000
has an unsurpassed power density of 1kW per 1U of rack space.
Investment Protection with Compaq Enhanced Battery Management
Investment Protection with Compaq Enhanced Battery Management
Investment Protection with Compaq Enhanced Battery ManagementInvestment Protection with Compaq Enhanced Battery Management
The Compaq R6000 UPS incorporates Enhanced Battery Management-an exclusive, patented technology that doubles battery service life, optimizes battery
recharge time, and provides advance notice of pending battery failure. With Enhanced Battery Management, you have a lower total cost of ownership and
receive the best in the industry protection for your critical equipment.
Increases System Uptime with Extended Runtime Modules and Hot-Swappable Batteries
Increases System Uptime with Extended Runtime Modules and Hot-Swappable Batteries
Increases System Uptime with Extended Runtime Modules and Hot-Swappable BatteriesIncreases System Uptime with Extended Runtime Modules and Hot-Swappable Batteries
The Compaq R6000 UPS is equipped with hot-swappable batteries, so you can replace batteries without powering down the connected equipment. The rackmounted Extended Runtime Modules occupy 3U (5.25 inches) of rack space. The Compaq R6000 UPS supports up to two Extended Runtime Modules.
More Flexibility with Compaq UPS Option Cards and Additional Load Segments
More Flexibility with Compaq UPS Option Cards and Additional Load Segments
More Flexibility with Compaq UPS Option Cards and Additional Load SegmentsMore Flexibility with Compaq UPS Option Cards and Additional Load Segments
Compaq UPS option cards seamlessly integrate into the back bezel of your Compaq R6000 UPS. The Compaq Multi-Server Card facilitates direct
communication with up to three servers, eliminating the need for multiple UPSs. The Compaq Scalable Card enables multiple UPSs to work together and to
be monitored as one logical UPS providing scalability and field upgradability. Equipped with two option slots, the Compaq R6000 UPS can support the
Compaq Multi-Server and Scalable Cards simultaneously.
With five load segments, you have the flexibility to configure scheduled startups and shutdowns, as well as independently control separate load segments.
With the bundled Compaq Power Management Software, the Compaq R6000 UPS can be configured to extend the runtime for more critical devices.
SNMP-EN Adapter acts as a user interface in a network environment, allowing communication between the UPS and the server, when the SNMP-based power
management software, Compaq OnliNet Centro is installed. Network managers can perform basic SNMP queries to determine specific power information,
such as battery capacity, on demand from the UPS. The SNMP-EN Adapter also provides unsolicited communications to the network management software
in the event of a power failure or a critical UPS condition.
Compaq Quality
Compaq Quality
Compaq QualityCompaq Quality
Backed by extensive testing, product improvement and an unsurpassed warranty, you are guaranteed the highest level of system protection and performance
with your Compaq R6000 UPS.
It supports V.42, MNP 2-4, MNP 10, MNP 10EC, and V.42bis/MNP 5, providing the most advanced error correction and data compression available.
DA - 10284 Worldwide — Version 7 — September 18, 2003
Page 1
RETIRED: Retired products sold prior to the November 1, 2015 separation of Hewlett-Packard Company into Hewlett Packard Enterprise Company and HP Inc. may
have older product names and model numbers that differ from current models.
QuickSpecs
Specifications
Electrical Input
Electrical Input
Electrical InputElectrical Input
Electrical Output
Electrical Output
Electrical OutputElectrical Output
Battery
Battery
BatteryBattery
Communications
Communications
CommunicationsCommunications
Environmental and Safety
Environmental and Safety
Environmental and SafetyEnvironmental and Safety
Voltage
Voltage Range
Extended Voltage Range
Frequency
Connection
Power Factor
Inrush Current
Online Efficiency
REPC
Power Out (VA/Watts)
Voltage Range (online)
Voltage Range (on battery)
Wave Form
Frequency
Connections
Max Current
Output Protection
Sleep Mode (User-
Configurable)
Type
Extended batteries
Backup Time
Recharge Time
Extended Battery Recharge Time
Serial Ports
Option Cards
User LEDs
Front Panel Controls
LCD
Operating Temperature
Transit Temperature
Storage Temperature
Humidity (Operating)
Humidity (Non-operating)
Operating Altitude
Non-Operating Altitude
Audible Noise
Safety Markings
Safety Certifications
EMC Markings
Emissions
Immunity
Surge Suppression
REPO Port
Compaq R6000 Uninterruptible Power System
Compaq R6000 Uninterruptible Power System
Compaq R6000 Uninterruptible Power SystemCompaq R6000 Uninterruptible Power System
200, 208, 220, 230 & 240 user-selectable; see Model Selection Guide for default voltage
settings
± 20% of nominal voltage
160-288V
50/60 Hz, ± 3 Hz (± 5 Hz with extended voltage range)
Hardwired
Approx. same as connected equipment
< 250A for one cycle
96%
Remote Emergency Power-Off disables AC power to load
6000/6000
± 10% of nominal voltage
± 5% of nominal voltage (-10% at low battery)
Sine Wave
Same as input (± 0.5% during battery operation)
(3) IEC-320, 16A and (12) IEC-320, 10A; divided into 5 Load Segments
29A at 208 Vac; 26A at 230 Vacl 30A at 200 Vac
Resettable circuit breaker (One 10 Amp for each load segment)
With < 8% load, UPS shuts down in 5 minutes to prevent unnecessary battery drain, sleep
mode is disabled as default from factory
Maintenance-free, sealed, valve regulated lead acid (VRLA),
(28, 12V 5 amp)
Maximum of 2 Extended Run Modules
See Backup Times table
< 3 hours to 80% usable capacity; < 48 hours for complete recharge
< 10 hours to 80% usable capacity
(2) Serial communication ports for intelligent power management software and Compaq
Option Cards
Multi-Server UPS Card, Scalable UPS Card, and the SNMP-EN Adapter for rear panel
option slots
Normal Operation (green), On Battery (yellow), On Bypass (yellow), and Alarm (red)
On button, Standby button, & Test/Reset/Alarm Silence button
Two-line LCD with three button control
50° to 104°F/10° to 40°C (77°F/25°C for optimal performance)
-4° to 131°F/-20° to 55°C
32° to 77°C /0°C to 25°C
20% to 80% (non-condensing)
5% to 95%
0 to 10,000 feet/0 to 3,048 m
0 to 30,000 feet/0 to 9,144 m
55 dBA at 1 meter
FCS, UL, CSA, VDE, NEMKO, FIMKO, DEMKO, SEMKO, NOM
UL1778; CSA22.2 No.107.1,No.107.2,No.950; CB Bulletin No.86AI; EN50091-1;
EN60950; EMKO-TSE207/95; NOM-019-SCFI-1993
FCC; CISPR; VCCI; CE
FCC CFR 47, Part 15 Class A, EN50091-2
IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5
Conforms to IEEE 587B and ANSI C62.41
Meets NEC code 645-11